Self-monitoring of blood glucose in diabetes: is it worth it?
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
Self-monitoring of blood glucose (SMBG) is advocated as a valuable aid in the management of diabetes. The volume and cost of monitoring continues to increase. SMBG has a number of theoretical advantages/disadvantages which might impact on treatment, outcome and wellbeing. Investigating and quantifying the effect of self-monitoring in a condition where self-management plays a central role poses major methodological difficulties because of the need to minimize confounding factors. Despite the absence of definitive evidence, some situations where monitoring is generally accepted to be beneficial include patients on insulin, during pregnancy, in patients with hypoglycaemia unawareness and while driving. An area of controversy is the role of monitoring in non-insulin-requiring type-2 diabetes where observational and controlled studies give conflicting results. The available evidence does not support the general use of monitoring by all patients with type-2 diabetes, although further research is needed to identify specific subgroups of patients or specific situations where monitoring might be useful. The best use of SMBG in patients with type-2 diabetes might be for those receiving insulin and those on sulphonylurea drugs. The impact of monitoring on patient wellbeing must also be considered, with some studies suggesting adverse psychological effects. Given the large increase in the prevalence of type-2 diabetes, it will be important to define the role of SMBG so that resources can be used appropriately. Presently, the widespread use of SMBG (particularly in type-2 diabetes patients) is a good example of self-monitoring that was adopted in advance of robust evidence of its clinical efficacy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Standards of Medical Care in Diabetes—2007
American Diabetes Association (2007) · Diabetes Care · doi:10.2337/dc07-s004 · Cited by 1,190
The Hawthorne effect: A reconsideration of the methodological artifact.
Adair, J. G. (1984) · Journal of Applied Psychology · doi:10.1037/0021-9010.69.2.334 · Cited by 1,095
Hypoglycaemia in Type 2 diabetes
Amiel, S. A., Dixon, T., Mann, R., & Jameson, K. (2008) · Diabetic Medicine · doi:10.1111/j.1464-5491.2007.02341.x · Cited by 472
Global guideline for type 2 diabetes: recommendations for standard, comprehensive, and minimal care
IDF Clinical Guidelines Task Force (2006) · Diabetic Medicine · doi:10.1111/j.1464-5491.2006.01918.x · Cited by 433
Farmer, A., Wade, A., Goyder, E., Yudkin, P., French, D., Craven, A., Holman, R., Kinmonth, A.-L., & Neil, A. (2007) · BMJ · doi:10.1136/bmj.39247.447431.be · Cited by 407
Self-Monitoring of Blood Glucose in Patients With Type 2 Diabetes Who Are Not Using Insulin
Welschen, L. M. C., Bloemendal, E., Nijpels, G., Dekker, J. M., Heine, R. J., Stalman, W. A. B., & Bouter, L. M. (2005) · Diabetes Care · doi:10.2337/diacare.28.6.1510 · Cited by 374
O’Kane, M. J., Bunting, B., Copeland, M., & Coates, V. E. (2008) · BMJ · doi:10.1136/bmj.39534.571644.be · Cited by 326
Self-citationMeal-Related Structured Self-Monitoring of Blood Glucose
Schwedes, U., Siebolds, M., Mertes, G., & For the SMBG Study Group (2002) · Diabetes Care · doi:10.2337/diacare.25.11.1928 · Cited by 300
Guerci, B., Drouin, P., Grangé, V, Bougnères, P., Fontaine, P., Kerlan, V, Passa, P., Thivolet, C., Vialettes, B., & Charbonnel, B. (2003) · Diabetes & Metabolism · doi:10.1016/s1262-3636(07)70073-3 · Cited by 287
Martin, S., Schneider, B., Heinemann, L., Lodwig, V., Kurth, H.-J., Kolb, H., Scherbaum, W. A., & for the ROSSO Study Group (2006) · Diabetologia · doi:10.1007/s00125-005-0083-5 · Cited by 284
Cited by
Glucose Biosensors: An Overview of Use in Clinical Practice
Yoo, E.-H., & Lee, S.-Y. (2010) · Sensors · doi:10.3390/s100504558 · Cited by 1,137
“Self-monitoring of blood glucose (SMBG) has been established as a valuable tool for the management of diabetes [6-12].”
MethodSelf-monitoring of blood glucose in patients with type 2 diabetes mellitus who are not using insulin
Malanda, U. L., Welschen, L. M., Riphagen, I. I., Dekker, J. M., Nijpels, G., & Bot, S. D. (2012) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd005060.pub3 · Cited by 358
Self-monitoring of blood glucose in type 2 diabetes: systematic review
Clar, C., Barnard, K., Cummins, E., Royle, P., & Waugh, N. (2010) · Health Technology Assessment · doi:10.3310/hta14120 · Cited by 274
Frequency of self-monitoring blood glucose and attainment of HbA1c target values
Elgart, J. F., González, L., Prestes, M., Rucci, E., & Gagliardino, J. J. (2016) · Acta Diabetologica · doi:10.1007/s00592-015-0745-9 · Cited by 51
“However, whereas the beneficial effect of SMBG performance on glycemic control in patients with either T1DM or T2DM treated with insulin is well recognized, this effect on patients with T2DM not treated with insulin remains controversial [6–11].”
Background
Metadata
- Authors
- O'Kane, M. J., & Pickup, J.
- Venue
- Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
- Publisher
- SAGE Publications
- Published
- 2009-05-19
- Volume
- 46
- Issue
- 4
- Pages
- 273-282
- ISSN
- 0004-5632 (ISSN-L)
- 1758-1001
- OpenAlex
- W1991259712
- Cited by
- 39
- References
- 22
- FWCI
- 1.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Self-monitoring of blood glucose in diabetes: is it worth it? https://app.cochat.ai/papers/10.1258/acb.2009.009011
- The paper
- O'Kane, M. J., & Pickup, J. (2009). Self-monitoring of blood glucose in diabetes: is it worth it? Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1258/acb.2009.009011
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.