CoChat

Influence of Sensor Ingestion Timing on Consistency of Temperature Measures

GOODMAN, DANIEL A., KENEFICK, ROBERT W., CADARETTE, BRUCE S., CHEUVRONT, SAMUEL N. · 2009 · Medicine & Science in Sports & Exercise
Cited by 45

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE: The validity and the reliability of using intestinal temperature (T int) via ingestible temperature sensors (ITS) to measure core body temperature have been demonstrated. However, the effect of elapsed time between ITS ingestion and T int measurement has not been thoroughly studied. METHODS: Eight volunteers (six men and two women) swallowed ITS 5 h (ITS-5) and 29 h (ITS-29) before 4 h of varying intensity activity. T int was measured simultaneously from both ITS, and T int differences between the ITS-5 and the ITS-29 over the 4 h of activity were plotted and compared relative to a meaningful threshold of acceptance (+/-0.25 degrees C). The percentage of time in which the differences between paired ITS (ITS-5 vs ITS-29) were greater than or less than the threshold of acceptance was calculated. RESULTS: T int values showed no systematic bias, were normally distributed, and ranged from 36.94 degrees C to 39.24 degrees C. The maximum T int difference between paired ITS was 0.83 degrees C with a minimum difference of 0.00 degrees C. The typical magnitude of the differences (SE of the estimate) was 0.24 degrees C, and these differences were uniform across the entire range of observed temperatures. Paired T int measures fell outside of the threshold of acceptance 43.8% of the time during the 4 h of activity. CONCLUSIONS: The differences between ITS-5 and ITS-29 were larger than the threshold of acceptance during a substantial portion of the observed 4-h activity period. Ingesting an ITS more than 5 h before activity will not completely eliminate confounding factors but may improve accuracy and consistency of core body temperature.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e31818a0eef

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 45

Metadata

Authors
GOODMAN, D. A., KENEFICK, R. W., CADARETTE, B. S., & CHEUVRONT, S. N.
Venue
Medicine & Science in Sports & Exercise
Published
2009-03
Volume
41
Issue
3
Pages
597-602
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2019015794
Cited by
45
References
4
FWCI
1.97
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Influence of Sensor Ingestion Timing on Consistency of Temperature Measures. https://app.cochat.ai/papers/10.1249/mss.0b013e31818a0eef
The paper
GOODMAN, D. A., KENEFICK, R. W., CADARETTE, B. S., & CHEUVRONT, S. N. (2009). Influence of Sensor Ingestion Timing on Consistency of Temperature Measures. Medicine & Science in Sports & Exercise. https://doi.org/10.1249/mss.0b013e31818a0eef

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.