Internal quality control: planning and implementation strategies
The DOI matches its Crossref record; 24 of the 24 references it cites were found in a registry or an index.
Abstract
The first essential in setting up internal quality control (IQC) of a test procedure in the clinical laboratory is to select the proper IQC procedure to implement, i.e. choosing the statistical criteria or control rules, and the number of control measurements, according to the quality required for the test and the observed performance of the method. Then the right IQC procedure must be properly implemented. This review focuses on strategies for planning and implementing IQC procedures in order to improve the quality of the IQC. A quantitative planning process is described that can be implemented with graphical tools such as power function or critical-error graphs and charts of operating specifications. Finally, a total QC strategy is formulated to minimize cost and maximize quality. A general strategy for IQC implementation is recommended that employs a three-stage design in which the first stage provides high error detection, the second stage low false rejection and the third stage prescribes the length of the analytical run, making use of an algorithm involving the average of normal patients' data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Economic Control of Quality of Manufactured Product.
Hotelling, H., & Shewhart, W. A. (1932) · Journal of the American Statistical Association · doi:10.2307/2277676 · Cited by 3,070
Current databases on biological variation: pros, cons and progress
C. Ricós, V. A. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185229 · Cited by 987
A multi-rule Shewhart chart for quality control in clinical chemistry.
Westgard, J. O., Barry, P. L., Hunt, M. R., & Groth, T. (1981) · Clinical Chemistry · doi:10.1093/clinchem/27.3.493 · Cited by 831
Self-citationMistakes in a stat laboratory: types and frequency
Plebani, M., & Carraro, P. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.8.1348 · Cited by 572
The use of Control Charts in the Clinical Laboratory*
Levey, S., & Jennings, E. R. (1950) · American Journal of Clinical Pathology · doi:10.1093/ajcp/20.11_ts.1059 · Cited by 359
Criteria for judging precision and accuracy in method development and evaluation
Westgard, J. O., Carey, R. N., & Wold, S. (1974) · Clinical Chemistry · doi:10.1093/clinchem/20.7.825 · Cited by 236
Self-citationIntroduction: Strategies to set global quality specifications in laboratory medicine
C. G. Fraser, A. K. (1999) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365519950185184 · Cited by 172
Westgard, J. O., Groth, T., Aronsson, T., Falk, H., & de Verdier, C. H. (1977) · Clinical Chemistry · doi:10.1093/clinchem/23.10.1857 · Cited by 152
Self-citationPower functions for statistical control rules.
Westgard, J. O., & Groth, T. (1979) · Clinical Chemistry · doi:10.1093/clinchem/25.6.863 · Cited by 144
Self-citationCombined Shewhart-Cusum control chart for improved quality control in clinical chemistry
Westgard, J. O., Groth, T., Aronsson, T., & de Verdier, C. H. (1977) · Clinical Chemistry · doi:10.1093/clinchem/23.10.1881 · Cited by 138
Self-citationThe “Average of Normals” Method of Quality Control
Hoffmann, R. G., & Waid, M. E. (1965) · American Journal of Clinical Pathology · doi:10.1093/ajcp/43.2.134 · Cited by 127
Fraser, C. G., Petersen, P. H., Ricós, C., & Haeckel, R. (1992) · PubMed · Cited by 125
Assessment of “Average of Normals” Quality Control Procedures and Guidelines for Implementation
Cembrowski, G. S., Chandler, E. P., & Westgard, J. O. (1984) · American Journal of Clinical Pathology · doi:10.1093/ajcp/81.4.492 · Cited by 97
Self-citationWestgard, J. O. (1992) · Clinical Chemistry · doi:10.1093/clinchem/38.7.1226 · Cited by 85
Self-citationRunning of Standards in Clinical Chemistry and the Use of the Control Chart
Henry, R. J., & SEGALOVE, M. (1952) · Journal of Clinical Pathology · doi:10.1136/jcp.5.4.305 · Cited by 65
STRATEGIES TO SET GLOBAL ANALYTICAL QUALITY SPECIFICATION, IN LABORATORY MEDICINE
Petersen, P. H., Fraser, C. G., Kallner, A., & Kenny, D. (1999) · Cited by 64
Koch, D. D., Oryall, J. J., Quam, E. F., Feldbruegge, D. H., Dowd, D., Barry, P. L., & Westgard, J. O. (1990) · Clinical Chemistry · doi:10.1093/clinchem/36.2.230 · Cited by 60
Self-citationKlee, G. G. (1993) · Clinical Chemistry · doi:10.1093/clinchem/39.7.1514 · Cited by 40
Westgard, J. O., Smith, F. A., Mountain, P. J., & Boss, S. B. (1996) · Clinical Chemistry · doi:10.1093/clinchem/42.10.1683 · Cited by 40
Self-citationPoints of care in using statistics in method comparison studies.
Westgard, J. O. (1998) · PubMed · Cited by 30
Self-citationWhat is the quality of quality control procedures?
de Verdier, C., Groth, T., & Westgard, J. O. (1981) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365518109092008 · Cited by 27
Self-citationPrinciples for developing improved quality control procedures.
Jo, W., Groth, T., & VERDIER, C. H. D. (1984) · PubMed · Cited by 26
Groth, T., Falk, H., & Westgard, J. O. (1981) · Computer Programs in Biomedicine · doi:10.1016/0010-468x(81)90085-4 · Cited by 24
Self-citationAdvantages of CUSUM techniques for quality control in clinical chemistry
Rowlands, R. J., Wilson, D. W., Nix, A. B. J., et al. (1980) · Clinica Chimica Acta · doi:10.1016/0009-8981(80)90346-0 · Cited by 12
Cited by
Quality control review: implementing a scientifically based quality control system
Westgard, J. O., & Westgard, S. A. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215597248 · Cited by 109
“A recommendation for planning SQC procedures was a major focus of the 2003 QC review.(1) The key information that is needed is the probability of rejecting an analytical run as function of the size of the errors occurring in a run.”
BackgroundSelf-citationÇubukçu, H. C. (2021) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2021-0199 · Cited by 13
“The QC rules corresponding to the Ped of ≥ 0.9 were regarded as acceptable for an intended degree of systematic error [2].”
BackgroundMethodInfluentialQuality requirements for quantitative clinical chemistry proteomics
(2014) · Translational Proteomics · doi:10.1016/j.trprot.2013.10.001 · Cited by 11
Yim, J., Rim, J. H., Lim, Y. K., Cho, Y., Park, Y., Kim, S., & Yun, Y.-M. (2023) · Laboratory Medicine Online · doi:10.47429/lmo.2023.13.4.255 · Cited by 1
Metadata
- Authors
- Westgard, J. O.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2003-11-01
- Volume
- 40
- Issue
- 6
- Pages
- 593-611
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W1970075788
- Cited by
- 172
- References
- 24
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.