The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Fuzzy Cluster Analysis: A New Method to Predict Future Cardiac Events in Patients With Positive Stress Tests
Open accessAbstract
Several studies have shown that combining the change in the ST-segment with another exercise variable improves the predictive value of stress testing. However, no method has been able to combine many stress test variables with the ST-segment change simultaneously and help the clinician better predict future cardiac events. Fuzzy Cluster Analysis (FCA) was used to combine 5 stress test variables with ST-segment deviation to classify each of 232 positive outpatient stress tests as mildly, moderately, or severely abnormal. Cardiac events were recorded in these 3 patient groups up to 96 months (mean 65 months) after the stress tests. Coronary angiography was performed on 159 of these patients within 1 month of their stress tests. FCA better separated the 3 event-free survival curves than classifying the stress tests by three ST-segment (0.5-1.5 mm, 2-2.5 mm, > 3 mm) groups (p < 0.05). At 2 years, 90% of the FCA mild group were compared with 70% for the 0.5-1.5 mm group (p < 0.01). Moderate and severe tests by FCA separated patients with an intermediate from those with a poor prognosis while the 2-2.5 mm and 3 mm or more ST-segment curves did not (p < 0.05). FCA showed overall better correlation with coronary score (r = 0.71) than did the graded ST-segment groups (r = 0.48). FCA predicted both mild and high-grade (triple-vessel and left main) coronary disease better than ST-segment alone. Thus FCA better predicts future cardiac events in patients with positive stress tests than the ST-segment alone. This combined with its usefulness in predicting the extent of coronary disease provides the basis of a clinical strategy for managing patients with positive stress tests.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Prognostic Value of a Treadmill Exercise Score in Outpatients with Suspected Coronary Artery Disease
Mark, D. B., Shaw, L., Harrell, F. E., Hlatky, M. A., Lee, K. L., Bengtson, J. R., McCants, C. B., Califf, R. M., & Pryor, D. B. (1991) · New England Journal of Medicine · doi:10.1056/nejm199109193251204 · Cited by 837
Exercise Treadmill Score for Predicting Prognosis in Coronary Artery Disease
MARK, D. B., HLATKY, M. A., HARRELL, F. E., LEE, K. L., CALIFF, R. M., & PRYOR, D. B. (1987) · Annals of Internal Medicine · doi:10.7326/0003-4819-106-6-793 · Cited by 671
Ellestad, M. H., & Wan, M. K. (1975) · Circulation · doi:10.1161/01.cir.51.2.363 · Cited by 459 · cited 1×
“S2 40 40-35 35-30 30-25 25-20 20-15 15-10 10-5 5-(5) (5-15) >(15) (mmHg)”
Bayesian Analysis of Electrocardiographic Exercise Stress Testing
Rifkin, R. D., & Hood, W. B. (1977) · New England Journal of Medicine · doi:10.1056/nejm197709292971301 · Cited by 282
Exercise-induced hypotension in a male population. Criteria, causes, and prognosis.
Dubach, P., Froelicher, V. F., Klein, J., Oakes, D., Grover‐McKay, M., & Friis, R. (1988) · Circulation · doi:10.1161/01.cir.78.6.1380 · Cited by 134
Significance of chest pain during treadmill exercise: Correlation with coronary events
Cole, J. P., & Ellestad, M. (1978) · The American Journal of Cardiology · doi:10.1016/0002-9149(78)90161-3 · Cited by 118
Clinical and angiographic correlates and prognostic significance of the coronary extent score
Moise, A., Clement, B., & Saltiel, J. (1988) · The American Journal of Cardiology · doi:10.1016/0002-9149(88)91165-4 · Cited by 38
Peters, R. M., Shanies, S. A., & Peters, J. C. (1995) · The American Journal of Cardiology · doi:10.1016/s0002-9149(99)80190-8 · Cited by 19
Self-citation
Cited by
Image denoising by sparse 3-D transform-domain collaborative filtering
Dabov, K., Foi, A., Katkovnik, V., & Egiazarian, K. (2007) · IEEE Transactions on Image Processing · doi:10.1109/tip.2007.901238 · Cited by 9,283
Using Bayesian Networks to Analyze Expression Data
Friedman, N., Linial, M., Nachman, I., & Pe'er, D. (2000) · Journal of Computational Biology · doi:10.1089/106652700750050961 · Cited by 3,266
Is There a Need for Fuzzy Logic?
Zadeh, L. A. (2008) · Information Sciences · doi:10.1016/j.ins.2008.02.012 · Cited by 1,352
A survey on nature inspired metaheuristic algorithms for partitional clustering
Nanda, S. J., & Panda, G. (2014) · Swarm and Evolutionary Computation · doi:10.1016/j.swevo.2013.11.003 · Cited by 574
ECG beat recognition using fuzzy hybrid neural network
Osowski, S., & Linh, T. H. (2001) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.959322 · Cited by 518
Metadata
- Authors
- Peters, R. M., Shanies, S. A., & Peters, J. C.
- Venue
- Japanese Circulation Journal
- Publisher
- Japanese Circulation Society
- Published
- 1998
- Volume
- 62
- Issue
- 10
- Pages
- 750-754
- ISSN
- 0047-1828 (ISSN-L)
- 1347-4839
- OpenAlex
- W1941358455
- Cited by
- 811
- References
- 8
- FWCI
- 9.09
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.