Online daily adaptive proton therapy
Open accessThe DOI matches its Crossref record; 54 of the 54 references it cites were found in a registry or an index.
Abstract
It is recognized that the use of a single plan calculated on an image acquired some time before the treatment is generally insufficient to accurately represent the daily dose to the target and to the organs at risk. This is particularly true for protons, due to the physical finite range. Although this characteristic enables the generation of steep dose gradients, which is essential for highly conformal radiotherapy, it also tightens the dependency of the delivered dose to the range accuracy. In particular, the use of an outdated patient anatomy is one of the most significant sources of range inaccuracy, thus affecting the quality of the planned dose distribution. A plan should be ideally adapted as soon as anatomical variations occur, ideally online. In this review, we describe in detail the different steps of the adaptive workflow and discuss the challenges and corresponding state-of-the art developments in particular for an online adaptive strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Statistical shape models for 3D medical image segmentation: A review
Heimann, T., & Meinzer, H.-P. (2009) · Medical Image Analysis · doi:10.1016/j.media.2009.05.004 · Cited by 1,417
Brock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
Yan, D., Vicini, F., Wong, J., & Martinez, A. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/1/008 · Cited by 761
Deep learning in medical imaging and radiation therapy
Sahiner, B., Pezeshk, A., Hadjiiski, L. M., Wang, X., Drukker, K., Cha, K. H., Summers, R. M., & Giger, M. L. (2019) · Medical Physics · doi:10.1002/mp.13264 · Cited by 740
In vivoproton range verification: a review
Knopf, A. C., & Lomax, A. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/15/r131 · Cited by 620
Self-citationRaaymakers, B. W., Jürgenliemk-Schulz, I. M., Bol, G. H., Glitzner, M., Kotte, A. N. T. J., van Asselen, B., de Boer, J. C. J., Bluemink, J. J., Hackett, S. L., Moerland, M. A., et al. (2017) · Physics in Medicine & Biology · doi:10.1088/1361-6560/aa9517 · Cited by 541
Vision 20/20: Perspectives on automated image segmentation for radiotherapy
Sharp, G., Fritscher, K. D., Pekar, V., Peroni, M., Shusharina, N., Veeraraghavan, H., & Yang, J. (2014) · Medical Physics · doi:10.1118/1.4871620 · Cited by 375
Clinical evaluation of atlas and deep learning based automatic contouring for lung cancer
Lustberg, T., van Soest, J., Gooding, M., Peressutti, D., Aljabar, P., van der Stoep, J., van Elmpt, W., & Dekker, A. (2018) · Radiotherapy and Oncology · doi:10.1016/j.radonc.2017.11.012 · Cited by 368
Rudra, S., Jiang, N., Rosenberg, S. A., Olsen, J. R., Roach, M. C., Wan, L., Portelance, L., Mellon, E. A., Bruynzeel, A., Lagerwaard, F., et al. (2019) · Cancer Medicine · doi:10.1002/cam4.2100 · Cited by 350
A planning quality evaluation tool for prostate adaptive IMRT based on machine learning
Zhu, X., Ge, Y., Li, T., Thongphiew, D., Yin, F., & Wu, Q. J. (2011) · Medical Physics · doi:10.1118/1.3539749 · Cited by 324
Cited by
Roadmap: proton therapy physics and biology
Paganetti, H., Beltran, C., Both, S., Dong, L., Flanz, J., Furutani, K., Grassberger, C., Grosshans, D. R., Knopf, A.-C., Langendijk, J. A., et al. (2021) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abcd16 · Cited by 175
Metadata
- Authors
- Albertini, F., Matter, M., Nenoff, L., Zhang, Y., & Lomax, A.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2019-11-11
- Volume
- 93
- Issue
- 1107
- Pages
- 20190594-20190594
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2981674662
- Cited by
- 165
- References
- 54
- FWCI
- 8.90
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Online daily adaptive proton therapy. https://app.cochat.ai/papers/10.1259/bjr.20190594
- The paper
- Albertini, F., Matter, M., Nenoff, L., Zhang, Y., & Lomax, A. (2020). Online daily adaptive proton therapy. The British Journal of Radiology. https://doi.org/10.1259/bjr.20190594
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.