Adult patient radiation doses from non-cardiac CT examinations: a review of published results
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: CT is a valuable tool in diagnostic radiology but it is also associated with higher patient radiation doses compared with planar radiography. The aim of this article is to review patient dose for the most common types of CT examinations reported during the past 19 years. METHODS: Reported dosimetric quantities were compared with the European diagnostic reference levels (DRLs). Effective doses were assessed with respect to the publication year and scanner technology (i.e. single-slice vs multislice). RESULTS: Considerable variation of reported values among studies was attributed to variations in both examination protocol and scanner design. Median weighted CT dose index (CTDI(w)) and dose length product (DLP) are below the proposed DRLs; however, for individual studies the DRLs are exceeded. Median reported effective doses for the most frequent CT examinations were: head, 1.9 mSv (0.3-8.2 mSv); chest, 7.5 mSv (0.3-26.0 mSv); abdomen, 7.9 mSv (1.4-31.2 mSv); and pelvis, 7.6 mSv (2.5-36.5 mSv). CONCLUSION: The introduction of mechanisms for dose reduction resulted in significantly lower patient effective doses for CT examinations of the head, chest and abdomen reported by studies published after 1995. Owing to the limited number of studies reporting patient doses for multislice CT examinations the statistical power to detect differences with single-slice scanners is not yet adequate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ngaile, J. E., Msaki, P., & Kazema, R. (2006) · Journal of Radiological Protection · doi:10.1088/0952-4746/26/2/006 · Cited by 37 · cited 6×
“It is anticipated that variation of CTDIw among studies can be attributed to intrinsic differences among the makes and models of CT scanners such as beam geometry, radiation quality, number of detector rows, absorption and scattered X-rays [24].”
BackgroundInfluential
Cited by
A review of patient dose and optimisation methods in adult and paediatric CT scanning
Dougeni, E., Faulkner, K., & Panayiotakis, G. (2012) · European Journal of Radiology · doi:10.1016/j.ejrad.2011.05.025 · Cited by 185
Self-citationRadaideh, K., Al-Radaideh, A., Ramli, R. M., Saleh, A., & Alshayeb, R. (2023) · Polish Journal of Medical Physics and Engineering · doi:10.2478/pjmpe-2023-0003 · Cited by 16
“Furthermore, Greece recorded lower updated dose levels where the recent CTDI vol and effective dose levels were lower (16 mGy, 11.4 mSv, respectively) 36 than the old ones (35 mGy, 11.7 mSv, respectively) 23 .”
InfluentialVarghese, B., Kandanga, I., Puthussery, P., Vijayan, D., Babu, S. P. H., Aneesh, M. K., Noufal, M., Binu, E. V., Babu, A. C., James, S. M., et al. (2018) · Indian Journal of Radiology and Imaging · doi:10.4103/ijri.ijri_394_17 · Cited by 12
Age-specific DRLs for pediatric brain CT: A review for exploring the practices in Saudi Arabia
Aljuaid, L. M., Althobaiti, S. F., Althobaiti, A. A., Alsufyani, A. H., Alotaibi, M. H., Elkhader, B. A., Osman, H., Althoibe, M. M., Raafat, B. M., Dahlawi, H. A., et al. (2025) · Applied Radiation and Isotopes · doi:10.1016/j.apradiso.2025.111664 · Cited by 6
Metadata
- Authors
- Pantos, I., Thalassinou, S., Argentos, S., Kelekis, N. L., Panayiotakis, G., & Efstathopoulos, E. P.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2011-04
- Volume
- 84
- Issue
- 1000
- Pages
- 293-303
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2144708146
- Cited by
- 85
- References
- 1
- FWCI
- 5.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.