Asymmetry of Quadriceps Muscle Oxygenation during Elite Short-Track Speed Skating
The DOI matches its Crossref record; 40 of the 41 references it cites were found in a registry or an index.
Abstract
Purpose It has been suggested that, because of the low sitting position in short-track speed skating, muscle blood flow is restricted, leading to decreases in tissue oxygenation. Therefore, wearable wireless-enabled near-infrared spectroscopy (NIRS) technology was used to monitor changes in quadriceps muscle blood volume and oxygenation during a 500-m race simulation in short-track speed skaters. Methods Six elite skaters, all of Olympic standard (age = 23 ± 1.8 yr, height = 1.8 ± 0.1 m, mass = 80.1 ± 5.7 kg, midthigh skinfold thickness = 7 ± 2 mm), were studied. Subjects completed a 500-m race simulation time trial (TT). Whole-body oxygen consumption was simultaneously measured with muscle oxygenation in right and left vastus lateralis as measured by NIRS. Results Mean time for race completion was 44.8 ± 0.4 s. VO2 peaked 20 s into the race. In contrast, muscle tissue oxygen saturation (TSI%) decreased and plateaued after 8 s. Linear regression analysis showed that right leg TSI% remained constant throughout the rest of the TT (slope value = 0.01), whereas left leg TSI% increased steadily (slope value = 0.16), leading to a significant asymmetry (P Conclusions NIRS was shown to be a viable tool for wireless monitoring of muscle oxygenation. The asymmetry in muscle desaturation observed on the two legs in short-track speed skating has implications for training and performance.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Bilateral differences have been found by Hesford et al. (2012), who examined asymmetry between the SmO2 of the left and right quadriceps in ice skaters, and found differences depending on the muscle side that was being exerted more.”
From Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle (2018) · cites this paper as Hesford et al. (2012)
Citations
Cites
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997 · cited 2×
“Although the limitations of NIRS measurements have been highlighted in several reviews (11,25), many of these are overcome by the study design and subject group used.”
BackgroundMethodProgress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600 · cited 1×
“changes in exercising muscle, and this work has been reviewed extensively (11,15,21,25,37).”
BackgroundTissue oxygenation monitor using NIR spatially resolved spectroscopy:
Suzuki, S., Takasaki, S., Ozaki, T., & Kobayashi, Y. (1999) · SPIE Proceedings · doi:10.1117/12.356862 · Cited by 484 · cited 1×
“Spatially resolved spectroscopy (SRS) probes deeper into tissue and minimizes interference from movement and light scattering artifacts (33) and provides a measurement of absolute tissue oxygen saturation.”
BackgroundVan Beekvelt, M. C. P., Colier, W. N. J. M., Wevers, R. A., & Van Engelen, B. G. M. (2001) · Journal of Applied Physiology · doi:10.1152/jappl.2001.90.2.511 · Cited by 430 · cited 1×
“If there are no opposing changes in red cell velocity, NIR-measured changes in blood volume will reflect the change in volume blood flow and hence in oxygen delivery to the muscle tissue (35).”
BackgroundTime-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle
Chance, B., Nioka, S., Kent, J., McCully, K., Fountain, M., Greenfeld, R., & Holtom, G. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90076-0 · Cited by 329 · cited 1×
“Photon migration and Monte Carlo simulations suggest a maximum penetration depth of half the distance between emitter and detector, that is, 20 mm for this device (7,38); for a review of this, see Hamaoka et al.”
BackgroundHamaoka, T., McCully, K. K., Quaresima, V., Yamamoto, K., & Chance, B. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2805437 · Cited by 329 · cited 1×
“changes in exercising muscle, and this work has been reviewed extensively (11,15,21,25,37).”
BackgroundPerspectives in Exercise Science and Sports Medicine
Lamb, D. R. (1988) · Cited by 263
Spatial heterogeneity of quadriceps muscle deoxygenation kinetics during cycle exercise
Koga, S., Poole, D. C., Ferreira, L. F., Whipp, B. J., Kondo, N., Saitoh, T., Ohmae, E., & Barstow, T. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00627.2007 · Cited by 184 · cited 1×
“It has previously been shown that quadriceps muscle oxygenation is nonuniform during exercise (17,18,20,22), so precise and consistent optode placement was crucial.”
BackgroundThe use of near infrared spectroscopy in sports medicine.
Quaresima, V., Lepanto, R., & Ferrari, M. (2003) · PubMed · Cited by 143
Kalliokoski, K. K., Oikonen, V., Takala, T. O., Sipilä, H., Knuuti, J., & Nuutila, P. (2001) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2001.280.6.e1015 · Cited by 140 · cited 1×
“However, it has also been shown that, during a higher-intensity exercise, the spatial heterogeneity of oxygenation changes is greatly reduced (3,18) and that quadriceps blood flow is less heterogeneous during a high-intensity exercise in highly trained individuals, such as the subjects of the present study (16).”
