Comparative performance in vitro and in vivo of Lunar DPX and Hologic QDR-1000 dual energy X-ray absorptiometers
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The measured absolute bone mineral density values of spine and femur and their precision were compared on two dual energy X-ray absorptiometers, the Lunar DPX and the Hologic QDR-1000. There were systematic differences between the two systems, the Lunar DPX always giving a higher bone density value. The ratio of the mean Lunar DPX/Hologic QDR-1000 bone density measurements obtained in vivo was 1.13 g/cm2 for spine (L2–L4) and 1.20–1.43 g/cm2 for femur measurements. For both systems, short- and long-term precision (coefficient of variation) was below 0.5% for spine in vitro measurements and below 1.5% for neck of femur in vitro measurements. Precision of in vivo measurements was less good, especially for femur measurements. The coefficient of variation of spine measurements was dependent on bone density and deteriorated with decreased bone mineral density and increased body thickness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Cited by
Dual-energy X-ray absorptiometry and body composition
Laskey, M. A. (1996) · Nutrition · doi:10.1016/0899-9007(95)00017-8 · Cited by 407
Self-citationTea drinking and bone mineral density in older women
Hegarty, V. M., May, H. M., & Khaw, K.-T. (2000) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/71.4.1003 · Cited by 294
Diagnosis of Osteoporosis in Men, Premenopausal Women, and Children
THEWRITINGGROUPFORTHEISCDPO (2004) · Journal of Clinical Densitometry · doi:10.1385/jcd:7:1:17 · Cited by 273
Prynne, C. J., Mishra, G. D., O’Connell, M. A., Muniz, G., Laskey, M. A., Yan, L., Prentice, A., & Ginty, F. (2006) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/83.6.1420 · Cited by 267
Self-citationKalender, W. A., Felsenberg, D., Genant, H. K., Fischer, M., Dequeker, J., & Reeve, J. (1995) · European Journal of Radiology · doi:10.1016/0720-048x(95)00631-y · Cited by 263
Metadata
- Authors
- Laskey, M. A., Flaxman, M. E., Barber, R. W., Trafford, S., Hayball, M. P., Lyttle, K. D., Crisp, A. J., & Compston, J. E.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1991-11-11
- Volume
- 64
- Issue
- 767
- Pages
- 1023-1029
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2000963252
- Cited by
- 114
- References
- 1
- FWCI
- 9.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Comparative performance in vitro and in vivo of Lunar DPX and Hologic QDR-1000 dual energy X-ray absorptiometers. https://app.cochat.ai/papers/10.1259/0007-1285-64-767-1023
- The paper
- Laskey, M. A., Flaxman, M. E., Barber, R. W., Trafford, S., Hayball, M. P., Lyttle, K. D., Crisp, A. J., & Compston, J. E. (1991). Comparative performance in vitro and in vivo of Lunar DPX and Hologic QDR-1000 dual energy X-ray absorptiometers. The British Journal of Radiology. https://doi.org/10.1259/0007-1285-64-767-1023
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.