Precision and accuracy of measurements of whole-body bone mineral: comparisons between Hologic, Lunar and Norland dual-energy X-ray absorptiometers
The DOI matches its Crossref record.
Abstract
Measurements of whole-body bone mineral made by Hologic, Lunar and Norland dual-energy X-ray absorptiometers have been compared. It was found that in each case the results were changed by new software protocols introduced by the manufacturers during the course of the study. With a moderately anthropomorphic model, the later software corrected some anomalies of regional bone mineral content (BMC) observed earlier. There was some slight dependence of total BMC on thickness and fat proportion and up to 15% difference between instruments. Measurements on volunteers showed good precision, but there were differences between instruments made by different manufacturers. There were high correlations, but the slopes of regression lines suggested differences of calibration of up to 8%; the standard errors of the estimates were 110 to 190 g, with maximum deviations from regression of 17%. There were regional disparities in BMC, particularly in the trunk, which arise (in part at least) from the imposition of a higher bone threshold by Hologic. From the pattern of results it was concluded that different assumptions were made by the manufacturers, particularly concerning the fat distribution model, which preclude the interchangeability of results from different instruments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Human Body Composition: In Vivo Methods
Ellis, K. J. (2000) · Physiological Reviews · doi:10.1152/physrev.2000.80.2.649 · Cited by 825
Gordon, C. M., Bachrach, L. K., Carpenter, T. O., Crabtree, N., El-Hajj Fuleihan, G., Kutilek, S., Lorenc, R. S., Tosi, L. L., Ward, K. A., Ward, L. M., et al. (2008) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2007.12.005 · Cited by 720
Body-composition assessment via air-displacement plethysmography in adults and children: a review
Fields, D. A., Goran, M. I., & McCrory, M. A. (2002) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/75.3.453 · Cited by 638
Deurenberg-Yap, M., Schmidt, G., van Staveren, W., & Deurenberg, P. (2000) · International Journal of Obesity · doi:10.1038/sj.ijo.0801353 · Cited by 580
Crabtree, N. J., Arabi, A., Bachrach, L. K., Fewtrell, M., El-Hajj Fuleihan, G., Kecskemethy, H. H., Jaworski, M., & Gordon, C. M. (2014) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2014.01.003 · Cited by 552
Johnstone, A. M., Murison, S. D., Duncan, J. S., Rance, K. A., & Speakman, J. R. (2005) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/82.5.941 · Cited by 514
Dual-energy X-ray absorptiometry and body composition
Laskey, M. A. (1996) · Nutrition · doi:10.1016/0899-9007(95)00017-8 · Cited by 407
Speakman, J. R., Rance, K. A., & Johnstone, A. M. (2008) · Obesity · doi:10.1038/oby.2008.318 · Cited by 325
In vivo validation of whole body composition estimates from dual-energy X-ray absorptiometry
Prior, B. M., Cureton, K. J., Modlesky, C. M., Evans, E. M., Sloniger, M. A., Saunders, M., & Lewis, R. D. (1997) · Journal of Applied Physiology · doi:10.1152/jappl.1997.83.2.623 · Cited by 317
Deurenberg‐Yap, M., Chew, S. K., & Deurenberg, P. (2002) · Obesity Reviews · doi:10.1046/j.1467-789x.2002.00069.x · Cited by 318
Body composition of a young, multiethnic female population
Ellis, K., Abrams, S., & Wong, W. (1997) · The American Journal of Clinical Nutrition · doi:10.1093/ajcn/65.3.724 · Cited by 252
“instrument provides the most accurate measure of true bone examined in this study and is supported by observed changes in mineral mass ( 26-28 ).”
MethodHangartner, T. N., Warner, S., Braillon, P., Jankowski, L., & Shepherd, J. (2013) · Journal of Clinical Densitometry · doi:10.1016/j.jocd.2013.08.007 · Cited by 242
“(2,11e13), between different models of the same manufacturer (12,14e16), the same densitometer with different analysis software (5,10), and even using different scan modes and geometries on the same device (17).”
BackgroundInfluentialDevelopment of methods for body composition studies
Mattsson, S., & Thomas, B. J. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/13/r13 · Cited by 193
“Differences of 10% in fat mass (FM), 6% in lean tissue mass (Kistorp and Svendsen 1997) and 2.6–6.3% in % body fat (Tothill et al 1994) are typical of the differences reported.”
BackgroundInfluentialBolotin, H. H., & Sievänen, H. (2001) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2001.16.5.799 · Cited by 185
Measurement Precision of Body Composition Variables Using the Lunar DPX-L Densitometer
Kiebzak, G. M., Leamy, L. J., Pierson, L. M., Nord, R. H., & Zhang, Z. Y. (2000) · Journal of Clinical Densitometry · doi:10.1385/jcd:3:1:035 · Cited by 182
Genton, L., Hans, D., Kyle, U. G., & Pichard, C. (2002) · Nutrition · doi:10.1016/s0899-9007(01)00700-6 · Cited by 175
Pediatric body composition analysis with dual-energy X-ray absorptiometry.
Helba, M., & Binkovitz, L. A. (2009) · Pediatric Radiology · doi:10.1007/s00247-009-1247-0 · Cited by 127
“These assumptions, many of which are proprietary, differ among DXA manufacturers [22, 23] and the software used for analysis [24], and thus comparison of BCA results require careful attention to equipment and software differences.”
BackgroundEllis, K. J., & Shypailo, R. J. (1998) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1998.13.10.1613 · Cited by 108
Tothill, P., Hannan, W. J., & Wilkinson, S. (2001) · The British Journal of Radiology · doi:10.1259/bjr.74.878.740166 · Cited by 71
Self-citationSilva, A. M., Fields, D. A., & Sardinha, L. B. (2013) · Journal of Obesity · doi:10.1155/2013/148696 · Cited by 52
Gillette-Guyonnet, S. (2003) · Mechanisms of Ageing and Development · doi:10.1016/s0047-6374(02)00199-9 · Cited by 32
Impact of bone mineral estimates on percent fat estimates from a four-component model
MODLESKY, C. M., EVANS, E. M., MILLARD-STAFFORD, M. L., COLLINS, M. A., LEWIS, R. D., & CURETON, K. J. (1999) · Medicine & Science in Sports & Exercise · doi:10.1097/00005768-199912000-00026 · Cited by 24
Metadata
- Authors
- Tothill, P., Avenell, A., & Reid, D. M.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1994-12-01
- Volume
- 67
- Issue
- 804
- Pages
- 1210-1217
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2104807075
- Cited by
- 133
- References
- 0
- FWCI
- 6.11
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›