Accelerometry and Heart Rate as a Measure of Physical Fitness: Proof of Concept
Open accessAbstract
PURPOSE: This study focused on developing a new method to assess VO2max outside laboratory conditions and without the need for maximal exertion. We hypothesized that the combined use of accelerometry and HR monitoring, under daily life conditions, could provide a good estimate of physical fitness. METHODS: Twenty-six healthy subjects (15 women, 11 men), aged 28 +/- 7 yr, performed a maximal incremental test on a bicycle ergometer to determine VO2max. Body composition was measured with underwater weighing and deuterium dilution using a three-compartment model. A triaxial accelerometer (Tracmor) and an HR monitor were worn for seven consecutive days under free-living conditions. The ratio of HR to activity counts per minute (ACM) was used as a fitness index (HR.ACM(-1)). RESULTS: As hypothesized, HR.ACM(-1) was significantly correlated with VO2max. Using fat-free mass (FFM) (P < 0.0001), age (P = 0.025), and HR.ACM(-1) (P = 0.021) as the independent variables, the explained variation in VO2max was 76% (P < 0.0001, SEE = 363 mL x min(-1)). In order to generate a prediction formula that is applicable in the field when no data on body composition are available, the same analysis was done with body mass and gender in the model instead of FFM. HR.ACM(-1) was significantly (P = 0.023) correlated with VO2max. The total explained variation of the model was 71%, with a SEE of 409 mL x min(-1), or 13.7% of the average VO2max. CONCLUSION: After correction for body composition, VO2max was significantly related to HR.ACM(-1). It is, to our knowledge, the first tool that yields a measure of VO2max by monitoring people in their daily life activities without the need for a specific protocol or for maximal exertion, and therefore is applicable to a large variety of subjects.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Wearable devices, such as activity trackers and smartwatches, increasingly provide opportunities for non-intrusive objective monitoring of biological signals such as HR and movement during free-living, potentially enabling more precise prediction of VO2max without the need to conduct a specific exercise test.
“Wearable devices, such as activity trackers and smartwatches, increasingly provide opportunities for non-intrusive objective monitoring of biological signals such as HR and movement during free-living, potentially enabling more precise prediction of VO2max without the need to conduct a specific exercise test [140].”
From Human-centred artificial intelligence for mobile health sensing: challenges and opportunities (2023) · cites this paper as [140]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Åstrand, P. O., & Ryhming, I. (1954) · Journal of Applied Physiology · doi:10.1152/jappl.1954.7.2.218 · Cited by 1,558 · see citing works
A maximal multistage 20-m shuttle run test to predict $$\dot V$$ O2 max
L�ger, L. A., & Lambert, J. Y. (1982) · European Journal of Applied Physiology · doi:10.1007/bf00428958 · Cited by 1,231 · see citing works
A Means of Assessing Maximal Oxygen Intake
Cooper, K. H. (1968) · JAMA · doi:10.1001/jama.203.3.201 · Cited by 1,105 · see citing works
The Effect of Endurance Training on Parameters of Aerobic Fitness
Jones, A. M., & Carter, H. (2000) · Sports Medicine · doi:10.2165/00007256-200029060-00001 · Cited by 935 · see citing works
Variability of Aerobic Performance in the Laboratory and Its Physiologic Correlates
Kuipers, H., VERSTAPPEN, F. T. J., KEIZER, H. A., Geurten, P., & van Kranenburg, G. (1985) · International Journal of Sports Medicine · doi:10.1055/s-2008-1025839 · Cited by 884 · see citing works
Physical fitness and activity as separate heart disease risk factors: a meta-analysis
WILLIAMS, P. T. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200105000-00012 · Cited by 724 · see citing works
Estimation of &OV0312;O2max from a one-mile track walk, gender, age, and body weight
KLINE, G. M., Porcari, J. P., Hintermeister, R. A., Freedson, P. S., Ward, A., McCarron, R., Ross, J., & Rippe, J. M. (1987) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-198706000-00012 · Cited by 521 · see citing works
Westerterp, K. R., Wouters, L., & Lichtenbelt, W. D. V. M. (1995) · Obesity Research · doi:10.1002/j.1550-8528.1995.tb00007.x · Cited by 328 · see citing works
Self-citationPhysical activity assessment with accelerometers
Westerterp, K. R. (1999) · International Journal of Obesity · doi:10.1038/sj.ijo.0800883 · Cited by 290 · see citing works
Self-citationIndirect determination of maximal O2 consumption in man
Margaria, R., Aghemo, P., & Rovelli, E. (1965) · Journal of Applied Physiology · doi:10.1152/jappl.1965.20.5.1070 · Cited by 153 · see citing works
VO2max estimation from a submaximal 1-mile track jog for fit college-age individuals
George, J. D., Vehrs, P. R., ALLSEN, P. E., et al. (1993) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199303000-00017 · Cited by 111 · see citing works
Validation of the Tracmor triaxial accelerometer system for walking
Levine, J. A., Baukol, P., & Westerterp, K. R. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200109000-00024 · Cited by 102 · see citing works
Self-citationA multi-stage shuttle run as a predictor of running performance and maximal oxygen uptake in adults.
