Validation of the ActiGraph Two-Regression Model for Predicting Energy Expenditure
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
PURPOSE: The purpose of this study was to validate a two-regression model for predicting energy expenditure (EE) from ActiGraph GT1M accelerometer-generated activity counts using a whole-room indirect calorimeter and the doubly labeled water (DLW) technique. We also investigated if a low-pass filter (LPF) approach would improve the model's accuracy in the minute-to-minute EE prediction. METHODS: Thirty-four healthy volunteers (age = 20-67 yr, body mass index = 19.3-52.1 kg.m) spent approximately 24 h in a room calorimeter while wearing a GT1M monitor and performed structured and self-selected activities followed by overnight sleep. The EE predicted by the models and expressed in metabolic equivalents (MET-minutes) during waking times was compared with the room calorimeter-measured EE. A subset of volunteers (n = 22) completed a 14-d DLW protocol in free living while wearing an ActiGraph. The average daily EE predicted by the models (MET-minutes) was compared with the DLW. RESULTS: Compared with the room calorimeter, the two-regression model overpredicted EE by 10.2% +/- 11.4% (1282 +/- 125 and 1174 +/- 152 MET.min, P < 0.001) and time spent in moderate physical activity (PA) by 36.9 +/- 46.0 min while underestimating the time spent in light PA by -48.3 +/- 55.0 min (P < 0.05). The LPF reduced the squared and mean absolute error in the EE prediction (P < 0.05) but not the prediction error in time spent in moderate or light PA (both P > 0.05). The EE measured by DLW (2108 +/- 358 MET.min.d) and predicted by both filtered and unfiltered models (2104 +/- 218 and 2192 +/- 228 MET.min.d, respectively) were similar (P > 0.05). CONCLUSIONS: The two-regression model with LPF showed good agreement with total EE measured using room calorimeter and DLW. However, the individual variability in assessing time spent in sedentary, low, and moderate PA intensities and related EE remains significant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825 · cited 1×
“Early efforts focused on developing a single linear relationship between EE and activity recorded in arbitrary units (counts) (6,10,23), which has been shown to be challenging (19).”
BackgroundAmount of Time Spent in Sedentary Behaviors in the United States, 2003-2004
Matthews, C. E., Chen, K. Y., Freedson, P. S., Buchowski, M. S., Beech, B. M., Pate, R. R., & Troiano, R. P. (2008) · American Journal of Epidemiology · doi:10.1093/aje/kwm390 · Cited by 2,631 · cited 2×
“This may be an important limitation of the LPF, since there is growing interest in characterizing the duration and intensity of sedentary PA behaviors (8,13).”
BackgroundResultSelf-citationObjectively Measured Sedentary Time, Physical Activity, and Metabolic Risk
Healy, G. N., Wijndaele, K., Dunstan, D. W., Shaw, J. E., Salmon, J., Zimmet, P. Z., & Owen, N. (2008) · Diabetes Care · doi:10.2337/dc07-1795 · Cited by 1,100 · cited 1×
“This may be an important limitation of the LPF, since there is growing interest in characterizing the duration and intensity of sedentary PA behaviors (8,13).”
BackgroundPhysical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Staudenmayer, J., Pober, D., Crouter, S., Bassett, D., & Freedson, P. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00465.2009 · Cited by 361
Zakeri, I., Adolph, A. L., Puyau, M. R., Vohra, F. A., & Butte, N. F. (2008) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01163.2007 · Cited by 80 · cited 2×
“Recently, several alternative approaches such as multiple linear regressions (9), power models (3), polynomial fits (20,28), and machine learning (16,18,22,29) have been developed.”
BackgroundMethod
Cited by
Migueles, J. H., Cadenas-Sanchez, C., Ekelund, U., Delisle Nyström, C., Mora-Gonzalez, J., Löf, M., Labayen, I., Ruiz, J. R., & Ortega, F. B. (2017) · Sports Medicine · doi:10.1007/s40279-017-0716-0 · Cited by 1,868
Validation of Accelerometer Wear and Nonwear Time Classification Algorithm
CHOI, L., LIU, Z., MATTHEWS, C. E., & BUCHOWSKI, M. S. (2011) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181ed61a3 · Cited by 1,804
Self-citationStrath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
van Hees, V. T., Gorzelniak, L., Dean León, E. C., Eder, M., Pias, M., Taherian, S., Ekelund, U., Renström, F., Franks, P. W., Horsch, A., et al. (2013) · PLoS ONE · doi:10.1371/journal.pone.0061691 · Cited by 926
Methods of Measurement in epidemiology: Sedentary Behaviour
Atkin, A. J., Gorely, T., Clemes, S. A., Yates, T., Edwardson, C., Brage, S., Salmon, J., Marshall, S. J., & Biddle, S. J. (2012) · International Journal of Epidemiology · doi:10.1093/ije/dys118 · Cited by 518
Metadata
- Authors
- ROTHNEY, M. P., BRYCHTA, R. J., MEADE, N. N., CHEN, K. Y., & BUCHOWSKI, M. S.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2010-09
- Volume
- 42
- Issue
- 9
- Pages
- 1785-1792
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2150852771
- Cited by
- 65
- References
- 6
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.