The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Medical imaging by NMR
Abstract
Application of the new nuclear magnetic resonance (NMR) method of fast scan proton imaging is described. Cross sectional proton scans of a human finger in vivo are measured and reveal considerable anatomical detail, particularly of the soft tissue regions. Imaging of tumour tissue is also briefly discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Image Formation by Induced Local Interactions: Examples Employing Nuclear Magnetic Resonance
LAUTERBUR, P. C. (1973) · Nature · doi:10.1038/242190a0 · Cited by 3,611
Tumor Detection by Nuclear Magnetic Resonance
Damadian, R. (1971) · Science · doi:10.1126/science.171.3976.1151 · Cited by 1,466
Mansfield, P., & Grannell, P. K. (1973) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/6/22/007 · Cited by 551
Self-citationFunctional and Surgical Anatomy of the Hand
Kaplan, E. B. (1966) · The American Journal of the Medical Sciences · doi:10.1097/00000441-196603000-00030 · Cited by 315
Image formation in NMR by a selective irradiative process
Garroway, A. N., Grannell, P. K., & Mansfield, P. (1974) · Journal of Physics C: Solid State Physics · doi:10.1088/0022-3719/7/24/006 · Cited by 271
Self-citation"Diffraction" and microscopy in solids and liquids by NMR
Mansfield, P., & Grannell, P. K. (1975) · Physical Review B · doi:10.1103/physrevb.12.3618 · Cited by 266
Self-citation
Cited by
Radiation oncology: a century of achievements
Bernier, J., Hall, E. J., & Giaccia, A. (2004) · Nature Reviews Cancer · doi:10.1038/nrc1451 · Cited by 628
Radiographic thin-section image of the human wrist by nuclear magnetic resonance
HINSHAW, W. S., BOTTOMLEY, P. A., & HOLLAND, G. N. (1977) · Nature · doi:10.1038/270722a0 · Cited by 252
Clinical indications for digital imaging in dento‐alveolar trauma. Part 1: traumatic injuries
Cohenca, N., Simon, J. H., Roges, R., Morag, Y., & Malfaz, J. M. (2007) · Dental Traumatology · doi:10.1111/j.1600-9657.2006.00509.x · Cited by 209
Neuroimaging for drug addiction and related behaviors
Parvaz, M. A., Alia-Klein, N., Woicik, P. A., Volkow, N. D., & Goldstein, R. Z. (2011) · Reviews in the Neurosciences · doi:10.1515/rns.2011.055 · Cited by 151
Metadata
- Authors
- Mansfield, P., & Maudsley, A. A.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1977-03
- Volume
- 50
- Issue
- 591
- Pages
- 188-194
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2105440094
- Cited by
- 364
- References
- 6
- FWCI
- 16.30
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Medical imaging by NMR. https://app.cochat.ai/papers/10.1259/0007-1285-50-591-188
- The paper
- Mansfield, P., & Maudsley, A. A. (1977). Medical imaging by NMR. The British Journal of Radiology. https://doi.org/10.1259/0007-1285-50-591-188
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.