Asymmetry of Quadriceps Muscle Oxygenation during Elite Short-Track Speed Skating
The DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.
Abstract
Purpose It has been suggested that, because of the low sitting position in short-track speed skating, muscle blood flow is restricted, leading to decreases in tissue oxygenation. Therefore, wearable wireless-enabled near-infrared spectroscopy (NIRS) technology was used to monitor changes in quadriceps muscle blood volume and oxygenation during a 500-m race simulation in short-track speed skaters. Methods Six elite skaters, all of Olympic standard (age = 23 ± 1.8 yr, height = 1.8 ± 0.1 m, mass = 80.1 ± 5.7 kg, midthigh skinfold thickness = 7 ± 2 mm), were studied. Subjects completed a 500-m race simulation time trial (TT). Whole-body oxygen consumption was simultaneously measured with muscle oxygenation in right and left vastus lateralis as measured by NIRS. Results Mean time for race completion was 44.8 ± 0.4 s. VO2 peaked 20 s into the race. In contrast, muscle tissue oxygen saturation (TSI%) decreased and plateaued after 8 s. Linear regression analysis showed that right leg TSI% remained constant throughout the rest of the TT (slope value = 0.01), whereas left leg TSI% increased steadily (slope value = 0.16), leading to a significant asymmetry (P Conclusions NIRS was shown to be a viable tool for wireless monitoring of muscle oxygenation. The asymmetry in muscle desaturation observed on the two legs in short-track speed skating has implications for training and performance.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Bilateral differences have been found by Hesford et al. (2012), who examined asymmetry between the SmO2 of the left and right quadriceps in ice skaters, and found differences depending on the muscle side that was being exerted more.”
From Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle (2018) · cites this paper as Hesford et al. (2012)
Citations
Cites
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997 · cited 2×
“Although the limitations of NIRS measurements have been highlighted in several reviews (11,25), many of these are overcome by the study design and subject group used.”
BackgroundMethodProgress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600 · cited 1×
“changes in exercising muscle, and this work has been reviewed extensively (11,15,21,25,37).”
BackgroundTissue oxygenation monitor using NIR spatially resolved spectroscopy:
Suzuki, S., Takasaki, S., Ozaki, T., & Kobayashi, Y. (1999) · SPIE Proceedings · doi:10.1117/12.356862 · Cited by 484 · cited 1×
“Spatially resolved spectroscopy (SRS) probes deeper into tissue and minimizes interference from movement and light scattering artifacts (33) and provides a measurement of absolute tissue oxygen saturation.”
BackgroundVan Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430 · cited 1×
“If there are no opposing changes in red cell velocity, NIR-measured changes in blood volume will reflect the change in volume blood flow and hence in oxygen delivery to the muscle tissue (35).”
BackgroundTime-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle
Chance, B., Nioka, S., Kent, J., McCully, K., Fountain, M., Greenfeld, R., & Holtom, G. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90076-0 · Cited by 329 · cited 1×
“Photon migration and Monte Carlo simulations suggest a maximum penetration depth of half the distance between emitter and detector, that is, 20 mm for this device (7,38); for a review of this, see Hamaoka et al.”
BackgroundHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329 · cited 1×
“changes in exercising muscle, and this work has been reviewed extensively (11,15,21,25,37).”
BackgroundPerspectives in Exercise Science and Sports Medicine
Lamb, D. R. (1988) · Cited by 263
Spatial heterogeneity of quadriceps muscle deoxygenation kinetics during cycle exercise
Koga, S., Poole, D. C., Ferreira, L. F., Whipp, B. J., Kondo, N., Saitoh, T., Ohmae, E., & Barstow, T. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00627.2007 · Cited by 184 · cited 1×
“It has previously been shown that quadriceps muscle oxygenation is nonuniform during exercise (17,18,20,22), so precise and consistent optode placement was crucial.”
BackgroundThe use of near infrared spectroscopy in sports medicine.
Quaresima, V., Lepanto, R., & Ferrari, M. (2003) · PubMed · Cited by 143
Kalliokoski, K. K., Oikonen, V., Takala, T. O., Sipilä, H., Knuuti, J., & Nuutila, P. (2001) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2001.280.6.e1015 · Cited by 140 · cited 1×
“However, it has also been shown that, during a higher-intensity exercise, the spatial heterogeneity of oxygenation changes is greatly reduced (3,18) and that quadriceps blood flow is less heterogeneous during a high-intensity exercise in highly trained individuals, such as the subjects of the present study (16).”
Background
Research works printed but not linked: 2
- Dekoning, 1995, The start in speed skatingfrom running to gliding., Med Sci Sports Exerc, 27, 1703
- Quaresima, 1999, Oxygenation kinetics of different leg muscle groups measured during a 100-m sprint run by a portable near-infrared photometer., Ital J Sports Exerc, 6, 20
Cited by
Wearable Training-Monitoring Technology: Applications, Challenges, and Opportunities
Cardinale, M., & Varley, M. C. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2016-0423 · Cited by 221
Self-citationMuscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
“In particular, muscle load (regional mechanical constraints imposed by changing muscle contraction during uphill or downhill running [78], skating [63] or alpine skiing [15]) and HR (systemic cardiovascular strain) could be combined to accurately measure internal workload.”
BackgroundMcManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
Self-citationFarzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107
Performance Characteristics of Long-Track Speed Skaters: A Literature Review
Konings, M. J., Elferink-Gemser, M. T., Stoter, I. K., van der Meer, D., Otten, E., & Hettinga, F. J. (2014) · Sports Medicine · doi:10.1007/s40279-014-0298-z · Cited by 79
“In addition, recent (short-track) on-ice muscle oxygenation studies revealed an asymmetry in deoxygenation in short-track skaters after the start, as the right leg remains more deoxygenated than the left leg in the corners [66, 67].”
Background
Metadata
- Authors
- HESFORD, C. M., LAING, S. J., CARDINALE, M., & COOPER, C. E.
- Affiliations
- University of Essex (GB)
- Bangor University (GB)
- University of Aberdeen (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2012-03
- Volume
- 44
- Issue
- 3
- Pages
- 501-508
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1977113525
- Semantic Scholar
- c30b1eb9e7899a2cdc3fbd8d619d601567957fa3
- Cited by
- 63
- References
- 41
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 7 · 2023: 6 · 2022: 4 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 8 · 2017: 7 · 2016: 4 · 2015: 2 · 2014: 3 · 2013: 5 · 2012: 3
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Open Access at Essex (University of Essex) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- short track speed skating, interlimb asymmetry, muscle blood volume, tissue oxygen saturation, near-infrared spectroscopy, cornering, whole-body oxygen consumption
- MeSH terms
- Blood Volume, Humans, Leg, Male, Monte Carlo Method, Oxygen Consumption, Regional Blood Flow, Skating, Time Factors, Video Recording, Linear Models, Spectroscopy, Near-Infrared, Quadriceps Muscle, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.