The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Determination of Critical Power Using a 3-min All-out Cycling Test
Open accessAbstract
PURPOSE: We tested the hypothesis that the power output attained at the end of a 3-min all-out cycling test would be equivalent to critical power. METHODS: Ten habitually active subjects performed a ramp test, two 3-min all-out tests against a fixed resistance to establish the end-test power (EP) and the work done above the EP (WEP), and five constant-work rate tests to establish the critical power (CP) and the curvature constant parameter (W') using the work-time and 1/time models. RESULTS: The power output in the 3-min trial declined to a steady level within 135 s. The EP was 287 +/- 55 W, which was not significantly different from, and highly correlated with, CP (287 +/- 56 W; P = 0.37, r = 0.99). The standard error for the estimation of CP using EP was approximately 6 W, and in 8 of 10 cases, EP agreed with CP to within 5 W. Similarly, the WEP derived from the 3-min test (15.0 +/- 4.7 kJ) was not significantly different from, and correlated with, W' (16.0 +/- 3.8 kJ; P = 0.35; r = 0.84). CONCLUSIONS: During a 3-min all-out cycling test, power output declined to a stable value in approximately the last 45 s, and this power output was not significantly different from the independently measured critical power.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A new method for detecting anaerobic threshold by gas exchange
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.60.6.2020 · Cited by 4,103
THE WORK CAPACITY OF A SYNERGIC MUSCULAR GROUP
MONOD, H., & SCHERRER, J. (1965) · Ergonomics · doi:10.1080/00140136508930810 · Cited by 872
Metabolic and respiratory profile of the upper limit for prolonged exercise in man
POOLE, D. C., WARD, S. A., GARDNER, G. W., & WHIPP, B. J. (1988) · Ergonomics · doi:10.1080/00140138808966766 · Cited by 779
The Slow Component of Oxygen Uptake Kinetics in Humans
GAESSER, G. A., & POOLE, D. C. (1996) · Exercise and Sport Sciences Reviews · doi:10.1249/00003677-199600240-00004 · Cited by 663
A test to determine parameters of aerobic function during exercise
Whipp, B. J., Davis, J. A., Torres, F., & Wasserman, K. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.50.1.217 · Cited by 657
Critical power as a measure of physical work capacity and anaerobic threshold
MORITANI, T., NAGATA, A., DEVRIES, H. A., & MURO, M. (1981) · Ergonomics · doi:10.1080/00140138108924856 · Cited by 578
The maximally attainable V̇o2during exercise in humans: the peak vs. maximum issue
Day, J. R., Rossiter, H. B., Coats, E. M., Skasick, A., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00024.2003 · Cited by 447
The Critical Power Concept: A Review
Hill, D. W. (1993) · Sports Medicine · doi:10.2165/00007256-199316040-00003 · Cited by 418
On-line computer analysis and breath-by-breath graphical display of exercise function tests.
