The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Determination of Critical Power Using a 3-min All-out Cycling Test
Open accessAbstract
PURPOSE: We tested the hypothesis that the power output attained at the end of a 3-min all-out cycling test would be equivalent to critical power. METHODS: Ten habitually active subjects performed a ramp test, two 3-min all-out tests against a fixed resistance to establish the end-test power (EP) and the work done above the EP (WEP), and five constant-work rate tests to establish the critical power (CP) and the curvature constant parameter (W') using the work-time and 1/time models. RESULTS: The power output in the 3-min trial declined to a steady level within 135 s. The EP was 287 +/- 55 W, which was not significantly different from, and highly correlated with, CP (287 +/- 56 W; P = 0.37, r = 0.99). The standard error for the estimation of CP using EP was approximately 6 W, and in 8 of 10 cases, EP agreed with CP to within 5 W. Similarly, the WEP derived from the 3-min test (15.0 +/- 4.7 kJ) was not significantly different from, and correlated with, W' (16.0 +/- 3.8 kJ; P = 0.35; r = 0.84). CONCLUSIONS: During a 3-min all-out cycling test, power output declined to a stable value in approximately the last 45 s, and this power output was not significantly different from the independently measured critical power.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
Cited by
Translating Fatigue to Human Performance
ENOKA, R. M., & DUCHATEAU, J. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000929 · Cited by 948
An Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
The anaerobic threshold: 50+ years of controversy
Poole, D. C., Rossiter, H. B., Brooks, G. A., & Gladden, L. B. (2021) · The Journal of Physiology · doi:10.1113/jp279963 · Cited by 312
The maximal metabolic steady state: redefining the ‘gold standard’
Jones, A. M., Burnley, M., Black, M. I., Poole, D. C., & Vanhatalo, A. (2019) · Physiological Reports · doi:10.14814/phy2.14098 · Cited by 298
Self-citationJones, A. M., & Vanhatalo, A. (2017) · Sports Medicine · doi:10.1007/s40279-017-0688-0 · Cited by 259
Metadata
- Authors
- VANHATALO, A., DOUST, J. H., & BURNLEY, M.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2007-03
- Volume
- 39
- Issue
- 3
- Pages
- 548-555
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2047923268
- Cited by
- 356
- References
- 1
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Determination of Critical Power Using a 3-min All-out Cycling Test. https://app.cochat.ai/papers/10.1249/mss.0b013e31802dd3e6
- The paper
- VANHATALO, A., DOUST, J. H., & BURNLEY, M. (2007). Determination of Critical Power Using a 3-min All-out Cycling Test. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e31802dd3e6
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.