Estimation of paediatric organ and effective doses from dental cone beam CT using anthropomorphic phantoms
Open accessThe DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: Cone beam CT (CBCT) is an emerging X-ray technology applied in dentomaxillofacial imaging. Previous published studies have estimated the effective dose and radiation risks using adult anthropomorphic phantoms for a wide range of CBCT units and imaging protocols. METHODS: Measurements were made five dental CBCT units for a range of imaging protocols, using 10-year-old and adolescent phantoms and thermoluminescent dosimeters. The purpose of the study was to estimate paediatric organ and effective doses from dental CBCT. RESULTS: The average effective doses to the 10-year-old and adolescent phantoms were 116 μSv and 79 μSv, respectively, which are similar to adult doses. The salivary glands received the highest organ dose and there was a fourfold increase in the thyroid dose of the 10-year-old relative to that of the adolescent because of its smaller size. The remainder tissues and salivary and thyroid glands contributed most significantly to the effective dose for a 10-year-old, whereas for an adolescent the remainder tissues and the salivary glands contributed the most significantly. It was found that the percentage attributable lifetime mortality risks were 0.002% and 0.001% for a 10-year-old and an adolescent patient, respectively, which are considerably higher than the risk to an adult having received the same doses. CONCLUSION: It is therefore imperative that dental CBCT examinations on children should be fully justified over conventional X-ray imaging and that dose optimisation by field of view collimation is particularly important in young children.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,862
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,106
2007 Recommendations of the International Commission on Radiological Protection
Publ., I. (2008) · Annals of the ICRP · Cited by 1,788
Human Respiratory Tract Model for Radiological Protection
Icrp (1994) · Annals of the ICRP · Cited by 1,767
Valentin, J. (2002) · Annals of the ICRP · doi:10.1016/s0146-6453(03)00002-2 · Cited by 1,754
Solid Cancer Incidence in Atomic Bomb Survivors: 1958–1998
Preston, D. L., Ron, E., Tokuoka, S., Funamoto, S., Nishi, N., Soda, M., Mabuchi, K., & Kodama, K. (2007) · Radiation Research · doi:10.1667/rr0763.1 · Cited by 1,753 · cited 1×
“The resulting risk factors are primarily based on the life span study (LSS) of atomic bomb survivors [36, 37].”
BackgroundRecommendations of the International Commission on Radiological Protection
(1959) · Health Physics · doi:10.1097/00004032-195901000-00001 · Cited by 1,703
Preston, D. L., Shimizu, Y., Pierce, D. A., Suyama, A., & Mabuchi, K. (2003) · Radiation Research · doi:10.1667/rr3049 · Cited by 1,172
Cancer risks from diagnostic radiology
HALL, E. J., & BRENNER, D. J. (2008) · The British Journal of Radiology · doi:10.1259/bjr/01948454 · Cited by 915 · cited 1×
“The risk decreases linearly with no threshold for doses below 100 mSv [26, 28, 38].”
BackgroundComparative dosimetry of dental CBCT devices and 64-slice CT for oral and maxillofacial radiology
Ludlow, J. B., & Ivanovic, M. (2008) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2008.03.018 · Cited by 872 · cited 1×
“Similar to Ludlow and colleagues [15, 19], Roberts et al [14], Suomalainen et al [18] and ICRP 66 [31], it was assumed that the dose to the oral mucosa equals the dose to the salivary glands; the dose to the lymph nodes and muscle equals the average dose to the thyroid gland, submandibular and parotid glands; and the…”
ResultDosimetry of 3 CBCT devices for oral and maxillofacial radiology: CB Mercuray, NewTom 3G and i-CAT
Ludlow, J., Davies-Ludlow, L., Brooks, S., & Howerton, W. (2006) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/14340323 · Cited by 851 · cited 1×
“Similar to Ludlow and colleagues [15, 19], Roberts et al [14], Suomalainen et al [18] and ICRP 66 [31], it was assumed that the dose to the oral mucosa equals the dose to the salivary glands; the dose to the lymph nodes and muscle equals the average dose to the thyroid gland, submandibular and parotid glands; and the…”
ResultRadiation-Related Cancer Risks at Low Doses among Atomic Bomb Survivors
Pierce, D. A., & Preston, D. L. (2000) · Radiation Research · doi:10.1667/0033-7587(2000)154[0178:rrcral]2.0.co;2 · Cited by 757 · cited 3×
“Children have a longer life span to express any radiation-induced cancer and also they are inherently more radiosensitive because they have more dividing cells [26, 27].”
