Radiology's Achilles' heel: error and variation in the interpretation of the Röntgen image.
The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Abstract
The performance of the human eye and brain has failed to keep pace with the enormous technical progress in the first full century of radiology. Errors and variations in interpretation now represent the weakest aspect of clinical imaging. Those interpretations which differ from the consensus view of a panel of "experts" may be regarded as errors; where experts fail to achieve consensus, differing reports are regarded as "observer variation". Errors arise from poor technique, failures of perception, lack of knowledge and misjudgments. Observer variation is substantial and should be taken into account when different diagnostic methods are compared; in many cases the difference between observers outweighs the difference between techniques. Strategies for reducing error include attention to viewing conditions, training of the observers, availability of previous films and relevant clinical data, dual or multiple reporting, standardization of terminology and report format, and assistance from computers. Digital acquisition and display will probably not affect observer variation but the performance of radiologists, as measured by receiver operating characteristic (ROC) analysis, may be improved by computer-directed search for specific image features. Other current developments show that where image features can be comprehensively described, computer analysis can replace the perception function of the observer, whilst the function of interpretation can in some cases be performed better by artificial neural networks. However, computer-assisted diagnosis is still in its infancy and complete replacement of the human observer is as yet a remote possibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Measurement of Observer Agreement for Categorical Data
Landis, J. R., & Koch, G. G. (1977) · Biometrics · doi:10.2307/2529310 · Cited by 81,148
A Coefficient of Agreement for Nominal Scales
Cohen, J. (1960) · Educational and Psychological Measurement · doi:10.1177/001316446002000104 · Cited by 42,398
Data Reduction and Error Analysis for the Physical Sciences
Bevington, P. R., Robinson, D. K., Blair, J. M., Mallinckrodt, A. J., & McKay, S. (1993) · Computers in Physics · doi:10.1063/1.4823194 · Cited by 14,824
Measuring nominal scale agreement among many raters.
Fleiss, J. L. (1971) · Psychological Bulletin · doi:10.1037/h0031619 · Cited by 8,733
ROC Methodology in Radiologic Imaging
METZ, C. E. (1986) · Investigative Radiology · doi:10.1097/00004424-198609000-00009 · Cited by 1,642
ROC Analysis Applied to the Evaluation of Medical Imaging Techniques
SWETS, J. A. (1979) · Investigative Radiology · doi:10.1097/00004424-197903000-00002 · Cited by 699
Sidor, M. L., Zuckerman, J. D., Lyon, T., Koval, K., Cuomo, F., & Schoenberg, N. (1993) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199312000-00002 · Cited by 455
Visual Scanning, Pattern Recognition and Decision-making in Pulmonary Nodule Detection
Kundel, H. L., Nodine, C. F., & Carmody, D. (1978) · Investigative Radiology · doi:10.1097/00004424-197805000-00001 · Cited by 448
Wu, Y., Giger, M. L., Doi, K., Vyborny, C. J., Schmidt, R. A., & Metz, C. E. (1993) · Radiology · doi:10.1148/radiology.187.1.8451441 · Cited by 421
CHAN, H.-P., DOI, K., VYBRONY, C. J., SCHMIDT, R. A., METZ, C. E., LAM, K. L., OGURA, T., WU, Y., & MACMAHON, H. (1990) · Investigative Radiology · doi:10.1097/00004424-199010000-00006 · Cited by 359
Cited by
Systematic reviews: CRD's guidance for undertaking reviews in health care
Tacconelli, E. (2010) · The Lancet Infectious Diseases · doi:10.1016/s1473-3099(10)70065-7 · Cited by 3,245
Error and discrepancy in radiology: inevitable or avoidable?
