Accuracy of SRM and Power Tap Power Monitoring Systems for Bicycling
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
PURPOSE: : Although manufacturers of bicycle power monitoring devices SRM and Power Tap (PT) claim accuracy to within 2.5%, there are limited scientific data available in support. The purpose of this investigation was to assess the accuracy of SRM and PT under different conditions. METHODS: : First, 19 SRM were calibrated, raced for 11 months, and retested using a dynamic CALRIG (50-1000 W at 100 rpm). Second, using the same procedure, five PT were repeat tested on alternate days. Third, the most accurate SRM and PT were tested for the influence of cadence (60, 80, 100, 120 rpm), temperature (8 and 21 degrees C) and time (1 h at ~300 W) on accuracy. Finally, the same SRM and PT were downloaded and compared after random cadence and gear surges using the CALRIG and on a training ride. RESULTS: : The mean error scores for SRM and PT factory calibration over a range of 50 - 1000 W were 2.3 +/- 4.9% and -2.5 +/- 0.5%, respectively. A second set of trials provided stable results for 15 calibrated SRM after 11 months (-0.8 +/- 1.7%), and follow-up testing of all PT units confirmed these findings (-2.7 +/- 0.1%). Accuracy for SRM and PT was not largely influenced by time and cadence; however, power output readings were noticeably influenced by temperature (5.2% for SRM and 8.4% for PT). During field trials, SRM average and max power were 4.8% and 7.3% lower, respectively, compared with PT. CONCLUSIONS: : When operated according to manufacturers instructions, both SRM and PT offer the coach, athlete, and sport scientist the ability to accurately monitor power output in the lab and the field. Calibration procedures matching performance tests (duration, power, cadence, and temperature) are, however, advised as the error associated with each unit may vary.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and analysis of research on sport performance enhancement
HOPKINS, W. G., HAWLEY, J. A., & BURKE, L. M. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199903000-00018 · Cited by 708
Cited by
Yeo, W. K., Paton, C. D., Garnham, A. P., Burke, L. M., Carey, A. L., & Hawley, J. A. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90882.2008 · Cited by 283
Ketone Diester Ingestion Impairs Time-Trial Performance in Professional Cyclists
Leckey, J. J., Ross, M. L., Quod, M., Hawley, J. A., & Burke, L. M. (2017) · Frontiers in Physiology · doi:10.3389/fphys.2017.00806 · Cited by 129
“The set-up of the bike was performed by team mechanics to replicate each rider’s unique bicycle position and was fitted with a calibrated (Gardner et al., 2004) SRM cycling power meter (scientific version, 8 strain gauge, Schoberer Rad Meβtechnik; Jülich, Germany), set to sample at 1-s intervals.”
MethodIncrease in Maximal Cycling Power With Acute Dietary Nitrate Supplementation
Rimer, E. G., Peterson, L. R., Coggan, A. R., & Martin, J. C. (2016) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2015-0533 · Cited by 81
A six-year monitoring case study of a top-10 cycling grand tour finisher.
Pinot, J., & Grappe, F. (2015) · Journal of Sports Sciences · doi:10.1080/02640414.2014.969296 · Cited by 72
Validity of the Stryd power meter in measuring running parameters at submaximal speeds
Imbach, F., Candau, R., Chailan, R., & Perrey, S. (2020) · Sports · doi:10.3390/sports8070103 · Cited by 72
Metadata
- Authors
- GARDNER, A. S., STEPHENS, S., MARTIN, D. T., LAWTON, E., LEE, H., & JENKINS, D.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2004-07
- Volume
- 36
- Issue
- 7
- Pages
- 1252-1258
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2079818967
- Cited by
- 183
- References
- 1
- FWCI
- 6.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Accuracy of SRM and Power Tap Power Monitoring Systems for Bicycling. https://app.cochat.ai/papers/10.1249/01.mss.0000132380.21785.03
- The paper
- GARDNER, A. S., STEPHENS, S., MARTIN, D. T., LAWTON, E., LEE, H., & JENKINS, D. (2004). Accuracy of SRM and Power Tap Power Monitoring Systems for Bicycling. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000132380.21785.03
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.