CoChat

A simplified liquid chromatography tandem mass spectrometry assay, using on-line solid-phase extraction, for the quantitation of cortisol in saliva and comparison with a routine DELFIA method

Owen, L J, Haslam, S, Adaway, J E, Wood, P, Glenn, C, Keevil, B G · 2010 · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Cited by 26

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

Background: We have developed a liquid chromatography tandem mass spectrometry (LC-MS/MS) method for measuring salivary cortisol, which requires only 200 μL sample and no extraction. Methods: Sample (200 μL) and 25 μL internal standard were added directly to a 96-deep-well plate. Of this, 50 μL was loaded onto a guard cartridge, the cartridge was then washed and the eluate was diverted to waste. The compounds were eluted from the guard cartridge onto the C18 analytical column. Cortisol and deuterated cortisol were monitored using transitions m/z 363.2 > 121.1 and 365.1 > 122.2, respectively. Results: The method had a lower limit of quantitation of 2 nmol/L. Intra-assay and inter-assay imprecision were better than 9.5%. Comparison with an established dissociation enhanced lanthanide fluorescent immunoassay (DELFIA) gave good agreement for the majority of samples; LC-MS/MS = 1.0065 × DELFIA − 3.7 ( n = 130). The reference range was determined to be 5.8–45.7 nmol/L at 08:00 h and <6.4 nmol/L at 23:00 h ( n = 44). Conclusions: We have developed a simple, robust assay to measure salivary cortisol using on-line solid-phase extraction to reduce sample clean-up requirements.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1258/acb.2009.009053

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 26

Metadata

Authors
Owen, L. J., Haslam, S., Adaway, J. E., Wood, P., Glenn, C., & Keevil, B. G.
Venue
Annals of Clinical Biochemistry: International Journal of Laboratory Medicine
Published
2010-02-11
Volume
47
Issue
2
Pages
131-136
ISSN
  • 0004-5632 (ISSN-L)
  • 1758-1001
OpenAlex
W2132567408
Cited by
26
References
4
FWCI
1.40
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A simplified liquid chromatography tandem mass spectrometry assay, using on-line solid-phase extraction, for the quantitation of cortisol in saliva and comparison with a routine DELFIA method. https://app.cochat.ai/papers/10.1258/acb.2009.009053
The paper
Owen, L. J., Haslam, S., Adaway, J. E., Wood, P., Glenn, C., & Keevil, B. G. (2010). A simplified liquid chromatography tandem mass spectrometry assay, using on-line solid-phase extraction, for the quantitation of cortisol in saliva and comparison with a routine DELFIA method. Annals of Clinical Biochemistry: International Journal of Laboratory Medicine. https://doi.org/10.1258/acb.2009.009053

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.