BackgroundBasic anatomical and physiological data for use in radiological protection : reference values
Valentin, J. (2002) · Medical Entomology and Zoology · Cited by 680
Endodontic Applications of Cone-Beam Volumetric Tomography
COTTON, T., GEISLER, T., HOLDEN, D., SCHWARTZ, S., & SCHINDLER, W. (2007) · Journal of Endodontics · doi:10.1016/j.joen.2007.06.011 · Cited by 633
Estimating cancer risks from pediatric CT: going from the qualitative to the quantitative
Brenner, D. J. (2002) · Pediatric Radiology · doi:10.1007/s00247-002-0671-1 · Cited by 554 · cited 4×
“Children have a longer life span to express any radiation-induced cancer and also they are inherently more radiosensitive because they have more dividing cells [26, 27].”
BackgroundInfluentialState-of-the-art on cone beam CT imaging for preoperative planning of implant placement
Guerrero, M. E., Jacobs, R., Loubele, M., Schutyser, F., Suetens, P., & van Steenberghe, D. (2006) · Clinical Oral Investigations · doi:10.1007/s00784-005-0031-2 · Cited by 371
Horner, K., Islam, M., Flygare, L., Tsiklakis, K., & Whaites, E. (2009) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/74941012 · Cited by 370 · cited 1×
“This clearly underlines the importance of limiting field of view as a basic principle [34, 35] of CBCT use but also indicates the even greater significance of this optimisation in younger children.”
BackgroundSelf-citationRadiation absorbed in maxillofacial imaging with a new dental computed tomography device
Mah, J. K., Danforth, R. A., Bumann, A., & Hatcher, D. (2003) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/s1079-2104(03)00350-0 · Cited by 345
Clinical indications for digital volume tomography in oral and maxillofacial surgery
Ziegler, C. M., Wörtche, R., Brief, J., & Haßfeld, S. (2002) · Dentomaxillofacial Radiology · doi:10.1038/sj/dmfr/4600680 · Cited by 328
Dose reduction in maxillofacial imaging using low dose Cone Beam CT
Tsiklakis, K., Donta, C., Gavala, S., Karayianni, K., Kamenopoulou, V., & Hourdakis, C. J. (2005) · European Journal of Radiology · doi:10.1016/j.ejrad.2005.05.011 · Cited by 327
Richmond, C. R. (1985) · International Journal of Radiation Biology and Related Studies in Physics, Chemistry and Medicine · doi:10.1080/09553008514551281 · Cited by 305
Current Products and Practice: Three-dimensional cone beam computerized tomography in orthodontics
Kau, C. H., Richmond, S., Palomo, J. M., & Hans, M. G. (2005) · Journal of Orthodontics · doi:10.1179/146531205225021285 · Cited by 268
Clinical indications for digital volume tomography in oral and maxillofacial surgery
Ziegler, C. M., Woertche, R., Brief, J., & Hassfeld, S. (2002) · Dentomaxillofacial Radiology · doi:10.1038/sj.dmfr.4600680 · Cited by 224
Current concepts in maxillofacial imaging
Boeddinghaus, R., & Whyte, A. (2008) · European Journal of Radiology · doi:10.1016/j.ejrad.2007.11.019 · Cited by 218
Radiation exposure of the UK population from medical and dental x-ray examinations
Hart, D. B., & Wall, B. F. (2001) · Cited by 195
Evaluation of the Linear-Nonthreshold Dose-Response Model for Ionizing Radiation
Becker, K. (2002) · Health Physics · doi:10.1097/00004032-200202000-00014 · Cited by 188
Hirsch, E., Wolf, U., Heinicke, F., & Silva, M. (2008) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/23424132 · Cited by 161
Management of Impacted Cuspids Using 3-D Volumetric Imaging
Mah, J. K., Enciso, R., & Jorgensen, M. (2003) · Journal of the California Dental Association · doi:10.1080/19424396.2003.12224266 · Cited by 45
Cited by
Ludlow, J. B., Timothy, R., Walker, C., Hunter, R., Benavides, E., Samuelson, D. B., & Scheske, M. J. (2015) · Dentomaxillofacial Radiology · doi:10.1259/dmfr.20140197 · Cited by 487
Bornstein, M., Scarfe, W., Vaughn, V., & Jacobs, R. (2014) · The International Journal of Oral & Maxillofacial Implants · doi:10.11607/jomi.2014suppl.g1.4 · Cited by 361
(2013) · Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology · doi:10.1016/j.oooo.2013.06.002 · Cited by 353
Cone-beam CT in paediatric dentistry: DIMITRA project position statement
On behalf of the DIMITRA Research Group, H. D. B., Oenning, A. C., Jacobs, R., Pauwels, R., Stratis, A., Hedesiu, M., & Salmon, B. (2018) · Pediatric Radiology · doi:10.1007/s00247-017-4012-9 · Cited by 313
Self-citation
Metadata
- Authors
- Theodorakou, C., Walker, A., Horner, K., Pauwels, R., Bogaerts, R., Jacobs Dds, R., & The Sedentexct Project Consortium
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2012-02
- Volume
- 85
- Issue
- 1010
- Pages
- 153-160
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W1989660091
- Cited by
- 173
- References
- 28
- FWCI
- 17.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.