The Respiratory Compensation Point and the Deoxygenation Break Point Are Not Valid Surrogates for Critical Power and Maximum Lactate Steady State
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The physiological threshold separating “sustainable” and “nonsustainable” exercise intensities has undoubtedly, in practical terms, dictated human activity since the origin of man. A preponderance of evidence, from nearly a century of research, has repeatedly identified the critical power (CP)/maximum lactate steady-state (MLSS) parameters as a robust quantification of this physiological threshold. The CP/MLSS defines the highest exercise intensity for which the energetic requirements can be met primarily by oxidative metabolism. As such, CP/MLSS represents the highest exercise intensity for which a steady-state for many crucial variables can be achieved within the exercising skeletal muscle (e.g., pH, inorganic phosphate, and phosphocreatine), the peripheral circulation (e.g., blood lactate, blood pH, skeletal muscle blood flow), and the systemic organism (e.g., oxygen consumption and neuromuscular fatigue development). Thus, the physiological underpinnings of CP/MLSS are of the upmost importance for understanding the mechanistic bases of exercise tolerance in both health and disease. With increasing regularity, it has been argued that the respiratory compensation point (RCP)/deoxyhemoglobin-myoglobin break point (deoxy-BP) parameters are surrogates for critical power (CP)/maximum lactate steady-state (MLSS). This contention primarily relies on the premise that the work and metabolic rates associated with these parameters are, on average, not statistically different. This “absence of evidence” of a difference has been argued to be “evidence of absence” to support equivalence between the RCP/deoxy-BP and CP/MLSS (1,2). However, in addition to somewhat questionable logic, this argument largely disregards the disparate physiological mechanisms, sequential expression, and inconsistent relationship among these parameters. Moreover, this thesis is inconsistent when these parameters are evaluated across the organism and across diverse species. It has also been argued that the selection of assessing RCP/deoxy-BP or CP/MLSS can be determined by the availability of measurement instruments. However, we are firm believers in the concept that one should let one’s intentions determine the method and not vice versa, such that the physiological relevance of the parameter should dictate the means of assessment. Regardless, substantiation of this argument of equivalence, if incorrect, would greatly impede the advancement of our understanding of the mechanistic bases for exercise tolerance in health and disease. It is our contention, that, in fact, there is substantial “evidence of absence” of RCP/deoxy-BP being physiological equivalents to CP/MLSS and, thus, here we argue, based on current evidence and a mechanistic physiological framework, that the RCP/deoxy-BP are not valid surrogates for CP/MLSS. PHYSIOLOGICAL DETERMINANTS OF RCP/DEOXY-BP The physiological bases of RCP/deoxy-BP must be considered when evaluating these parameters as potential surrogates for CP/MLSS. The RCP defines an exercise intensity at which frank hyperventilation ensues (i.e., increased V˙E/V˙CO2, decreased PaCO2 and PETCO2), for which a multitude of culprits have been identified. Indeed, body temperature and other factors (e.g., catecholamines, blood osmolarity) can directly influence ventilation and have been demonstrated to increase ventilation in a time-dependent fashion at exercise intensities below CP/MLSS (3). The primary stimulus for the RCP has been traditionally attributed to the progressively worsening metabolic acidosis during incremental exercise. For hyperventilation to occur with this stimulus, there must be an accumulation of hydrogen ions in the blood sufficient enough to overwhelm the buffering capacity and be detectable by the receptors modulating ventilation. As muscle pH, blood pH, and blood lactate all attain steady-state for exercise intensities up to CP/MLSS, the RCP, by definition, must occur at an exercise intensity above CP/MLSS. Thus, the numerous stimuli that can influence RCP clearly dissociate this parameter from CP/MLSS. The deoxy-BP is a relatively newly defined parameter that designates an exercise intensity at which the near-infrared spectroscopy-derived deoxygenated hemoglobin/myoglobin concentration begins to level-off during ramp incremental exercise. In terms of the equivalence between the deoxy-BP and CP/MLSS, there are several potential issues to consider. First, the majority of near-infrared spectroscopy measurements are constrained to the superficial regions of the interrogated muscle. As the deoxy-BP has been most often observed in the quadriceps muscles, this means that more glycolytic muscle fibers are the primary muscle fibers being assessed, whereas the deeper more oxidative muscle fibers are neglected. Using a specially designed near-infrared spectrometer, Okushima et al. (4) assessed the oxygenation characteristics of the superficial and deep muscles of the quadriceps during cycling exercise. Interest
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Exercise Intensity Thresholds: Identifying the Boundaries of Sustainable Performance
KEIR, D. A., FONTANA, F. Y., ROBERTSON, T. C., MURIAS, J. M., PATERSON, D. H., KOWALCHUK, J. M., & POGLIAGHI, S. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000613 · Cited by 205
KEIR, D. A., POGLIAGHI, S., & MURIAS, J. M. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001698 · Cited by 65
Exercise Thresholds on Trial: Are They Really Equivalent?
CAEN, K., VERMEIRE, K., BOURGOIS, J. G., & BOONE, J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001547 · Cited by 42
Cited by
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
The anaerobic threshold: 50+ years of controversy
Poole, D. C., Rossiter, H. B., Brooks, G. A., & Gladden, L. B. (2021) · The Journal of Physiology · doi:10.1113/jp279963 · Cited by 312
“Whether these terms actually represent a common metabolic rate has been the topic of much debate and polemic (see Broxterman et al. (2018) versusKeir et al. (2018)).”
BackgroundIdentification of Non-Invasive Exercise Thresholds: Methods, Strategies, and an Online App
Keir, D. A., Iannetta, D., Mattioni Maturana, F., Kowalchuk, J. M., & Murias, J. M. (2022) · Sports Medicine · doi:10.1007/s40279-021-01581-z · Cited by 193
Caen, K., Bourgois, J. G., Stassijns, E., & Boone, J. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04942-2 · Cited by 41
“2016), the available research gives opposing viewpoints on their mutual agreement, as well as an on the presumption that each of these thresholds represents the actual MMSS intensity (Craig et al. 2015; Keir et al. 2015a, 2018b, 2019; Broxterman et al. 2018; Marwood et al. 2019).”
BackgroundInglis, E. C., Iannetta, D., Keir, D. A., & Murias, J. M. (2020) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2019-0046 · Cited by 21
Metadata
- Authors
- BROXTERMAN, R. M., CRAIG, J. C., & RICHARDSON, R. S.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2018-11
- Volume
- 50
- Issue
- 11
- Pages
- 2379-2382
- ISSN
- 0195-9131 (ISSN-L)
- 1530-0315
- OpenAlex
- W2810683054
- Cited by
- 34
- References
- 3
- FWCI
- 4.26
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Respiratory Compensation Point and the Deoxygenation Break Point Are Not Valid Surrogates for Critical Power and Maximum Lactate Steady State. https://app.cochat.ai/papers/10.1249/mss.0000000000001699
- The paper
- BROXTERMAN, R. M., CRAIG, J. C., & RICHARDSON, R. S. (2018). The Respiratory Compensation Point and the Deoxygenation Break Point Are Not Valid Surrogates for Critical Power and Maximum Lactate Steady State. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000001699
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.