The Validity and Reliability of Intestinal Temperature during Intermittent Running
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
PURPOSE: In many sporting and occupational settings, measuring core temperature using invasive methods is not practical. In these circumstances, ingestible temperature sensor capsules are a promising alternative. To date, no researcher has investigated the validity of intestinal temperature (T(int)) during free running or examined the between-trial reproducibility of this technique. Therefore, in two investigations, we examined the validity and reliability of Tint during prolonged intermittent shuttle running. METHODS: In investigation A, 10 male games players completed 60 min of exercise while their rectal temperature (T(rec)) and T(int) were monitored. In investigation B, Tint was measured while nine males undertook two 90-min bouts of exercise, separated by 7 d. RESULTS: A mean systematic bias of -0.15 degrees C (95% CI, 0.10-0.20) was found between T(int) and T(rec) during exercise. This bias for T(int) to record higher temperatures than T(rec) was uniform through the range of measurements, such that the exercise-mediated changes in body temperature were similar between methods of measurement. The 95% limits of agreement were found to be +/- 0.22 degrees C (95% CI, 0.11-0.33) and correlations were high (r > 0.85), suggesting that random error between methods was acceptably small. In investigation B, the mean change between repeated trials was a negligible 0.01 degrees C (95% CI, -0.02 to 0.05). The within-subjects SD was 0.08 degrees C (95% CI, 0.05-0.15). Random error was uniform through the measurement range and was deemed acceptable on the basis of statistical power calculations. CONCLUSION: These findings suggest that the test-retest variability of Tint is acceptably small during intermittent shuttle running. The small amount of random measurement error and similar thermal responses to exercise suggest that Tint is as appropriate for use in exercise physiology research as T(rec), provided that the consistent bias between these measurement methods is allowed for.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1177/096228029900800204 · Cited by 9,619
Measuring agreement in method comparison studies
Bland, J. M., & Altman, D. G. (1999) · Statistical Methods in Medical Research · doi:10.1191/096228099673819272 · Cited by 9,619
Nicholas, C. W., Nuttall, F. E., & Williams, C. (2000) · Journal of Sports Sciences · doi:10.1080/026404100365162 · Cited by 327
Self-citation
Cited by
Périard, J. D., Eijsvogels, T. M. H., & Daanen, H. A. M. (2021) · Physiological Reviews · doi:10.1152/physrev.00038.2020 · Cited by 647
Byrne, C., & Lim, C. L. (2007) · British Journal of Sports Medicine · doi:10.1136/bjsm.2006.026344 · Cited by 456
Considerations for the measurement of core, skin and mean body temperatures
Taylor, N. A. S., Tipton, M. J., & Kenny, G. P. (2014) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2014.10.006 · Cited by 420
Reliability and validity of the CORE sensor to assess core body temperature during cycling exercise
Verdel, N., Podlogar, T., Ciuha, U., Holmberg, H.-C., Debevec, T., & Supej, M. (2021) · Sensors · doi:10.3390/s21175932 · Cited by 89
Metadata
- Authors
- GANT, N., ATKINSON, G., & WILLIAMS, C.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2006-11
- Volume
- 38
- Issue
- 11
- Pages
- 1926-1931
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2042606686
- Cited by
- 132
- References
- 4
- FWCI
- 3.33
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Validity and Reliability of Intestinal Temperature during Intermittent Running. https://app.cochat.ai/papers/10.1249/01.mss.0000233800.69776.ef
- The paper
- GANT, N., ATKINSON, G., & WILLIAMS, C. (2006). The Validity and Reliability of Intestinal Temperature during Intermittent Running. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/01.mss.0000233800.69776.ef
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.