BackgroundHomma, S., Fukunaga, T., & Kagaya, A. (1996) · Journal of Biomedical Optics · doi:10.1117/12.252417 · Cited by 123 · cited 1×
“Another commonly cited limitation of the use of NIRS is the influence of adipose tissue thickness on the measured parameters (8,14,30).”
BackgroundPereira, M., Gomes, P. S. C., & BHAMBHANI, Y. N. (2007) · Sports Medicine · doi:10.2165/00007256-200737070-00005 · Cited by 118 · cited 1×
“changes in exercising muscle, and this work has been reviewed extensively (11,15,21,25,37).”
BackgroundEvidence for restricted muscle blood flow during speed skating
FOSTER, C., RUNDELL, K. W., SNYDER, A. C., STRAY-GUNDERSEN, J., KEMKERS, G., THOMETZ, N., BROKER, J., & KNAPP, E. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199910000-00012 · Cited by 89 · cited 6×
“Although previous studies have investigated the metabolic effects of the ‘‘low sitting’’ position adopted in speed skating (13,29), the results presented in this article display the effects of the differing lower limb and trunk positions adopted during each lap, and the race as a whole, rather than solely comparing ‘‘…”
BackgroundMethodResultInfluentialEndofîbrosis of the Iliac Arteries: an Underestimated Problem
Feugier, P., & Chevalier, J.-M. (2004) · Acta chirurgica Belgica · doi:10.1080/00015458.2004.11679635 · Cited by 74 · cited 1×
“However, because none of the athletes in our subject group have been diagnosed with this condition, or reported any of the common symptoms (12), it is unlikely that such a condition would have impaired quadriceps blood flow in this particular subject group.”
BackgroundHemoglobin/myoglobin oxygen desaturation during Alpine skiing
SZMEDRA, L., Im, J., Nioka, S., Chance, B., & Rundell, K. W. (2001) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-200102000-00010 · Cited by 71 · cited 2×
“The development of portable NIRS devices has allowed local muscle measurements to be made away from a laboratory setting to investigate local muscle changes in sports such as speed skating (13), alpine skiing (34), and running (4,23).”
BackgroundShadgan, B., Reid, W. D., Gharakhanlou, R., Stpublisher-ids, L., & Macnab, A. J. (2009) · Spectroscopy An International Journal · doi:10.1155/2009/719604 · Cited by 66
Nonuniform Quadriceps O2 Consumption Revealed by Near Infrared Multipoint Measurements
Quaresima, V., Colier, W. N. J. M., van der Sluijs, M. C., & Ferrari, M. (2001) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2001.5292 · Cited by 61 · cited 1×
“It has previously been shown that quadriceps muscle oxygenation is nonuniform during exercise (17,18,20,22), so precise and consistent optode placement was crucial.”
BackgroundHemoglobin/myoglobin desaturation during speed skating
RUNDELL, K. W., NIOKA, S., & CHANCE, B. (1997) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199702000-00014 · Cited by 61 · cited 3×
“For example, the unique ‘‘low sitting’’ position adopted during speed skating has been shown to elicit increased blood lactate (13), to lower submaximal V̇O2 uptake (27), and to lead to a combination of reduced blood volume change and greater deoxygenation in the quadriceps muscles (29) when compared with upright skat…”
BackgroundResultGastrocnemius Medialis and Vastus Lateralis Oxygenation during Whole-Body Vibration Exercise
CARDINALE, M., FERRARI, M., & QUARESIMA, V. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31803084d8 · Cited by 60 · cited 2×
“SRS-derived measure of tissue oxygen saturation measured by the transportable tissue oximeters made by Hamamatsu Photonics Japan (5,6).”
BackgroundMethodSelf-citationBuchheit, M., Laursen, P. B., & Ahmaidi, S. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.91625.2008 · Cited by 55 · cited 2×
“The development of portable NIRS devices has allowed local muscle measurements to be made away from a laboratory setting to investigate local muscle changes in sports such as speed skating (13), alpine skiing (34), and running (4,23).”
BackgroundMethodMuscle tissue oxygenation and VEGF in VO2‐matched vibration and squatting exercise
Rittweger, J., Moss, A., Colier, W. N. J. M., Stewart, C. E., & Degens, H. (2010) · Clinical Physiology and Functional Imaging · doi:10.1111/j.1475-097x.2010.00937.x · Cited by 54 · cited 1×
“This model has previously been used to investigate muscle oxygenation and hemodynamics (4,26,31).”
MethodBender, M. H., Schep, G., de Vries, W. R., Hoogeveen, A. R., & Wijn, P. F. F. (2004) · Sports Medicine · doi:10.2165/00007256-200434070-00002 · Cited by 54 · cited 1×
“Approximately one in five endurance-trained speed skaters develop sports-related flow limitations in the iliac arteries (2), which could reasonably be expected to affect nearinfrared measurements made in the quadriceps muscle group.”
