Motion Sensor Accuracy under Controlled and Free-Living Conditions
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
PURPOSE: Two studies were conducted to examine the concurrent accuracy of the Yamax SW-200 (YAM), Omron HJ-105 (OM), and Sportline 330 (SL) pedometers, as well as a CSA accelerometer. METHODS: In study 1, motion sensor performance was evaluated against actual (observed) steps taken during 5-min bouts at five different treadmill speeds (54, 67, 80, 94, and 107 m x min) using a two-way repeated measures ANOVA (instrument x speed). Additionally, the direction and magnitude of motion sensor error was examined. In study 2, pedometer performance during 24 h of free-living was evaluated against the steps detected by the CSA criterion. The direction and magnitude of pedometer error was also examined in the free-living condition. RESULTS: In study 1, the SL showed significant differences from actual steps taken at all treadmill speeds (P < 0.05). Further, the absolute value of percent error was greatest for the SL at all treadmill speeds. At the slowest treadmill speed (54 m x min), the absolute value of percent error increased for the YAM and OM. In study 2, only the SL detected fewer steps than the CSA criterion (P < 0.05). The YAM demonstrated the lowest absolute value of percent error under free-living conditions. CONCLUSIONS: Different brands of motion sensors detect steps differently; therefore, caution must be used when comparing step counts between studies that have employed different brands of motion sensors. Taking into consideration the results of both studies and the initial walking test used for instrument screening purposes, it appears that, of the three pedometers tested, the YAM pedometer is most consistently accurate under both controlled and free-living conditions. Future research must consider presenting motion sensor accuracy in absolute terms so that the magnitude of error is not underestimated.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy and Reliability of 10 Pedometers for Measuring Steps over a 400-m Walk
SCHNEIDER, P. L., CROUTER, S. E., LUKAJIC, O., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000089342.96098.c4 · Cited by 633
Accuracy of five electronic pedometers for measuring distance walked
BASSETT, D. R., AINSWORTH, B. E., LEGGETT, S. R., MATHIEN, C. A., MAIN, J. A., HUNTER, D. C., & DUNCAN, G. E. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199608000-00019 · Cited by 552
Challenges and Opportunities for Measuring Physical Activity in Sedentary Adults
Tudor-Locke, C. E., & Myers, A. M. (2001) · Sports Medicine · doi:10.2165/00007256-200131020-00002 · Cited by 519
Self-citationTudor-Locke, C. E., & Myers, A. M. (2001) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2001.10608926 · Cited by 518
Self-citationValidity of accelerometry for the assessment of moderate intensity physical activity in the field
HENDELMAN, D., MILLER, K., BAGGETT, C., DEBOLD, E., & FREEDSON, P. (2000) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200009001-00002 · Cited by 516
Comparison of pedometer and accelerometer measures of free-living physical activity
TUDOR-LOCKE, C., AINSWORTH, B. E., THOMPSON, R. W., & MATTHEWS, C. E. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200212000-00027 · Cited by 386
Self-citationComparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360
Self-citationReexamination of Validity and Reliability of the CSA Monitor in Walking and Running
BRAGE, S., WEDDERKOPP, N., FRANKS, P. W., BO ANDERSEN, L., & FROBERG, K. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000079078.62035.ec · Cited by 347
Nichols, J. F., Morgan, C. G., Chabot, L. E., Sallis, J. F., & Calfas, K. J. (2000) · Research Quarterly for Exercise and Sport · doi:10.1080/02701367.2000.10608878 · Cited by 203
Step activity monitor: Increased accuracy in quantifying ambulatory activity
Shepherd, E. F., Toloza, E., McClung, C. D., & Schmalzried, T. P. (1999) · Journal of Orthopaedic Research · doi:10.1002/jor.1100170512 · Cited by 182
Cited by
Global Physical Activity Questionnaire (GPAQ): Nine Country Reliability and Validity Study
Bull, F. C., Maslin, T. S., & Armstrong, T. (2009) · Journal of Physical Activity and Health · doi:10.1123/jpah.6.6.790 · Cited by 1,777
How many steps/day are enough? for adults
Tudor-Locke, C., Craig, C. L., Brown, W. J., Clemes, S. A., De Cocker, K., Giles-Corti, B., Hatano, Y., Inoue, S., Matsudo, S. M., Mutrie, N., et al. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-79 · Cited by 1,087
Self-citationHow many steps/day are enough? For older adults and special populations
Tudor-Locke, C., Craig, C. L., Aoyagi, Y., Bell, R. C., Croteau, K. A., De Bourdeaudhuij, I., Ewald, B., Gardner, A. W., Hatano, Y., Lutes, L. D., et al. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-80 · Cited by 1,076
Self-citationStrath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Assessment of Physical Activity and Energy Expenditure: An Overview of Objective Measures
Hills, A. P., Mokhtar, N., & Byrne, N. M. (2014) · Frontiers in Nutrition · doi:10.3389/fnut.2014.00005 · Cited by 575
Revisiting "How Many Steps Are Enough?"
