The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Effect of WBGT Index Measurement Location on Heat Stress Category Classification
Abstract
UNLABELLED: The location of the wet bulb globe temperature (WBGT) index measurement may affect heat stress flag category classification. PURPOSE: This study aimed to compare WBGT measurements at three locations along the Boston Marathon race course and compare WBGT estimates for meteorological stations and 72-h advanced WBGT forecasts. METHODS: WBGT was measured hourly from 1000 to 1400 h at approximately 7 km, approximately 18 km, and approximately 30 km on the Boston Marathon race course. Simultaneous WBGT estimates were made for two meteorological stations southeast of the course via a commercial online system, which also provided 72-h advanced forecasts. RESULTS: The measurement difference (mean ± SD) among course locations was 0.2°C ± 1.8°C WBGT (ANOVA, P > 0.05). The difference between course and stations was 1.9°C ± 2.4°C WBGT (t-test, P < 0.05). Station values underestimated (n = 98) or overestimated (n = 13) course values by >3°C WBGT (>0.5 flag category) in 111 of 245 paired comparisons (45%). Higher black globe and lower wet bulb temperatures explained over- and underestimates, respectively. Significant underestimates of WBGT resulted in misclassification of green (labeled white) and black (labeled red) course flag categories (χ2, P < 0.05). Forecast data significantly underestimated red (labeled amber) and black (labeled red) course flag categories. CONCLUSIONS: Differences in WBGT index along 23 km of the Boston Marathon race route can be small enough to warrant single measurements. However, significant misclassification of flag categories occurred using WBGT estimates for meteorological stations; thus, local measurements are preferred. If the relation between station WBGT forecasts and the race sites can be established, the forecast WBGT values could be corrected to give advanced warning of approximate flag conditions. Similar work is proposed for other venues to improve heat stress monitoring.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The two WBGT instruments (QUESTemp44 and Kestrel5400) were validated to measure WBGT and used in heat stress exposure research.
“These instruments were validated to measure WBGT and used in heat stress exposure research (Bernard and Barrow, 2013; Cheuvront et al., 2015).”
From Assessment of Heat Stress Exposure among Construction Workers in the Hot Desert Climate of Saudi Arabia (2019) · cites this paper as Cheuvront et al., 2015
Citations
Cites
Modeling the Wet Bulb Globe Temperature Using Standard Meteorological Measurements
Liljegren, J. C., Carhart, R. A., Lawday, P., Tschopp, S., & Sharp, R. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802310770 · Cited by 404
Prediction of Workplace Wet Bulb Global Temperature
Bernard, T. E. (1999) · Applied Occupational and Environmental Hygiene · doi:10.1080/104732299303296 · Cited by 128
Flagged first, then by citations
Research works printed but not linked: 18
- 1987, Position Stand: the prevention of thermal injuries during distance running., Med Sci Sport Exerc, 19, 529
- Bernard, 2013, Empirical approach to outdoor WBGT from meteorological data and performance of two different instrument designs., Ind Health, 51, 79, 10.2486/indhealth.2012-0160 · DOI · Paper page
- Buskirk, 1971, Microclimate over artificial turf., Natl Assoc Coll Direct Athl Q, 5, 22
- Cohen, 1992, A power primer., Psychol Bull, 112, 155, 10.1037/0033-2909.112.1.155 · DOI · Paper page
- Copas, 1983, Regression, prediction and shrinkage., J R Statist Soc B, 45, 311, 10.1111/j.2517-6161.1983.tb01258.x · DOI · Paper page
- DAmbrosia Alfano, 2012, On the problems related to natural wet bulb temperature indirect evaluation for the assessment of hot thermal environments by means of WBGT., Ann Occup Hyg, 9, 1063
- Davey, 2005, Microclimate exposures of surface-based weather stations., Bull Am Meteorol Soc, 86, 497, 10.1175/BAMS-86-4-504 · DOI
- Ely, 2007, Impact of weather on marathon-running performance., Med Sci Sport Exerc, 39, 487, 10.1249/mss.0b013e31802d3aba · DOI
- Harlan, 2006, Neighborhood microclimates and vulnerability to heat stress., Soc Sci Med, 63, 2847, 10.1016/j.socscimed.2006.07.030 · DOI · Paper page
- Hughson, 1983, Monitoring road racing in the heat., Physician Sport Med, 11, 94, 10.1080/00913847.1986.11708538 · DOI
- Markowski, 2009, A systematic method for teaching post hoc analysis of chi-square tests., Decis Sci J Innov Educ, 7, 59, 10.1111/j.1540-4609.2008.00202.x · DOI
- McCann, 1997, Wet bulb globe temperature index and performance in competitive distance runners., Med Sci Sport Exerc, 29, 955, 10.1097/00005768-199707000-00016 · DOI
- Mielke, 1996, Artificial skill and validation in meteorological forecasting., Weather Forecast, 11, 169, 10.1175/1520-0434(1996)011<0153:ASAVIM>2.0.CO;2 · DOI
- Patel, 2013, Comparison of methods for estimating wet-bulb globe temperature index from standard meteorological measurements., Mil Med, 178, 926, 10.7205/MILMED-D-13-00117 · DOI
- Roberts, 2010, Determining a do not start temperature for a marathon on the basis of adverse outcomes., Med Sci Sports Exerc, 42, 226, 10.1249/MSS.0b013e3181b1cdcf · DOI
- Santee, 1994, Effects of meteorological parameters on adequate evaluation of the thermal environment., J Therm Biol, 19, 187, 10.1016/0306-4565(94)90030-2 · DOI
- Sauter, 2013, A Wet-Bulb Globe Temperature validation study using standard meteorological inputs and modeled solar irradiance., J Oper Meteor, 1, 215, 10.15191/nwajom.2013.0118 · DOI
- Yaglou, 1957, Control of heat casualties at military training centers., AMA Arch Ind Health, 16, 302
Cited by
Sorted by citations
Al-Bouwarthan, M., Quinn, M. M., Kriebel, D., & Wegman, D. H. (2019) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxz033 · Cited by 158
Practical Hydration Solutions for Sports
Belval, L. N., Hosokawa, Y., Casa, D. J., Adams, W. M., Armstrong, L. E., Baker, L. B., Burke, L., Cheuvront, S., Chiampas, G., González-Alonso, J., et al. (2019) · Nutrients · doi:10.3390/nu11071550 · Cited by 132
Self-citation
Metadata
- Authors
- CHEUVRONT, S. N., CARUSO, E. M., HEAVENS, K. R., KARIS, A. J., SANTEE, W. R., TROYANOS, C., & D’HEMECOURT, P.
- Affiliations
- U.S. Army Research Institute of Environmental Medicine (US)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2015-09
- Volume
- 47
- Issue
- 9
- Pages
- 1958-1964
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2330447295
- Cited by
- 34
- References
- 2
- Citations by year
- 2026: 2 · 2025: 6 · 2024: 1 · 2023: 5 · 2021: 4 · 2020: 4 · 2019: 6 · 2018: 3 · 2017: 1 · 2015: 1
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Thermoregulation and physiological responses
- Physical Sciences › Environmental Science › Environmental Engineering › Urban Heat Island Mitigation
- Life Sciences › Agricultural and Biological Sciences › Animal Science and Zoology › Effects of Environmental Stressors on Livestock
- Keywords
- wet bulb globe temperature, heat stress, Boston Marathon, black globe temperature, wet-bulb temperature, heat stress monitoring, racecourses
- MeSH terms
- Boston, Environmental Monitoring, Hot Temperature, Humans, Weather, Heat Stress Disorders
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review