A Simple Method to Quantify the V˙O2 Mean Response Time of Ramp-Incremental Exercise
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
During ramp-incremental exercise, the mean response time (MRT) of oxygen uptake (V˙O 2) represents the time delay for changes in muscle V˙O 2 to be reflected at the level of the mouth and is generally calculated by linear (MRT LIN) and monoexponential (τ′) fitting of V˙O 2 data. However, these methods yield MRT values that are highly variable from test-to-test. Purpose: Therefore, we examined the validity and the reproducibility of a novel method to calculate the MRT. Methods: On two occasions, 12 healthy men (age, 30 ± 10 yr; V˙O 2max: 4.14 ± 0.47 L·min−1, 53.5 ± 7.3 mL·kg−1·min−1) performed a ramp-incremental cycling test (30 W·min−1) that was preceded by a step transition to 100 W. The ramp power output corresponding to the steady-state V˙O 2 at 100 W was determined and the difference between that power output and 100 W was converted to time to quantify the MRT (MRT SS). Results: The values of MRT LIN, τ′, and MRT SS were 28 ± 16 s, 27 ± 12 s, and 26 ± 11 s, respectively, which were not different (P > 0.05) from each other. However, compared to the MRT parameters derived from the fitting-based methods, MRT SS had a higher correlation coefficient (R = 0.87) and a smaller coefficient of variation (15% ± 9%) from test-to-test. Conclusions: In conclusion, the novel method proposed in the current study was found to be valid and highly reproducible in a test-retest design. Therefore, we advocate the use of this approach when a precise and accurate determination of the MRT is needed to properly align the V˙O 2 data with power output during ramp-incremental exercise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
KEIR, D. A., POGLIAGHI, S., & MURIAS, J. M. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001698 · Cited by 65
Self-citation
Cited by
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
A Critical Evaluation of Current Methods for Exercise Prescription in Women and Men
IANNETTA, D., INGLIS, E. C., MATTU, A. T., FONTANA, F. Y., POGLIAGHI, S., KEIR, D. A., & MURIAS, J. M. (2020) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000002147 · Cited by 236
Self-citationIdentification of Non-Invasive Exercise Thresholds: Methods, Strategies, and an Online App
Keir, D. A., Iannetta, D., Mattioni Maturana, F., Kowalchuk, J. M., & Murias, J. M. (2022) · Sports Medicine · doi:10.1007/s40279-021-01581-z · Cited by 193
Self-citationCaen, K., Bourgois, J. G., Stassijns, E., & Boone, J. (2022) · European Journal of Applied Physiology · doi:10.1007/s00421-022-04942-2 · Cited by 41
Yogev, A., Arnold, J., Clarke, D., Guenette, J. A., Sporer, B. C., & Koehle, M. S. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.818733 · Cited by 35
Metadata
- Authors
- IANNETTA, D., MURIAS, J. M., & KEIR, D. A.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2019-05
- Volume
- 51
- Issue
- 5
- Pages
- 1080-1086
- ISSN
- 0195-9131 (ISSN-L)
- 1530-0315
- OpenAlex
- W2908688501
- Cited by
- 78
- References
- 2
- FWCI
- 9.73
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Simple Method to Quantify the V˙O2 Mean Response Time of Ramp-Incremental Exercise. https://app.cochat.ai/papers/10.1249/mss.0000000000001880
- The paper
- IANNETTA, D., MURIAS, J. M., & KEIR, D. A. (2019). A Simple Method to Quantify the V˙O2 Mean Response Time of Ramp-Incremental Exercise. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0000000000001880
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.