TUDOR-LOCKE, C., HATANO, Y., PANGRAZI, R. P., & KANG, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31817c7133 · Cited by 511
Self-citationThe validity and reliability of a novel activity monitor as a measure of walking
Ryan, C. G., Grant, P. M., Tigbe, W. W., & Granat, M. H. (2006) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.027276 · Cited by 490
How many days of pedometer monitoring predict weekly physical activity in adults?
TUDORLOCKE, C., BURKETT, L., REIS, J., AINSWORTH, B., MACERA, C., & WILSON, D. (2005) · Preventive Medicine · doi:10.1016/j.ypmed.2004.06.003 · Cited by 479
Self-citationFerguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468
Translating Physical Activity Recommendations into a Pedometer-Based Step Goal
Marshall, S. J., Levy, S. S., Tudor-Locke, C. E., Kolkhorst, F. W., Wooten, K. M., Ji, M., Macera, C. A., & Ainsworth, B. E. (2009) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2009.01.021 · Cited by 447
Self-citationDowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
“The majority of articles compared activity monitor determined energy expenditure with DLW [73, 77, 80, 96, 105, 274, 275, 277, 278, 280, 281, 285, 292, 293, 295, 296, 300, 303–305, 311, 313, 317, 323], while activity monitor determined steps [119, 271, 283, 287, 289, 298, 299, 306, 307, 314, 315, 318], distance travel…”
A step-defined sedentary lifestyle index: <5000 steps/day
Tudor-Locke, C., Craig, C. L., Thyfault, J. P., & Spence, J. C. (2013) · Applied Physiology, Nutrition, and Metabolism · doi:10.1139/apnm-2012-0235 · Cited by 384
Self-citationTudor-Locke, C., Brashear, M. M., Johnson, W. D., & Katzmarzyk, P. T. (2010) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-7-60 · Cited by 375
Self-citationPrescribing exercise as preventive therapy
Warburton, D. E. R. (2006) · Canadian Medical Association Journal · doi:10.1503/cmaj.1040750 · Cited by 374
Accelerometer-Determined Steps per Day inUS Adults
TUDOR-LOCKE, C., JOHNSON, W. D., & KATZMARZYK, P. T. (2009) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e318199885c · Cited by 355
Self-citationAccelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Wang, J. B., Cadmus-Bertram, L. A., Natarajan, L., White, M. M., Madanat, H., Nichols, J. F., Ayala, G. X., & Pierce, J. P. (2015) · Telemedicine and e-Health · doi:10.1089/tmj.2014.0176 · Cited by 308
Activity-Monitor Accuracy in Measuring Step Number and Cadence in Community-Dwelling Older Adults
Grant, P. M., Dall, P. M., Mitchell, S. L., & Granat, M. H. (2008) · Journal of Aging and Physical Activity · doi:10.1123/japa.16.2.201 · Cited by 297
“These findings agree with those from previous studies in which slow walking speeds were found to compromise the accuracy of this spring-levered pedometer (Crouter et al., 2005; Le Masurier et al., 2004; Le Masurier & Tudor-Locke, 2003; Melanson et al., 2004; Ryan et al., 2006; Swartz et al., 2003).”
ResultSpring-Levered versus Piezo-Electric Pedometer Accuracy in Overweight and Obese Adults
CROUTER, S. E., SCHNEIDER, P. L., & BASSETT, D. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181677.36658.a8 · Cited by 295
Harris, T. J., Owen, C. G., Victor, C. R., Adams, R., & Cook, D. G. (2009) · British Journal of Sports Medicine · doi:10.1136/bjsm.2008.048033 · Cited by 236
“The step-count function exactly counts observed steps at all treadmill speeds, whereas pedometers may under-record at low speeds.(12) Most PA in older people is walking-based and hence activity counts and stepcounts are likely to be highly correlated.”
BackgroundUsing Cadence to Study Free-Living Ambulatory Behaviour
Tudor-Locke, C., & Rowe, D. A. (2012) · Sports Medicine · doi:10.2165/11599170-000000000-00000 · Cited by 231
Self-citationUsing Activity Monitors to Measure Physical Activity in Free-Living Conditions
Berlin, J. E., Storti, K. L., & Brach, J. S. (2006) · Physical Therapy · doi:10.1093/ptj/86.8.1137 · Cited by 209
Accuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury
Fulk, G. D., Combs, S. A., Danks, K. A., Nirider, C. D., Raja, B., & Reisman, D. S. (2014) · Physical Therapy · doi:10.2522/ptj.20120525 · Cited by 182
Lagerros, Y. T., & Lagiou, P. (2007) · European Journal of Epidemiology · doi:10.1007/s10654-007-9154-x · Cited by 178
“It measures walking-related activity, but the length of a step varies with setting and different brands seem to detect steps differently [45].”