Beaver, W. L., Wasserman, K., & Whipp, B. J. (1973) · Journal of Applied Physiology · doi:10.1152/jappl.1973.34.1.128 · Cited by 318
The slow component of O2 uptake kinetics during heavy exercise
WHIPP, B. J. (1994) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199411000-00005 · Cited by 285
A 3-min All-Out Test to Determine Peak Oxygen Uptake and the Maximal Steady State
BURNLEY, M., DOUST, J. H., & VANHATALO, A. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000232024.06114.a6 · Cited by 258
Self-citationDetermination of maximal lactate steady state response in selected sports events
BENEKE, R., & von DUVILLARD, S. P. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199602000-00013 · Cited by 247
Poole, D. C., Ward, S. A., & Whipp, B. J. (1990) · European Journal of Applied Physiology and Occupational Physiology · doi:10.1007/bf02388623 · Cited by 236
Maximal lactate steady state, critical power and EMG during cycling
Pringle, J., & Jones, A. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0703-4 · Cited by 224
The relationship between power and the time to achieve &OV0312;O2max
HILL, D. W., POOLE, D. C., & SMITH, J. C. (2002) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200204000-00023 · Cited by 220
The critical power and related whole-body bioenergetic models
Morton, R. H. (2006) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0088-2 · Cited by 201
Smith, C. G. M., & Jones, A. M. (2001) · European Journal of Applied Physiology · doi:10.1007/s004210100384 · Cited by 186
The validity of the lactate minimum test for determination of the maximal lactate steady state
JONES, A. M., & DOUST, J. H. (1998) · Medicine& Science in Sports & Exercise · doi:10.1097/00005768-199808000-00020 · Cited by 186
Self-citationA metabolic limit on the ability to make up for lost time in endurance events
Fukuba, Y., & Whipp, B. J. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.2.853 · Cited by 127
Physiological responses during exercise to exhaustion at critical power
Brickley, G., Doust, J. H., & Williams, C. A. (2002) · European Journal of Applied Physiology · doi:10.1007/s00421-002-0706-1 · Cited by 122
Self-citationAccumulated oxygen deficit during supramaximal all-out and constant intensity exercise
Gastin, P. B., COSTILL, D. L., Lawson, D. L., Krzeminski, K., & McConell, G. K. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199502000-00016 · Cited by 112
The Curvature Constant Parameter of the Power-Duration Curve for Varied-Power Exercise
Fukuba, Y., Miura, A., Endo, M. Y., Kan, A., Yanagawa, K., & Whipp, B. J. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000079047.84364.70 · Cited by 103
Intensity-dependent tolerance to exercise after attaining V o 2 max in humans
Coats, E. M., Rossiter, H. B., Day, J. R., Miura, A., Fukuba, Y., & Whipp, B. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01142.2002 · Cited by 93
Oxygen deficits incurred during 45, 60, 75 and 90-s maximal cycling on an air-braked ergometer
Withers, R. T., van der Ploeg, G. E., & Finn, J. P. (1993) · European Journal of Applied Physiology · doi:10.1007/bf00376665 · Cited by 65
Validity of the two-parameter model in estimating the anaerobic work capacity
Dekerle, J., Brickley, G., Hammond, A. J. P., PRINGLE, J. S. M., & Carter, H. (2005) · European Journal of Applied Physiology · doi:10.1007/s00421-005-0074-8 · Cited by 53
Gastin, P. B., & Lawson, D. L. (1994) · European Journal of Applied Physiology · doi:10.1007/bf00392039 · Cited by 49
Validity of a Single-Visit Protocol to Estimate the Maximum Lactate Steady State
Kilding, A. E., & JONES, A. M. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000181691.72432.a1 · Cited by 40
Cited by
Translating Fatigue to Human Performance
ENOKA, R. M., & DUCHATEAU, J. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000929 · Cited by 948
The Quantification of Training Load, the Training Response and the Effect on Performance
Borresen, J., & Ian Lambert, M. (2009) · Sports Medicine · doi:10.2165/11317780-000000000-00000 · Cited by 743
Critical Power: Implications for Determination of V˙O2max and Exercise Tolerance
JONES, A. M., VANHATALO, A., BURNLEY, M., MORTON, R. H., & POOLE, D. C. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d9cf7f · Cited by 549
Self-citationCritical Power: An Important Fatigue Threshold in Exercise Physiology
POOLE, D. C., BURNLEY, M., VANHATALO, A., ROSSITER, H. B., & JONES, A. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000939 · Cited by 535
Self-citationAn Examination and Critique of Current Methods to Determine Exercise Intensity
Jamnick, N. A., Pettitt, R. W., Granata, C., Pyne, D. B., & Bishop, D. J. (2020) · Sports Medicine · doi:10.1007/s40279-020-01322-8 · Cited by 424
Metadata
- Authors
- VANHATALO, A., DOUST, J. H., & BURNLEY, M.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2007-03
- Volume
- 39
- Issue
- 3
- Pages
- 548-555
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2047923268
- Cited by
- 356
- References
- 27
- FWCI
- 8.21
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.