Estimation of Oxygen Uptake during Fast Running Using Accelerometry and Heart Rate
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
UNLABELLED: Previous investigations have reported that accelerometer counts plateau during running at increasingly faster speeds. PURPOSE: To assess whether biomechanical and/or device limitations cause this phenomenon and the feasibility of generating oxygen uptake (.VO2) prediction equations from the combined use of accelerometry and heart rate during walking and running. METHODS: : Sixteen endurance-trained subjects completed two exercise tests on a treadmill. The first was a continuous incremental test to volitional exhaustion to determine ventilatory threshold and peak .VO2. The second was a discontinuous incremental exercise test while walking (3, 5, and 7 km.h(-1)) and running (8, 10, 12, 14, 16, 18, and 20 km.h(-1), or until volitional exhaustion). Subjects completed 3 min of exercise at each speed, followed by 3-5 min of recovery. Activity counts from uni- and triaxial accelerometers, heart rate, and gas exchange were measured throughout exercise. RESULTS: All accelerometer outputs rose linearly with speed during walking. During running, uniaxial accelerometer outputs plateaued, whereas triaxial output rose linearly with speed up to and including 20 km.h(-1). Prediction of .VO2 during walking and running using heart rate (R2 = 0.42 and 0.59, respectively), accelerometer counts (R2 = 0.48-0.83 and 0.76, respectively), the combined methodologies (R2 = 0.54-0.85 and 0.80, respectively), and the combined methodologies calibrated with individual data (R2 = 0.99-1.00 and 0.99, respectively) was completed by linear regression. CONCLUSIONS: Uni- and triaxial accelerometer outputs have a linear relationship with speed during walking. During running, uniaxial accelerometer outputs plateau because of the biomechanics of running, whereas triaxial accelerometer output has a linear relationship. The combined methodologies predict .VO2 better than either predictor alone; a subject's individually calibrated data further improves .VO2 estimation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Energetics of running: a new perspective
Kram, R., & Taylor, C. R. (1990) · Nature · doi:10.1038/346265a0 · Cited by 821 · cited 1×
“With this in mind, and the concept that vertical (13,16) and horizontal (9) forces are major determinants of metabolic cost during running, a further application of accelerometry may be a discriminatory role for differences between individuals in running economy or changes in running economy within individuals.”
BackgroundEston, R. G., Rowlands, A. V., & Ingledew, D. K. (1998) · Journal of Applied Physiology · doi:10.1152/jappl.1998.84.1.362 · Cited by 643 · cited 1×
“A number of studies have reported improved accuracy to predict physical activity and energy expenditure when combining accelerometry and heart rate compared with their respective individual methods (1,10,11,19,20).”
ResultBrage, S., Brage, N., Franks, P. W., Ekelund, U., Wong, M.-Y., Andersen, L. B., Froberg, K., & Wareham, N. J. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00703.2003 · Cited by 473 · cited 3×
“, Fort Walton beach, FL) sensitive to body accelerations in the vertical direction (6,7,21,27,28); 2) a”
BackgroundMethodSimultaneous heart rate-motion sensor technique to estimate energy expenditure
STRATH, S. J., BASSETT, D. R., SWARTZ, A. M., & THOMPSON, D. L. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200112000-00022 · Cited by 134 · cited 3×
“, Fort Walton beach, FL) sensitive to body accelerations in the vertical direction (6,7,21,27,28); 2) a”
BackgroundMethodIntegration of physiological and accelerometer data to improve physical activity assessment
STRATH, S. J., BRAGE, S., & EKELUND, U. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000185650.68232.3f · Cited by 126 · cited 3×
“Combining methodologies seems promising, but it remains to be determined whether laboratory-defined relationships between heart rate, accelerometer counts, and oxygen uptake (V̇O2) will also apply in free-living situations (29).”
BackgroundA combined heart rate and movement sensor: proof of concept and preliminary testing study
Rennie, K., Rowsell, T., Jebb, S., Holburn, D., & Wareham, N. (2000) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600973 · Cited by 83 · cited 1×
“Subsequent studies have explored various calibration methods using the combined methodologies (6,7,25,27,28,32).”
MethodAccelerometry and Heart Rate as a Measure of Physical Fitness: Proof of Concept
PLASQUI, G., & WESTERTERP, K. R. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000161805.61893.c0 · Cited by 56
Cited by
Dowd, K. P., Szeklicki, R., Minetto, M. A., Murphy, M. H., Polito, A., Ghigo, E., van der Ploeg, H., Ekelund, U., Maciaszek, J., Stemplewski, R., et al. (2018) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-017-0636-2 · Cited by 385
Accelerometers and pedometers: methodology and clinical application
Corder, K., Brage, S., & Ekelund, U. (2007) · Current Opinion in Clinical Nutrition and Metabolic Care · doi:10.1097/mco.0b013e328285d883 · Cited by 339
Vähä-Ypyä, H., Vasankari, T., Husu, P., Mänttäri, A., Vuorimaa, T., Suni, J., & Sievänen, H. (2015) · PLOS ONE · doi:10.1371/journal.pone.0134813 · Cited by 277
Validity of activity monitors in health and chronic disease: a systematic review
Van Remoortel, H., Giavedoni, S., Raste, Y., Burtin, C., Louvaris, Z., Gimeno-Santos, E., Langer, D., Glendenning, A., Hopkinson, N. S., Vogiatzis, I., et al. (2012) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/1479-5868-9-84 · Cited by 277
Barrett, S., Midgley, A., & Lovell, R. (2014) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2013-0418 · Cited by 236
Validation of the GT3X ActiGraph in children and comparison with the GT1M ActiGraph
Hänggi, J. M., Phillips, L. R. S., & Rowlands, A. V. (2013) · Journal of Science and Medicine in Sport · doi:10.1016/j.jsams.2012.05.012 · Cited by 196
Comparing the performance of three generations of ActiGraph accelerometers
Rothney, M. P., Apker, G. A., Song, Y., & Chen, K. Y. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.90641.2008 · Cited by 177
Screening for low energy availability in male athletes: attempted validation of LEAM-Q
Lundy, B., Torstveit, M. K., Stenqvist, T. B., Burke, L. M., Garthe, I., Slater, G. J., Ritz, C., & Melin, A. K. (2022) · Nutrients · doi:10.3390/nu14091873 · Cited by 70
Beis, L. Y., Polyviou, T., Malkova, D., & Pitsiladis, Y. P. (2011) · Journal of the International Society of Sports Nutrition · doi:10.1186/1550-2783-8-24 · Cited by 36
Self-citation
Metadata
- Authors
- FUDGE, B. W., WILSON, J., EASTON, C., IRWIN, L., CLARK, J., HADDOW, O., KAYSER, B., & PITSILADIS, Y. P.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2007-01
- Volume
- 39
- Issue
- 1
- Pages
- 192-198
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1967471679
- Cited by
- 103
- References
- 8
- FWCI
- 10.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.