BackgroundLloyd, A. B., Lubans, D. R., Plotnikoff, R. C., Collins, C. E., & Morgan, P. J. (2014) · Appetite · doi:10.1016/j.appet.2014.04.010 · Cited by 177
The Accuracy of Pedometer Steps and Time during Walking in Children
BEETS, M. W., PATTON, M. M., & EDWARDS, S. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000155395.49960.31 · Cited by 166
Video-Recorded Validation of Wearable Step Counters under Free-living Conditions
TOTH, L. P., PARK, S., SPRINGER, C. M., FEYERABEND, M. D., STEEVES, J. A., & BASSETT, D. R. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001569 · Cited by 154
Cain, K. L., Conway, T. L., Adams, M. A., Husak, L. E., & Sallis, J. F. (2013) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-10-51 · Cited by 161
“error) compared with direct observation [8].”
ResultÉvaluation de la qualité des podomètres commerciaux
Tudor-Locke, C., Sisson, S. B., Lee, S. M., Craig, C. L., Plotnikoff, R. C., & Bauman, A. (2006) · Canadian Journal of Public Health · doi:10.1007/bf03405359 · Cited by 142
Self-citationComparison of two waist-mounted and two ankle-mounted electronic pedometers
Karabulut, M., Crouter, S. E., & Bassett, D. R. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0018-3 · Cited by 139
Measuring physical activity during pregnancy
Harrison, C. L., Thompson, R. G., Teede, H. J., & Lombard, C. B. (2011) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-8-19 · Cited by 139
King, A. C., Bickmore, T. W., Campero, M. I., Pruitt, L. A., & Yin, J. L. (2013) · Journal of Health Communication · doi:10.1080/10810730.2013.798374 · Cited by 114
Accelerometer-Determined Steps/Day and Metabolic Syndrome
Sisson, S. B., Camhi, S. M., Church, T. S., Tudor-Locke, C., Johnson, W. D., & Katzmarzyk, P. T. (2010) · American Journal of Preventive Medicine · doi:10.1016/j.amepre.2010.02.015 · Cited by 116
Self-citationNormative Steps/Day Values for Older Adults: NHANES 2005-2006
Tudor-Locke, C., Schuna, J. M., Barreira, T. V., Mire, E. F., Broyles, S. T., Katzmarzyk, P. T., & Johnson, W. D. (2013) · The Journals of Gerontology Series A: Biological Sciences and Medical Sciences · doi:10.1093/gerona/glt116 · Cited by 110
Self-citationThe Accuracy of Smart Devices for Measuring Physical Activity in Daily Life: Validation Study
(2018) · doi:10.2196/10972 · Cited by 93
Furlanetto, K. C., Bisca, G. W., Oldemberg, N., Sant'Anna, T. J., Morakami, F. K., Camillo, C. A., Cavalheri, V., Hernandes, N. A., Probst, V. S., Ramos, E. M., et al. (2010) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2009.10.024 · Cited by 87
Grant, P. M., Granat, M. H., Thow, M. K., & Maclaren, W. M. (2010) · Journal of Aging and Physical Activity · doi:10.1123/japa.18.2.171 · Cited by 60
Degroote, L., Hamerlinck, G., Poels, K., Maher, C., Crombez, G., De Bourdeaudhuij, I., Vandendriessche, A., Curtis, R. G., & DeSmet, A. (2020) · JMIR mhealth and uhealth · doi:10.2196/16674 · Cited by 60
“As this is a free-living study, the ActiGraph GT3X+ (ActiGraph) triaxial accelerometer was used as a reliable and valid reference for measuring step count [51-53] and MVPA [54,55].”
MethodYoung, M. D., Collins, C. E., Callister, R., Plotnikoff, R. C., Doran, C. M., & Morgan, P. J. (2014) · Contemporary Clinical Trials · doi:10.1016/j.cct.2013.11.004 · Cited by 19
“Physical activity and sedentary behaviour measures Step counts are objectively measured using Yamax SW200 pedometers (Yamax Corporation, Kumamoto City, Japan), which are both reliable [43] and valid [44] physical activity measures for adults.”
Method
Metadata
- Authors
- LE MASURIER, G. C., LEE, S. M., & TUDOR-LOCKE, C.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2004-05
- Volume
- 36
- Issue
- 5
- Pages
- 905-910
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2016962446
- Cited by
- 229
- References
- 13
- FWCI
- 7.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.