BackgroundThe start in speed skating: from running to gliding
de Koning, J. J., THOMAS, R., Berger, M., GROOT, G. D., & Schenau, G. J. V. I. (1995) · Medicine & Science in Sports & Exercise · doi:10.1249/00005768-199512000-00019 · Cited by 52 · cited 1×
“The first half lap, in which the skater accelerates from a standing start through a ‘‘running’’ action, as has been previously described (10), was completed in 6.”
BackgroundOxygen Transport to Tissue XXXI
Takahashi, E., & Bruley, D. F. (2010) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-1241-1 · Cited by 52
Physiological and biomechanical comparison of roller skating and speed skating on ice
de Boer, R. W., VOS, E. J., Hutter, W., de Groot, G., & Schenau, G. J. V. I. (1987) · European Journal of Applied Physiology · doi:10.1007/bf00635371 · Cited by 50 · cited 1×
“The cumulative effect is that, although sufficient muscle groups are recruited, their aerobic capacity cannot be fully used (9); hence, a high anaerobic energy contribution is necessitated.”
BackgroundYang, Y., Soyemi, O. O., Landry, M. R., & Soller, B. R. (2005) · Optics Express · doi:10.1364/opex.13.001570 · Cited by 47 · cited 1×
“Photon migration and Monte Carlo simulations suggest a maximum penetration depth of half the distance between emitter and detector, that is, 20 mm for this device (7,38); for a review of this, see Hamaoka et al.”
BackgroundEffect of Exercise Protocol on Deoxy[Hb + Mb]: Incremental Step versus Ramp Exercise
BOONE, J., KOPPO, K., BARSTOW, T. J., & BOUCKAERT, J. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181c0ecea · Cited by 46 · cited 1×
“However, it has also been shown that, during a higher-intensity exercise, the spatial heterogeneity of oxygenation changes is greatly reduced (3,18) and that quadriceps blood flow is less heterogeneous during a high-intensity exercise in highly trained individuals, such as the subjects of the present study (16).”
BackgroundEffects of drafting during short-track speed skating
Rundell, K. W. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199606000-00016 · Cited by 46 · cited 1×
“Cornering forces in a 1000-m race have been calculated at 866 N in the short track as opposed to 482 N for the long track (28).”
BackgroundCompromised oxygen uptake in speed skaters during treadmill in-line skating
Rundell, K. W. (1996) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199601000-00023 · Cited by 46
Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1646417 · Cited by 45 · cited 1×
“Recent studies have reported regional heterogeneity in vastus lateralis oxygenation as measured by NIRS (17,24).”
Bae, S. Y., Hamaoka, T., Katsumara, T., Shiga, T., Ohno, H., & Haga, S. (2000) · International Journal of Sports Medicine · doi:10.1055/s-2000-8880 · Cited by 44 · cited 1×
“Similar NIRS profiles have been seen in other laboratorybased NIRS studies where exercise is started at high power (1).”
BackgroundVastus Lateralis O2 Desaturation in Response to Fast and Short Maximal Contraction
CETTOLO, V., FERRARI, M., BIASINI, V., & QUARESIMA, V. (2007) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181453476 · Cited by 40 · cited 3×
“SRS-derived measure of tissue oxygen saturation measured by the transportable tissue oximeters made by Hamamatsu Photonics Japan (5,6).”
BackgroundMethodKennedy, M. D., Haykowsky, M. J., Boliek, C. A., Esch, B. T., Scott, J. M., & Warburton, D. E. (2006) · Dynamic Medicine · doi:10.1186/1476-5918-5-8 · Cited by 38 · cited 2×
“It has previously been shown that quadriceps muscle oxygenation is nonuniform during exercise (17,18,20,22), so precise and consistent optode placement was crucial.”
BackgroundReduced Heterogeneity of Muscle Deoxygenation during Heavy Bicycle Exercise
KIME, R., IM, J., MOSER, D., LIN, Y., NIOKA, S., KATSUMURA, T., & CHANCE, B. (2005) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000155401.81284.76 · Cited by 37 · cited 2×
“It has previously been shown that quadriceps muscle oxygenation is nonuniform during exercise (17,18,20,22), so precise and consistent optode placement was crucial.”
BackgroundShadgan, B., Reid, W. D., Gharakhanlou, R., Stpublisher-ids, L., & Macnab, A. J. (2009) · doi:10.3233/spe-2009-0391 · Cited by 35 · cited 1×
“This model has previously been used to investigate muscle oxygenation and hemodynamics (4,26,31).”
