The DOI matches its Crossref record.
Muscle, Ligament, and Joint-Contact Forces at the Knee during Walking
Abstract
PURPOSE: In vivo measurement of the forces and strains in human tissues is currently impracticable. Computer modeling and simulation allows estimates of these quantities to be obtained noninvasively. This paper reviews our recent work on muscle, ligament, and joint loading at the knee during gait. METHODS: Muscle and ground-reaction forces obtained from a sophisticated computer simulation of walking were input into a detailed model of the lower limb to obtain ligament and joint-contact loading at the knee for one full cycle of gait. RESULTS: Peak anterior cruciate ligament (ACL) force occurred in early stance and was mainly determined by the anterior pull of the patellar tendon on the tibia. The medial collateral ligament was the primary restraint to anterior tibial translation (ATT) in the ACL-deficient knee. ATT in the ACL-deficient knee can be reduced to the level calculated for the intact knee by increasing hamstrings muscle force. Reducing quadriceps force was insufficient to restore ATT to the level calculated for the intact knee. For both normal and ACL-deficient walking, the resultant force acting between the femur and tibia remained mainly on the medial side of the knee. The knee adductor moment was resisted by a combination of muscle and ligament forces. CONCLUSION: Knee-ligament loading during the stance phase of gait is explained by the pattern of anterior shear force applied to the leg. The distribution of force at the tibiofemoral joint is determined by the variation in the external adductor moment applied at the knee. The forces acting at the tibiofemoral and patellofemoral joints are similar during normal and ACL-deficient gait. Hamstrings facilitation is more effective than quadriceps avoidance in reducing ATT during ACL-deficient gait.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Standardized Loads Acting in Knee Implants
Bergmann, G., Bender, A., Graichen, F., Dymke, J., Rohlmann, A., Trepczynski, A., Heller, M. O., & Kutzner, I. (2014) · PLoS ONE · doi:10.1371/journal.pone.0086035 · Cited by 382
Martin, R. L., Davenport, T. E., Paulseth, S., Wukich, D. K., & Godges, J. J. (2013) · Journal of Orthopaedic & Sports Physical Therapy · doi:10.2519/jospt.2013.0305 · Cited by 269
Patellofemoral Mechanics: a Review of Pathomechanics and Research Approaches
Wheatley, M. G. A., Rainbow, M. J., & Clouthier, A. L. (2020) · Current Reviews in Musculoskeletal Medicine · doi:10.1007/s12178-020-09626-y · Cited by 68
Moment arm of the knee-extensor mechanism measured in vivo across a range of daily activities
Gray, H. A., Guan, S., Thomeer, L. T., & Pandy, M. G. (2021) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2021.110484 · Cited by 10
Self-citation
Metadata
- Authors
- Shelburne, K. B., Torry, M. R., & Pandy, M. G.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-11
- Volume
- 37
- Issue
- 11
- Pages
- 1948-1956
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2098013710
- Cited by
- 281
- References
- 0
- FWCI
- 5.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Muscle, Ligament, and Joint-Contact Forces at the Knee during Walking. https://app.cochat.ai/papers/10.1249/01.mss.0000180404.86078.ff
- The paper
- Shelburne, K. B., Torry, M. R., & Pandy, M. G. (2005). Muscle, Ligament, and Joint-Contact Forces at the Knee during Walking. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000180404.86078.ff
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.