Abstract

Measurements of whole-body bone mineral made by Hologic, Lunar and Norland dual-energy X-ray absorptiometers have been compared. It was found that in each case the results were changed by new software protocols introduced by the manufacturers during the course of the study. With a moderately anthropomorphic model, the later software corrected some anomalies of regional bone mineral content (BMC) observed earlier. There was some slight dependence of total BMC on thickness and fat proportion and up to 15% difference between instruments. Measurements on volunteers showed good precision, but there were differences between instruments made by different manufacturers. There were high correlations, but the slopes of regression lines suggested differences of calibration of up to 8%; the standard errors of the estimates were 110 to 190 g, with maximum deviations from regression of 17%. There were regional disparities in BMC, particularly in the trunk, which arise (in part at least) from the imposition of a higher bone threshold by Hologic. From the pattern of results it was concluded that different assumptions were made by the manufacturers, particularly concerning the fat distribution model, which preclude the interchangeability of results from different instruments.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1259/0007-1285-67-804-1210

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 133

Metadata

Authors
Tothill, P., Avenell, A., & Reid, D. M.
Venue
The British Journal of Radiology
Published
1994-12-01
Volume
67
Issue
804
Pages
1210-1217
ISSN
  • 0007-1285 (ISSN-L)
  • 1748-880X
OpenAlex
W2104807075
Cited by
133
References
0
FWCI
6.11
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Precision and accuracy of measurements of whole-body bone mineral: comparisons between Hologic, Lunar and Norland dual-energy X-ray absorptiometers. https://app.cochat.ai/papers/10.1259/0007-1285-67-804-1210
The paper
Tothill, P., Avenell, A., & Reid, D. M. (1994). Precision and accuracy of measurements of whole-body bone mineral: comparisons between Hologic, Lunar and Norland dual-energy X-ray absorptiometers. The British Journal of Radiology. https://doi.org/10.1259/0007-1285-67-804-1210

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.