CoChat

Estimation of Oxygen Uptake during Fast Running Using Accelerometry and Heart Rate

FUDGE, BARRY W., WILSON, JOHN, EASTON, CHRIS, IRWIN, LAURA, CLARK, JONATHAN, HADDOW, OLIVIA, KAYSER, BENGT, PITSILADIS, YANNIS P. · 2007 · Medicine & Science in Sports & Exercise
Cited by 103

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

UNLABELLED: Previous investigations have reported that accelerometer counts plateau during running at increasingly faster speeds. PURPOSE: To assess whether biomechanical and/or device limitations cause this phenomenon and the feasibility of generating oxygen uptake (.VO2) prediction equations from the combined use of accelerometry and heart rate during walking and running. METHODS: : Sixteen endurance-trained subjects completed two exercise tests on a treadmill. The first was a continuous incremental test to volitional exhaustion to determine ventilatory threshold and peak .VO2. The second was a discontinuous incremental exercise test while walking (3, 5, and 7 km.h(-1)) and running (8, 10, 12, 14, 16, 18, and 20 km.h(-1), or until volitional exhaustion). Subjects completed 3 min of exercise at each speed, followed by 3-5 min of recovery. Activity counts from uni- and triaxial accelerometers, heart rate, and gas exchange were measured throughout exercise. RESULTS: All accelerometer outputs rose linearly with speed during walking. During running, uniaxial accelerometer outputs plateaued, whereas triaxial output rose linearly with speed up to and including 20 km.h(-1). Prediction of .VO2 during walking and running using heart rate (R2 = 0.42 and 0.59, respectively), accelerometer counts (R2 = 0.48-0.83 and 0.76, respectively), the combined methodologies (R2 = 0.54-0.85 and 0.80, respectively), and the combined methodologies calibrated with individual data (R2 = 0.99-1.00 and 0.99, respectively) was completed by linear regression. CONCLUSIONS: Uni- and triaxial accelerometer outputs have a linear relationship with speed during walking. During running, uniaxial accelerometer outputs plateau because of the biomechanics of running, whereas triaxial accelerometer output has a linear relationship. The combined methodologies predict .VO2 better than either predictor alone; a subject's individually calibrated data further improves .VO2 estimation.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/01.mss.0000235884.71487.21

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 103

Metadata

Authors
FUDGE, B. W., WILSON, J., EASTON, C., IRWIN, L., CLARK, J., HADDOW, O., KAYSER, B., & PITSILADIS, Y. P.
Venue
Medicine & Science in Sports & Exercise
Published
2007-01
Volume
39
Issue
1
Pages
192-198
ISSN
0195-9131 (ISSN-L)
OpenAlex
W1967471679
Cited by
103
References
8
FWCI
10.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.