MethodQuadriceps Oxygenation during Isometric Exercise in Sailing
Vogiatzis, I., Tzineris, D., Athanasopoulos, D., Georgiadou, O., & Geladas, N. D. (2007) · International Journal of Sports Medicine · doi:10.1055/s-2007-964993 · Cited by 35 · cited 1×
“hiking action in sailing (36) and alpine skiing (34).”
BackgroundImage Registration of Structural and Physiological MR Images of Abnormal Anatomy
Mang, A., Cámara, Ó., Caseiras, G. B., Crum, W. R., Schnabel, J. A., Buzug, T. M., Thornton, J. S., Jäger, H. R., & Hawkes, D. J. (2007) · Springer eBooks · doi:10.1007/978-3-540-68764-1_35 · Cited by 24
Cooper, C. E., Penfold, S.-M., Elwell, C. E., & Angus, C. (2010) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4419-1241-1_25 · Cited by 21 · cited 1×
“Another commonly cited limitation of the use of NIRS is the influence of adipose tissue thickness on the measured parameters (8,14,30).”
BackgroundSelf-citationKoepp, K., & Janot, J. M. (2008) · The Journal of Strength and Conditioning Research · doi:10.1519/jsc.0b013e318161931f · Cited by 19
Algorithms for muscle oxygenation monitoring corrected for adipose tissue thickness
Geraskin, D., Platen, P., Franke, J., & Kohl‐Bareis, M. (2007) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.727854 · Cited by 10 · cited 1×
“Another commonly cited limitation of the use of NIRS is the influence of adipose tissue thickness on the measured parameters (8,14,30).”
Background
Research works printed but not linked: 2
- Dekoning, 1995, The start in speed skatingfrom running to gliding., Med Sci Sports Exerc, 27, 1703
- Quaresima, 1999, Oxygenation kinetics of different leg muscle groups measured during a 100-m sprint run by a portable near-infrared photometer., Ital J Sports Exerc, 6, 20
Cited by
Wearable Training-Monitoring Technology: Applications, Challenges, and Opportunities
Cardinale, M., & Varley, M. C. (2017) · International Journal of Sports Physiology and Performance · doi:10.1123/ijspp.2016-0423 · Cited by 221
Self-citationMuscle Oximetry in Sports Science: A Systematic Review
Perrey, S., & Ferrari, M. (2018) · Sports Medicine · doi:10.1007/s40279-017-0820-1 · Cited by 220
“In particular, muscle load (regional mechanical constraints imposed by changing muscle contraction during uphill or downhill running [78], skating [63] or alpine skiing [15]) and HR (systemic cardiovascular strain) could be combined to accurately measure internal workload.”
BackgroundMcManus, C. J., Collison, J., & Cooper, C. E. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.1.015007 · Cited by 205
Self-citationFarzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107
Performance Characteristics of Long-Track Speed Skaters: A Literature Review
Konings, M. J., Elferink-Gemser, M. T., Stoter, I. K., van der Meer, D., Otten, E., & Hettinga, F. J. (2014) · Sports Medicine · doi:10.1007/s40279-014-0298-z · Cited by 79
“In addition, recent (short-track) on-ice muscle oxygenation studies revealed an asymmetry in deoxygenation in short-track skaters after the start, as the right leg remains more deoxygenated than the left leg in the corners [66, 67].”
Background
Metadata
- Authors
- HESFORD, C. M., LAING, S. J., CARDINALE, M., & COOPER, C. E.
- Affiliations
- University of Essex (GB)
- Bangor University (GB)
- University of Aberdeen (GB)
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2012-03
- Volume
- 44
- Issue
- 3
- Pages
- 501-508
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W1977113525
- Semantic Scholar
- c30b1eb9e7899a2cdc3fbd8d619d601567957fa3
- Cited by
- 63
- References
- 41
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 7 · 2023: 6 · 2022: 4 · 2021: 5 · 2020: 3 · 2019: 2 · 2018: 8 · 2017: 7 · 2016: 4 · 2015: 2 · 2014: 3 · 2013: 5 · 2012: 3
- FWCI
- 9.39
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Medicine & Science in Sports & Exercise (publishedVersion)
- PubMed (publishedVersion)
- UCL Discovery (University College London) (submittedVersion)
- Open Access at Essex (University of Essex) (submittedVersion)
- Topics
- Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
- Health Sciences › Medicine › Physiology (medical) › Exercise and Physiological Responses
- Keywords
- short track speed skating, interlimb asymmetry, muscle blood volume, tissue oxygen saturation, near-infrared spectroscopy, cornering, whole-body oxygen consumption
- MeSH terms
- Blood Volume, Humans, Leg, Male, Monte Carlo Method, Oxygen Consumption, Regional Blood Flow, Skating, Time Factors, Video Recording, Linear Models, Spectroscopy, Near-Infrared, Quadriceps Muscle, Young Adult
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.