Brady, A. P. (2017) · Insights into Imaging · doi:10.1007/s13244-016-0534-1 · Cited by 570
Interpretive Error in Radiology
Waite, S., Scott, J., Gale, B., Fuchs, T., Kolla, S., & Reede, D. (2017) · American Journal of Roentgenology · doi:10.2214/ajr.16.16963 · Cited by 271
Fool Me Twice: Delayed Diagnoses in Radiology With Emphasis on Perpetuated Errors
Kim, Y. W., & Mansfield, L. T. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.13.11493 · Cited by 259
Clinicians are right not to like Cohen's
de Vet, H. C. W., Mokkink, L. B., Terwee, C. B., Hoekstra, O. S., & Knol, D. L. (2013) · BMJ · doi:10.1136/bmj.f2125 · Cited by 250
Fitzgerald, R. (2001) · Clinical Radiology · doi:10.1053/crad.2001.0858 · Cited by 242
Empirical Study on Applications of Data Mining Techniques in Healthcare
Kaur, H., & Wasan, S. K. (2006) · Journal of Computer Science · doi:10.3844/jcssp.2006.194.200 · Cited by 233
Journey toward Computer-aided Diagnosis: Role of Image Texture Analysis
Tourassi, G. D. (1999) · Radiology · doi:10.1148/radiology.213.2.r99nv49317 · Cited by 233
How do radiologists do it? The influence of experience and training on searching for chest nodules
Manning, D., Ethell, S., Donovan, T., & Crawford, T. (2006) · Radiography · doi:10.1016/j.radi.2005.02.003 · Cited by 209
Spectrum of diagnostic errors in radiology
Pinto, A. (2010) · World Journal of Radiology · doi:10.4329/wjr.v2.i10.377 · Cited by 202
Kohli, M. D., Summers, R. M., & Geis, J. R. (2017) · Journal of Digital Imaging · doi:10.1007/s10278-017-9976-3 · Cited by 193
The past, present and future role of artificial intelligence in imaging
Fazal, M. I., Patel, M. E., Tye, J., & Gupta, Y. (2018) · European Journal of Radiology · doi:10.1016/j.ejrad.2018.06.020 · Cited by 179
The influence of clinical information on the reporting of CT by radiologists.
Leslie, A., Jones, A. J., & Goddard, P. R. (2000) · The British Journal of Radiology · doi:10.1259/bjr.73.874.11271897 · Cited by 172
Lucaya, J., Piqueras, J., García-Peña, P., Enríquez, G., García-Macías, M., & Sotil, J. (2000) · American Journal of Roentgenology · doi:10.2214/ajr.175.4.1750985 · Cited by 165
Accuracy of Diagnostic Procedures: Has It Improved Over the Past Five Decades?
Berlin, L. (2007) · American Journal of Roentgenology · doi:10.2214/ajr.06.1270 · Cited by 165
Sources of error in emergency ultrasonography
Pinto, A., Pinto, F., Faggian, A., Rubini, G., Caranci, F., Macarini, L., Genovese, E. A., & Brunese, L. (2013) · Critical Ultrasound Journal · doi:10.1186/2036-7902-5-s1-s1 · Cited by 162
Cohort study of structured reporting compared with conventional dictation
Johnson, A. J., Chen, M. Y. M., Swan, J. S., Applegate, K. E., & Littenberg, B. (2009) · Radiology · doi:10.1148/radiol.2531090138 · Cited by 139
Improving the radiologist-CAD interaction: designing for appropriate trust
Jorritsma, W., Cnossen, F., & van Ooijen, P. M. A. (2015) · Clinical Radiology · doi:10.1016/j.crad.2014.09.017 · Cited by 61
Pitfalls in Chest Radiographic Interpretation: Blind Spots
de Groot, P. M., Carter, B. W., Abbott, G. F., & Wu, C. C. (2015) · Seminars in Roentgenology · doi:10.1053/j.ro.2015.01.008 · Cited by 44
Observer Variation in Interpreting 18F-FDG PET/CT Findings for Lymphoma Staging
Hofman, M. S., Smeeton, N. C., Rankin, S. C., Nunan, T., & O'Doherty, M. J. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.064121 · Cited by 41
“Observer variation can be substantial, and differences between observers can outweigh purported differences between imaging techniques (2).”
Background
Metadata
- Authors
- Robinson, P. J.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 1997-11-01
- Volume
- 70
- Issue
- 839
- Pages
- 1085-1098
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2101504901
- Cited by
- 320
- References
- 58
- FWCI
- 7.94
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.