Paliczka, V. J., Nichols, A., & Boreham, C. A. (1987) · British Journal of Sports Medicine · doi:10.1136/bjsm.21.4.163 · Cited by 97 · see citing works
Use of a triaxial accelerometer to validate reported food intakes
Goris, A. H. C., Meijer, E. P., Kester, A. D. M., & Westerterp, K. R. (2001) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/73.3.549 · Cited by 72 · see citing works
Self-citationEXERCISE MANAGEMENT OF OBESITY
Leermakers, E. A., Dunn, A. L., & Blair, S. N. (2000) · Medical Clinics of North America · doi:10.1016/s0025-7125(05)70229-7 · Cited by 65 · see citing works
Weyand, P. G., Kelly, M., Blackadar, T., Darley, J. C., Oliver, S. R., Ohlenbusch, N. E., Joffe, S. W., & Hoyt, R. W. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.91.1.451 · Cited by 61 · see citing works
Westerterp, K. R., & Bouten, C. V. C. (1997) · Zeitschrift für Ernährungswissenschaft · doi:10.1007/bf01617795 · Cited by 50 · see citing works
Self-citation
Flagged first, then by citations
Cited by
Sorted by citations
Bize, R., Johnson, J. A., & Plotnikoff, R. C. (2007) · Preventive Medicine · doi:10.1016/j.ypmed.2007.07.017 · Cited by 1,149 · see citing works
Assessing Physical Activity Using Wearable Monitors: Measures of Physical Activity
BUTTE, N. F., EKELUND, U., & WESTERTERP, K. R. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399c0e · Cited by 359 · see citing works
Self-citationPredicting V˙O2max with an Objectively Measured Physical Activity in Japanese Women
CAO, Z.-B., MIYATAKE, N., HIGUCHI, M., MIYACHI, M., ISHIKAWA-TAKATA, K., & TABATA, I. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181af238d · Cited by 76 · see citing works
Cardiorespiratory fitness estimation in free-living using wearable sensors
Altini, M., Casale, P., Penders, J., & Amft, O. (2016) · Artificial Intelligence in Medicine · doi:10.1016/j.artmed.2016.02.002 · Cited by 34 · see citing works
Human-centred artificial intelligence for mobile health sensing: challenges and opportunities
Dang, T., Spathis, D., Ghosh, A., & Mascolo, C. (2023) · Royal Society Open Science · doi:10.1098/rsos.230806 · Cited by 30 · see citing works
- Authors
- PLASQUI, G., & WESTERTERP, K. R.
- Affiliations
- Maastricht University (NL)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2005-05
- Volume
- 37
- Issue
- 5
- Pages
- 872-876
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2016065466
- Cited by
- 56
- References
- 17
- Citations by year
- 2025: 1 · 2024: 1 · 2023: 5 · 2020: 2 · 2019: 2 · 2018: 2 · 2017: 5 · 2016: 2 · 2015: 2 · 2014: 5 · 2013: 5 · 2012: 3
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- Licence
- other-oa
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Research Publications (Maastricht University) (publishedVersion, other-oa)
- Research Publications (Maastricht University) (submittedVersion, other-oa)
- Topics
- Health Sciences › Medicine › Complementary and alternative medicine › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Physiology › Physical Activity and Health
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Keywords
- VO2max prediction, physical fitness assessment, accelerometry, heart rate monitoring, triaxial accelerometer, free-living conditions, physical fitness index, body composition, fat-free mass, prediction formula, wearable sensors
- MeSH terms
- Activities of Daily Living, Adolescent, Adult, Age Factors, Body Composition, Exercise Test, Female, Heart Rate, Humans, Male, Middle Aged, Oxygen Consumption, Physical Fitness, Regression Analysis, Monitoring, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review