The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Accuracy of Armband Monitors for Measuring Daily Energy Expenditure in Healthy Adults
Abstract
INTRODUCTION: There is a need to develop accurate devices for measuring daily energy expenditure under free-living conditions, particularly given our current obesity epidemic. PURPOSE: The purpose of the present study was to evaluate the validity of energy expenditure estimates from two portable armband devices, the SenseWear Pro3 Armband (SWA) monitor and the SenseWear Mini Armband (Mini) monitor, under free-living conditions. METHODS: Participants in the study (30 healthy adults aged 24-60 yr) wore both monitors for 14 consecutive days, including while sleeping. Criterion values for total energy expenditure (TEE) were determined using doubly labeled water (DLW), the established criterion standard method for free-living energy expenditure assessment. RESULTS: The average TEE estimates were within 112 kcal·d−¹ for the SWA and within 22 kcal·d−¹ for the Mini, but the absolute error rates (computed as the average absolute value of the individual errors) were similar for the two monitors (SWA = 8.1% ± 6.8%, Mini = 8.3% ± 6.5%). Using intraclass correlation (ICC) analysis, significant agreements were found between the SWA and DLW estimates of energy expenditure (ICC = 0.80, 95% CI = 0.89-0.70) and between the Mini and DLW (ICC = 0.85, 95% CI = 0.92-0.76). Graphical plots of the DLW TEE values against the difference between DLW and monitor estimates of TEE showed that the agreement was consistent across a range of TEE values. CONCLUSIONS: The SenseWear Pro3 and the SenseWear Mini armbands show promise for accurately measuring daily energy expenditure under free-living conditions. However, more work is needed to improve the ability of these monitors to accurately measure energy expenditure at higher levels of expenditure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638
Physical Activity Assessment With Accelerometers: An Evaluation Against Doubly Labeled Water
Plasqui, G., & Westerterp, K. R. (2007) · Obesity · doi:10.1038/oby.2007.281 · Cited by 654
Measurement of Energy Expenditure in Free-Living Humans by Using Doubly Labeled Water
Schoeller, D. A. (1988) · The Journal of Nutrition · doi:10.1093/jn/118.11.1278 · Cited by 602
Evaluation of a portable device to measure daily energy expenditure in free-living adults
St-Onge, M., Mignault, D., Allison, D. B., & Rabasa-Lhoret, R. (2007) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/85.3.742 · Cited by 397
Evaluation of the SenseWear Pro Armband™ to Assess Energy Expenditure during Exercise
JAKICIC, J. M., MARCUS, M., GALLAGHER, K. I., RANDALL, C., THOMAS, E., GOSS, F. L., & ROBERTSON, R. J. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000126805.32659.43 · Cited by 362
Validity of a Multi-Sensor Armband in Estimating Rest and Exercise Energy Expenditure
FRUIN, M. L., & RANKIN, J. W. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000128144.91337.38 · Cited by 342
Field Validation of the MTI Actigraph and BodyMedia Armband Monitor Using the IDEEA Monitor
Welk, G. J., McClain, J. J., Eisenmann, J. C., & Wickel, E. E. (2007) · Obesity · doi:10.1038/oby.2007.624 · Cited by 244
Self-citationComparison of Activity Monitors to Estimate Energy Cost of Treadmill Exercise
KING, G. A., TORRES, N., POTTER, C., BROOKS, T. J., & COLEMAN, K. J. (2004) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000132379.09364.f8 · Cited by 238
Measuring Free‐Living Energy Expenditure and Physical Activity with Triaxial Accelerometry
Plasqui, G., Joosen, A. M. C. P., Kester, A. D., Goris, A. H. C., & Westerterp, K. R. (2005) · Obesity Research · doi:10.1038/oby.2005.165 · Cited by 183
Determinants of total daily energy expenditure: variability in physical activity
Rising, R., Harper, I., Fontvielle, A., Ferraro, R., Spraul, M., & Ravussin, E. (1994) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/59.4.800 · Cited by 168
Thermic effect of food in humans: methods and results from use of a respiratory chamber
Tataranni, P., Larson, D., Snitker, S., & Ravussin, É. (1995) · American Journal of Clinical Nutrition · doi:10.1093/ajcn/61.5.1013 · Cited by 135
Comparison of doubly labeled water with respirometry at low- and high-activity levels
Westerterp, K. R., Brouns, F. J. P. H., Saris, W. H. M., & ten Hoor, F. (1988) · Journal of Applied Physiology · doi:10.1152/jappl.1988.65.1.53 · Cited by 102
Energy Expenditure Estimated by Accelerometry and Doubly Labeled Water: Do They Agree?
Leenders, N., Sherman, W. M., & Nagaraja, H. N. (2006) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000235883.94357.95 · Cited by 76
Hustvedt, B., Christophersen, A., Johnsen, L. R., Tomten, H., McNeill, G., Haggarty, P., & Lövö, A. (2004) · British Journal Of Nutrition · doi:10.1079/bjn20041272 · Cited by 71
Löf, M., Hannestad, U., & Forsum, E. (2003) · British Journal Of Nutrition · doi:10.1079/bjn2003975 · Cited by 52
Influence of body composition on physical activity validation studies using doubly labeled water
Mâsse, L. C., Fulton, J. E., Watson, K. L., Mahar, M. T., Meyers, M. C., & Wong, W. W. (2004) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00901.2003 · Cited by 51
Cited by
Strath, S. J., Kaminsky, L. A., Ainsworth, B. E., Ekelund, U., Freedson, P. S., Gary, R. A., Richardson, C. R., Smith, D. T., & Swartz, A. M. (2013) · Circulation · doi:10.1161/01.cir.0000435708.67487.da · Cited by 1,029
Trepanowski, J. F., Kroeger, C. M., Barnosky, A., Klempel, M. C., Bhutani, S., Hoddy, K. K., Gabel, K., Freels, S., Rigdon, J., Rood, J., et al. (2017) · JAMA Internal Medicine · doi:10.1001/jamainternmed.2017.0936 · Cited by 645
Self-citationPractical Guide to Measuring Physical Activity
Sylvia, L. G., Bernstein, E. E., Hubbard, J. L., Keating, L., & Anderson, E. J. (2014) · Journal of the Academy of Nutrition and Dietetics · doi:10.1016/j.jand.2013.09.018 · Cited by 637
Ferguson, T., Rowlands, A. V., Olds, T., & Maher, C. (2015) · International Journal of Behavioral Nutrition and Physical Activity · doi:10.1186/s12966-015-0201-9 · Cited by 468
Hutchison, A. T., Regmi, P., Manoogian, E. N. C., Fleischer, J. G., Wittert, G. A., Panda, S., & Heilbronn, L. K. (2019) · Obesity · doi:10.1002/oby.22449 · Cited by 466
Metadata
- Authors
- JOHANNSEN, D. L., CALABRO, M. A., STEWART, J., FRANKE, W., ROOD, J. C., & WELK, G. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2010-11
- Volume
- 42
- Issue
- 11
- Pages
- 2134-2140
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2075842143
- Cited by
- 424
- References
- 17
- FWCI
- 20.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.