Guidelines for the Clinical Use of 24 Hour Ambulatory Blood Pressure Monitoring (ABPM) (JCS 2010) - Digest Version -
Open accessThe DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Purpose of the GuidelinesThe Guidelines for the Clinical Use of 24 Hour Ambulatory Blood Pressure Monitoring (ABPM) was first released as a 1998-1999 Japanese Circulation Society (JCS) report to describe the results of clinical research and clinical findings based on the clinical experience and provide guidance on the clinical use of 24 hour ABPM, which had begun to be used widely in the clinical settings.In 2008, ABPM was endorsed in the National Health Insurance (NHI) in Japan, and has been used as a tool in general practice.The present guidelines are an update of the previous guidelines of 1998-1999.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Staessen, J. A. (1999) · JAMA · doi:10.1001/jama.282.6.539 · Cited by 1,592
Dolan, E., Stanton, A., Thijs, L., Hinedi, K., Atkins, N., McClory, S., Hond, E. D., McCormack, P., Staessen, J. A., & O’Brien, E. (2005) · Hypertension · doi:10.1161/01.hyp.0000170138.56903.7a · Cited by 1,227
Sega, R., Facchetti, R., Bombelli, M., Cesana, G., Corrao, G., Grassi, G., & Mancia, G. (2005) · Circulation · doi:10.1161/01.cir.0000160923.04524.5b · Cited by 1,009
Parati, G., Pomidossi, G., Albini, F., Malaspina, D., & Mancia, G. (1987) · Journal of Hypertension · doi:10.1097/00004872-198702000-00013 · Cited by 952
Prognostic accuracy of day versus night ambulatory blood pressure: a cohort study
Boggia, J., Li, Y., Thijs, L., Hansen, T. W., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Kuznetsova, T., Torp-Pedersen, C., et al. (2007) · The Lancet · doi:10.1016/s0140-6736(07)61538-4 · Cited by 887
Fagard, R. H., Celis, H., Thijs, L., Staessen, J. A., Clement, D. L., De Buyzere, M. L., & De Bacquer, D. A. (2008) · Hypertension · doi:10.1161/hypertensionaha.107.100727 · Cited by 742
Prognostic value of 24-hour blood pressure variability
Frattola, A., Parati, G., Cuspidi, C., Albini, F., & Mancia, G. (1993) · Journal of Hypertension · doi:10.1097/00004872-199310000-00019 · Cited by 659
Relation Between Nocturnal Decline in Blood Pressure and Mortality The Ohasama Study
Ohkubo, T. (1997) · American Journal of Hypertension · doi:10.1016/s0895-7061(97)00274-4 · Cited by 491
Hansen, T. W., Thijs, L., Li, Y., Boggia, J., Kikuya, M., Björklund-Bodegård, K., Richart, T., Ohkubo, T., Jeppesen, J., Torp-Pedersen, C., et al. (2010) · Hypertension · doi:10.1161/hypertensionaha.109.140798 · Cited by 480
Kikuya, M., Ohkubo, T., Asayama, K., Metoki, H., Obara, T., Saito, S., Hashimoto, J., Totsune, K., Hoshi, H., Satoh, H., et al. (2005) · Hypertension · doi:10.1161/01.hyp.0000152079.04553.2c · Cited by 417
Prevalence and Factors Associated With Circadian Blood Pressure Patterns in Hypertensive Patients
de la Sierra, A., Redon, J., Banegas, J. R., Segura, J., Parati, G., Gorostidi, M., de la Cruz, J. J., Sobrino, J., Llisterri, J. L., Alonso, J., et al. (2009) · Hypertension · doi:10.1161/hypertensionaha.108.124008 · Cited by 379
Ben-Dov, I. Z., Kark, J. D., Ben-Ishay, D., Mekler, J., Ben-Arie, L., & Bursztyn, M. (2007) · Hypertension · doi:10.1161/hypertensionaha.107.087262 · Cited by 367
Diagnostic Thresholds for Ambulatory Blood Pressure Monitoring Based on 10-Year Cardiovascular Risk
Kikuya, M., Hansen, T. W., Thijs, L., Björklund-Bodegård, K., Kuznetsova, T., Ohkubo, T., Richart, T., Torp-Pedersen, C., Lind, L., Ibsen, H., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.662254 · Cited by 314
Continuous vs intermittent blood pressure measurements in estimating 24-hour average blood pressure.
di Rienzo, M., Grassi, G., Pedotti, A., & Mancia, G. (1983) · Hypertension · doi:10.1161/01.hyp.5.2.264 · Cited by 239
Prognostic Value of Nocturnal Blood Pressure Reduction in Resistant Hypertension
Muxfeldt, E. S., Cardoso, C. R. L., & Salles, G. F. (2009) · Archives of Internal Medicine · doi:10.1001/archinternmed.2009.68 · Cited by 155
Obara, T., Ohkubo, T., Funahashi, J., Kikuya, M., Asayama, K., Metoki, H., Oikawa, T., Hashimoto, J., Totsune, K., & Imai, Y. (2005) · Journal of Hypertension · doi:10.1097/01.hjh.0000178334.33352.56 · Cited by 112
Cited by
European Society of hypertension position paper on ambulatory blood pressure monitoring
O’Brien, E., Parati, G., Stergiou, G., Asmar, R., Beilin, L., Bilo, G., Clement, D., de la Sierra, A., de Leeuw, P., Dolan, E., et al. (2013) · Journal of Hypertension · doi:10.1097/hjh.0b013e328363e964 · Cited by 1,419
Piezoelectric Dynamics of Arterial Pulse for Wearable Continuous Blood Pressure Monitoring
Yi, Z., Liu, Z., Li, W., Ruan, T., Chen, X., Liu, J., Yang, B., & Zhang, W. (2022) · Advanced Materials · doi:10.1002/adma.202110291 · Cited by 265
Cuff-Less and Continuous Blood Pressure Monitoring: A Methodological Review
Sharma, M., Barbosa, K., Ho, V., Griggs, D., Ghirmai, T., Krishnan, S., Hsiai, T., Chiao, J.-C., & Cao, H. (2017) · Technologies · doi:10.3390/technologies5020021 · Cited by 226
An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement
Zheng, Y.-L., Yan, B. P., Zhang, Y.-T., & Poon, C. C. Y. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2318779 · Cited by 177
Kario, K., Shin, J., Chen, C., Buranakitjaroen, P., Chia, Y., Divinagracia, R., Nailes, J., Hoshide, S., Siddique, S., Sison, J., et al. (2019) · The Journal of Clinical Hypertension · doi:10.1111/jch.13652 · Cited by 164
Metadata
- Authors
- JCS Joint Working Group
- Venue
- Circulation Journal
- Publisher
- Japanese Circulation Society
- Published
- 2012
- Volume
- 76
- Issue
- 2
- Pages
- 508-519
- ISSN
- 1346-9843 (ISSN-L)
- 1347-4820
- OpenAlex
- W4236785602
- Cited by
- 101
- References
- 16
- FWCI
- 5.95
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.