CoChat

Knee Extensor Fatigue Threshold Is Related to Whole-Body V˙O2max

DE RUITER, CORNELIS J., MAAS, ELLEN A., WESSELING, MARISKA G. H., DE HAAN, ARNOLD · 2012 · Medicine & Science in Sports & Exercise

The DOI matches its Crossref record; 31 of the 32 references it cites were found in a registry or an index.

Abstract

Purpose Above a given exercise intensity, rapid muscle fatigue will occur. We explored the possibility of assessing torque threshold for peripheral fatigue during single-legged repetitive isometric knee extensor exercise. We hypothesized this fatigue threshold to be related to the general aerobic fitness level and the so-called "critical torque" (CT) established with a recently validated 5-min all-out test. Methods Seventeen healthy men (VO(2max) = 44.7-69.6 mL·kg(-1)·min(-1)) performed six submaximal (20%-55% maximal voluntary contraction [MVC]) 5-min bouts of 60 repetitive contractions (3-s on, 2-s off). Torque was changed between bouts in steps of 5% MVC to estimate the highest intensity (fatigue threshold) at which average changes in rsEMG, EMG median power frequency, and tissue deoxygenation (near-infrared spectroscopy) of the three superficial knee extensor muscles were still Results Fatigue threshold (40.0% ± 8.1% MVC) was related (r(2) = 0.57, P Conclusions Performing submaximal bouts of knee extensor contractions, while monitoring EMG and deoxygenation, seems a feasible manner to estimate an aerobic capacity-related exercise intensity of peripheral fatigue onset. This test may be used to evaluate changes in endurance capacity of single muscle groups, without the necessity for all-out testing, which could be problematic with frail subjects.

Overview

Integrity signals

Registry

Crossref · 10.1249/mss.0b013e318249d701

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 31 references

Cited by

Metadata

Authors
DE RUITER, C. J., MAAS, E. A., WESSELING, M. G. H., & DE HAAN, A.
Affiliations
Vrije Universiteit Amsterdam (NL)
Venue
Medicine & Science in Sports & Exercise
Published
2012-07
Volume
44
Issue
7
Pages
1366-1374
ISSN
0195-9131 (ISSN-L)
OpenAlex
W2328355364
Cited by
7
References
32
Citations by year
2026: 1 · 2023: 1 · 2019: 1 · 2017: 1 · 2016: 1 · 2015: 1 · 2013: 1
FWCI
1.56
Type
journal article
Language
en
Open access
closed
Locations
  • Medicine & Science in Sports & Exercise (publishedVersion)
  • PubMed (publishedVersion)
  • VU Research Portal (publishedVersion)
  • Data Archiving and Networked Services (DANS) (submittedVersion)
Topics
  • Health Sciences › Medicine › Physiology (medical) › Cardiovascular and exercise physiology
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Sports Performance and Training
  • Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
Keywords
fatigue threshold, VO2max, cardiorespiratory fitness, critical torque, all-out test, muscular endurance, ventilatory threshold, muscle deoxygenation
MeSH terms
Adult, Electric Stimulation, Exercise Test, Humans, Isometric Contraction, Knee, Male, Oxygen Consumption, Physical Fitness, Ergometry, Muscle, Skeletal, Muscle Fatigue, Torque, Young Adult

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.