CoChat

Comparative Effects of an Angiotensin II Receptor Blocker (ARB)/Diuretic vs. ARB/Calcium-Channel Blocker Combination on Uncontrolled Nocturnal Hypertension Evaluated by Information and Communication Technology-Based Nocturnal Home Blood Pressure Monitoring ― The NOCTURNE Study ―

Open access
Kario, Kazuomi, Tomitani, Naoko, Kanegae, Hiroshi, Ishii, Hajime, Uchiyama, Kazuaki, Yamagiwa, Kayo, Shiraiwa, Toshihiko, Katsuya, Tomohiro, Yoshida, Tetsuro, Kanda, Kiyomi, Hasegawa, Shinji, Hoshide, Satoshi · 2017 · Circulation Journal
Cited by 69

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

BACKGROUND: Nocturnal blood pressure (BP) is an independent risk factor of cardiovascular events. The NOCTURNE study, a multicenter, randomized controlled trial (RCT) using our recently developed information and communication technology (ICT) nocturnal home BP monitoring (HBPM) device, was performed to compare the nocturnal HBP-lowering effects of differential ARB-based combination therapies in 411 Japanese patients with nocturnal hypertension (HT). METHODS AND RESULTS: Patients with nocturnal BP ≥120/70 mmHg at baseline even under ARB therapy (100 mg irbesartan daily) were enrolled. The ARB/CCB combination therapy (irbesartan 100 mg+amlodipine 5 mg) achieved a significantly greater reduction in nocturnal home systolic BP (primary endpoint) than the ARB/diuretic combination (daily irbesartan 100 mg+trichlormethiazide 1 mg) (-14.4 vs. -10.5 mmHg, P<0.0001), independently of urinary sodium excretion and/or nocturnal BP dipping status. However, the change in nocturnal home systolic BP was comparable among the post-hoc subgroups with higher salt sensitivity (diabetes, chronic kidney disease, and elderly patients). CONCLUSIONS: This is the first RCT demonstrating the feasibility of clinical assessment of nocturnal BP by ICT-nocturnal HBPM. The ARB/CCB combination was shown to be superior to ARB/diuretic in patients with uncontrolled nocturnal HT independently of sodium intake, despite the similar impact of the 2 combinations in patients with higher salt sensitivity.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1253/circj.cj-17-0109

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

Metadata

Authors
Kario, K., Tomitani, N., Kanegae, H., Ishii, H., Uchiyama, K., Yamagiwa, K., Shiraiwa, T., Katsuya, T., Yoshida, T., Kanda, K., Hasegawa, S., & Hoshide, S.
Venue
Circulation Journal
Published
2017
Volume
81
Issue
7
Pages
948-957
ISSN
  • 1346-9843 (ISSN-L)
  • 1347-4820
OpenAlex
W2595554261
Cited by
69
References
6
FWCI
6.89
Type
journal article
Language
en
Open access
diamond

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.