CoChat

Validity, Practical Utility, and Reliability of the activPAL™ in Preschool Children

Open access
DAVIES, GWYNETH, REILLY, JOHN J., MCGOWAN, AMY J., DALL, PHILIPPA M., GRANAT, MALCOLM H., PATON, JAMES Y. · 2012 · Medicine & Science in Sports & Exercise
Cited by 116

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

PURPOSE: With the increasing global prevalence of childhood obesity, it is important to have appropriate measurement tools for investigating factors (e.g., sedentary time) contributing to positive energy balance in early childhood. For preschool children, single-unit monitors such as the activPAL™ are promising. However, validation is required because activity patterns differ from adults. METHODS: Thirty preschool children participated in a validation study. Children undertaking usual nursery activity while wearing an activPAL™ 1 h were recorded using a video camera. Video (criterion method) was analyzed on a second-by-second basis to categorize posture and activity. This was compared with the corresponding activPAL™ output. In a subsequent substudy investigating practical utility and reliability, 20 children wore an activPAL™ for seven consecutive 24-h periods. RESULTS: A total of 97,750 s of direct observation from 30 children were categorized as sit/lie (46%), stand (35%), and walk (16%); with 3% of time in non-sit/lie/upright postures (e.g., crawl/crouch/kneel-up). Sensitivity for the overall total time-matched seconds detected as activPAL™ "sit/lie" was 86.7%, specificity was 97.1%, and positive predictive value was 96.3%. For individual children, the median (interquartile range) sensitivity for activPAL™ sit/lie was 92.8% (76.1%-97.4%), specificity was 97.3% (94.9%-99.2%), and positive predictive value was 97.0% (91.5%-99.1%). The activPAL™ underestimated total time spent sitting (mean difference = -4.4%, P < 0.01) and overestimated time standing (mean difference = 7.1%, P < 0.01). There was no difference in overall percent time categorized as "walk" (P = 0.2). The monitors were well tolerated by children during a 7-d period of free-living activity. In the reliability study, at least 5 d of monitoring was required to obtain an intraclass correlation coefficient of ≥ 0.8 for time spent "sit/lie" according to activPAL™ output. CONCLUSIONS: The activPAL™ had acceptable validity, practical utility, and reliability for the measurement of posture and activity during free-living activities in preschool children.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e31823b1dc7

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

Metadata

Authors
DAVIES, G., REILLY, J. J., MCGOWAN, A. J., DALL, P. M., GRANAT, M. H., & PATON, J. Y.
Venue
Medicine & Science in Sports & Exercise
Published
2012-04
Volume
44
Issue
4
Pages
761-768
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2158247287
Cited by
116
References
5
FWCI
5.97
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.