Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 342

The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.

Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure

FRUIN, MARGARET L., RANKIN, JANET WALBERG·2004·Medicine & Science in Sports & Exercise

Abstract

UNLABELLED: The SenseWear Armband (SWA; BodyMedia, Inc.), using multiple sensors, was designed to estimate energy expenditure (EE) in free-living individuals. PURPOSE: To examine the reliability and validity of the SWA during rest and exercise compared with indirect calorimetry (IC). METHODS: EE was assessed with SWA and IC in 13 males during two resting and one cycle ergometry (40 min at 60% VO2peak) sessions. In a second experiment, 20 adults walked on a treadmill for 30 min at three intensities (80.5 m x min, 0% grade; 107.3 m x min, 0% grade; 107.3 m x min, 5% grade) while IC and SWA measured EE. RESULTS: At rest, no significant differences were found between EE measurements from the SWA (1.3 +/- 0.1 kcal x min) and IC (1.3 +/- 0.1 kcal x min), and the two methods were highly correlated (r = 0.76; P < 0.004). The SWA EE estimation was reliable when comparing the two resting visits (r = 0.93; P < 0.001). For the ergometer protocol, no significant differences were found between the SWA and IC measurements of EE early, mid, or late in exercise or for the total bout, although the measurements were poorly correlated (r = 0.03-0.12). The SWA EE estimate of walking increased with treadmill speed but not with incline. The SWA significantly overestimated (13-27%) the EE of walking with no grade (P < 0.02) and significantly underestimated (22%) EE on the 5% grade (P < 0.002). The SWA estimation of EE correlated moderately with IC (r = 0.47-0.69). CONCLUSION: The SWA provided valid and reliable estimates of EE at rest and generated similar mean estimates of EE as IC on the ergometer; however, individual error was large. The SWA overestimated the EE of flat walking and underestimated inclined walking EE.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000128144.91337.38

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 19 references

Cited by

See all 342

Metadata

Authors
FRUIN, M. L., & RANKIN, J. W.
Venue
Medicine & Science in Sports & Exercise
Published
2004-06
Volume
36
Issue
6
Pages
1063-1069
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2016138493
Cited by
342
References
19
FWCI
3.80
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure. https://app.cochat.ai/papers/10.1249/01.mss.0000128144.91337.38
The paper
FRUIN, M. L., & RANKIN, J. W. (2004). Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000128144.91337.38

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.