Statistical Considerations in the Analysis of Accelerometry-Based Activity Monitor Data
The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
We review and discuss three statistical aspects of accelerometer-based estimates of physical activity energy expenditure (PAEE):1) the nature of the relationship between accelerometer output and PAEE;2) statistical aspects of calibration studies; and 3) two specialized statistical methods that are applicable to the problem of measurement error modeling and missing data methods.We call for a continuing development of statistical methods that use more characteristics of the accelerometer signal to estimate PAEE, advocate the use of bias and SE statistics and inclusion of cross-validation in accelerometer research designs, and encourage more efforts to understand systematic and random errors in accelerometer-based estimates of PAEE.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical Activity in the United States Measured by Accelerometer
TROIANO, R. P., BERRIGAN, D., DODD, K. W., MÂSSE, L. C., TILERT, T., & MCDOWELL, M. (2008) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e31815a51b3 · Cited by 7,638 · cited 1×
“(27), who used accelerometers and linear regression methods to estimate PAEE from 2003–2004 National Health and Nutrition Examination Survey data.”
MethodCalibration of the Computer Science and Applications, Inc. accelerometer
FREEDSON, P. S., MELANSON, E., & SIRARD, J. (1998) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199805000-00021 · Cited by 3,825
Staudenmayer, J., Pober, D., Crouter, S., Bassett, D., & Freedson, P. (2009) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00465.2009 · Cited by 361
Self-citationAccelerometer output and MET values of common physical activities
KOZEY, S. L., LYDEN, K., HOWE, C. A., STAUDENMAYER, J. W., & FREEDSON, P. S. (2010) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3181d479f2 · Cited by 174
Self-citation
Cited by
Actigraph GT3X: Validation and Determination of Physical Activity Intensity Cut Points
Santos-Lozano, A., Santín-Medeiros, F., Cardon, G., Torres-Luque, G., Bailón, R., Bergmeir, C., Ruiz, J., Lucia, A., & Garatachea, N. (2013) · International Journal of Sports Medicine · doi:10.1055/s-0033-1337945 · Cited by 383
Calibration and Validation of Wearable Monitors
BASSETT, D. R., ROWLANDS, A., & TROST, S. G. (2012) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0b013e3182399cf7 · Cited by 292
A Primer on the Use of Equivalence Testing for Evaluating Measurement Agreement
DIXON, P. M., SAINT-MAURICE, P. F., KIM, Y., HIBBING, P., BAI, Y., & WELK, G. J. (2018) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000001481 · Cited by 227
Aittasalo, M., Vähä-Ypyä, H., Vasankari, T., Husu, P., Jussila, A.-M., & Sievänen, H. (2015) · BMC Sports Science, Medicine and Rehabilitation · doi:10.1186/s13102-015-0010-0 · Cited by 126
Chowdhury, E. A., Western, M. J., Nightingale, T. E., Peacock, O. J., & Thompson, D. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171720 · Cited by 118
Metadata
- Authors
- STAUDENMAYER, J., ZHU, W., & CATELLIER, D. J.
- Venue
- Medicine & Science in Sports & Exercise
- Published
- 2012-01
- Volume
- 44
- Issue
- 1S
- Pages
- S61-S67
- ISSN
- 0195-9131 (ISSN-L)
- OpenAlex
- W2314289569
- Cited by
- 110
- References
- 4
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.