An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement

Zheng, Ya-Li, Yan, Bryan P., Zhang, Yuan-Ting, Poon, Carmen C. Y.·2014·IEEE Transactions on Biomedical Engineering

Abstract

24-h blood pressure (BP) has significant prognostic value for cardiovascular risk screening, but the present BP devices are mainly cuff-based, which are unsuitable for long-term BP measurement, especially during nighttime. In this paper, we developed an armband wearable pulse transit time (PTT) system for 24-h cuff-less BP measurement and evaluated it in an unattended out-of-laboratory setting. Ten healthy young subjects participated in this ambulatory study, where PTT was measured at 30-min interval by this wearable system and the reference BP was measured by a standard oscillometric ambulatory BP monitor. Due to the misalignment of BP and PTT on their recording time caused by the different measurement principles of the two BP devices, a new estimation method has been proposed: transients in PTT were removed from the raw data by defined criteria, and then evenly interpolated, low-pass filtered, and resampled to synchronize at the time when BP was recorded. The results show that with the proposed method, the correlation between PTT and systolic BP (SBP) during nighttime with dynamic range of 21.8 ± 14.2 mmHg has improved from -0.50 ± 0.24 to -0.62 ± 0.20 , and the difference between the estimated and reference SBP has improved from 0.7 ± 10.7 to 2.8 ± 8.2 mmHg with root mean square error reduced from 10.7 to 8.7 mmHg. In addition, the correlation between a very low frequency component of SBP and PTT obtained from the proposed method during nighttime is -0.80 ± 0.10 and the difference is 2.4 ± 5.7 mmHg for a dynamic BP range of 13.5 ± 8.0 mmHg. It is therefore concluded from this study that the proposed wearable system has great potential to be used for overnight SBP monitoring, especially to measure the averaged SBP over a long period.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tbme.2014.2318779

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 177

Metadata

Authors
Zheng, Y.-L., Yan, B. P., Zhang, Y.-T., & Poon, C. C. Y.
Venue
IEEE Transactions on Biomedical Engineering
Published
2014-07
Volume
61
Issue
7
Pages
2179-2186
ISSN
  • 0018-9294 (ISSN-L)
  • 1558-2531
OpenAlex
W2028670183
Cited by
177
References
4
FWCI
6.95
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement. https://app.cochat.ai/papers/10.1109/tbme.2014.2318779
The paper
Zheng, Y.-L., Yan, B. P., Zhang, Y.-T., & Poon, C. C. Y. (2014). An Armband Wearable Device for Overnight and Cuff-Less Blood Pressure Measurement. IEEE Transactions on Biomedical Engineering. https://doi.org/10.1109/tbme.2014.2318779

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.