Assessing Physical Activity in Persons with Rheumatoid Arthritis Using Accelerometry
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
PURPOSE: To investigate empirically if the nonwear threshold and the "valid day" definition for accelerometer data from the general adult US population are appropriate for accelerometer data from persons with rheumatoid arthritis (RA). METHODS: This study analyzed data from 107 persons with RA participating in the baseline (2006-2008) accelerometer assessment from two studies with common inclusion/exclusion criteria. We examined candidate nonwear thresholds ranging from 20 to 300 min of zero activity count. The effect of the selected nonwear threshold is examined in regard to 1) mean daily activity counts, 2) activity counts per wear hour, 3) mean daily minutes of moderate to vigorous physical activity (MVPA) according to count thresholds that occur in 10-min bouts, and 4) MVPA bout minutes per wear hour. The effect of ranging the definition of a valid day of accelerometer data from 8 h of wear time to 12 h on data retention was also examined. RESULTS: In 737 d of accelerometer data analyzed, the average daily wear hours increased with length of nonwear threshold of allowed continuous zero activity count minutes. The mean number of nonzero activity count minutes increased with the chosen nonwear threshold until it stabilized at 478 min.d of activity, which corresponded to the 90-min nonwear threshold. Choosing this threshold and requiring at least 10 h of wear time to constitute a valid day were associated with 92.8% of days of collected data defined as "valid." CONCLUSIONS: Data supported increasing the allowed nonwear threshold in this RA subpopulation from 60 to 90 min, while retaining the 10-h day as the measure of the "valid day."
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 1×
“Numerous validation studies have focused on interpreting accelerometer counts by defining thresholds that correspond to light-, moderate-, and vigorous-intensity physical activities (8,21).”
BackgroundThe impact of momentary pain and fatigue on physical activity in women with osteoarthritis
Murphy, S. L., Smith, D. M., Clauw, D. J., & Alexander, N. B. (2008) · Arthritis Care & Research · doi:10.1002/art.23710 · Cited by 134 · cited 1×
“T he objective measurement of physical activity (PA) using accelerometry is now used in large-scale epidemiologic studies (22) and clinical trials including studies of persons with arthritis (7,10,16).”
Method
Cited by
Objective physical activity measurement in the osteoarthritis initiative: Are guidelines being met?
Dunlop, D. D., Song, J., Semanik, P. A., Chang, R. W., Sharma, L., Bathon, J. M., Eaton, C. B., Hochberg, M. C., Jackson, R. D., Kwoh, C. K., et al. (2011) · Arthritis & Rheumatism · doi:10.1002/art.30562 · Cited by 240
“These methods are consistent with accelerometry methodology used in the general population and have been validated in patients with rheumatic disease (17,28,30).”
MethodSelf-citationSedentary Behavior and Physical Function: Objective Evidence From the Osteoarthritis Initiative
Lee, J., Chang, R. W., Ehrlich‐Jones, L., Kwoh, C. K., Nevitt, M., Semanik, P. A., Sharma, L., Sohn, M., Song, J., & Dunlop, D. D. (2015) · Arthritis Care & Research · doi:10.1002/acr.22432 · Cited by 173
Self-citationThe clinical utility of accelerometry in patients with rheumatoid arthritis
Prioreschi, A., Hodkinson, B., Avidon, I., Tikly, M., & McVeigh, J. A. (2013) · Rheumatology · doi:10.1093/rheumatology/ket216 · Cited by 86
Towards an understanding of physical activity in people with chronic low back pain
Griffin, D. W. (2013) · University of Limerick · doi:10.34961/7893 · Cited by 1
Metadata
- Authors
- SEMANIK, P., SONG, J., CHANG, R. W., MANHEIM, L., AINSWORTH, B., & DUNLOP, D.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2010-08
- Volume
- 42
- Issue
- 8
- Pages
- 1493-1501
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2047291983
- Cited by
- 74
- References
- 2
- FWCI
- 3.23
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.