Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 186

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

The validity of the lactate minimum test for determination of the maximal lactate steady state

JONES, ANDREW M., DOUST, JONATHAN H.·1998·Medicine& Science in Sports & Exercise

Abstract

PURPOSE: The purpose of this study was to investigate the validity of the lactate minimum test ([Lac-]BMIN) in the determination of the velocity at the maximal lactate steady state (V-MLSS), and to identify those physiological factors most closely associated with 8-km running performance. METHODS: Thirteen trained male runners (VO2max range 53-67 mL.kg-1.min-1) took part in an 8-km simulated race on flat roads and completed a comprehensive battery of laboratory tests. RESULTS: Performance velocity was most strongly correlated with the estimated running velocity at VO2max (r = 0.93) and with V-MLSS (r = 0.92) and velocity at lactate threshold (V-Tlac) (r= 0.93). The running velocity at the ventilatory threshold (V-Tvent) (r = 0.81) and the [Lac-]BMIN (r = 0.83) also produced good correlations with performance velocity. Performance running velocity (mean +/- SEM 16.0 +/- 0.3 km.h-1) was not significantly different from V-MLSS (15.7 +/- 0.3 km.h-1). The running velocity at [Lac-]BMIN (14.9 +/- 0.2 km.h-1) was not significantly different from the V-Tlac (15.1 +/- 0.3 km.h-1) or V-Tvent (14.9 +/- 0.2 km.h-1) was not significantly different from the V-Tlac (15.1 +/- 0.3 km.h-1) or V-Tvent (14.9 +/- 0.3 km.h-1) but was significantly lower than the V-MLSS (P < 0.05). The [Lac-]BMIN provided the lowest correlation with V-MLSS (r = 0.61) and the worst estimate of V-MLSS (SEE = 0.75 km.h-1) compared with the other measures of lactate accumulation. The V-Tlac was not significantly different from V-MLSS and provided the highest correlation (r = 0.94) and a close estimate (SEE = 0.33 km.h-1) of the V-MLSS. CONCLUSIONS: It is concluded that of the measures studied relating to blood lactate accumulation during submaximal exercise, V-Tlac provides the best estimate of the V-MLSS and the V-Tlac had equal predictive power for 8-km race performance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1097/00005768-199808000-00020

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 186

Metadata

Authors
JONES, A. M., & DOUST, J. H.
Venue
Medicine& Science in Sports & Exercise
Published
1998-08
Volume
30
Issue
8
Pages
1304-1313
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2071569718
Cited by
186
References
6
FWCI
2.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The validity of the lactate minimum test for determination of the maximal lactate steady state. https://app.cochat.ai/papers/10.1097/00005768-199808000-00020
The paper
JONES, A. M., & DOUST, J. H. (1998). The validity of the lactate minimum test for determination of the maximal lactate steady state. Medicine& Science in Sports & Exercise. https://doi.org/10.1097/00005768-199808000-00020

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.