Towards establishment of the national reference dose levels from computed tomography examinations in Tanzania
Open accessAbstract
Without the knowledge of reference dose levels (RDLs) from computed tomography (CT) examinations, the optimal dose to patients undergoing CT examinations cannot be realised. The aim of this study was therefore to assess the radiation dose levels from CT examinations according to reference dose quantities proposed by the European Commission (EC) guidelines. The dosimetric quantities proposed in the EC for CT are weighted CT dose index (CTDI(w)) for a single slice and dose-length product (DLP) for a complete examination. The RDLs from five common CT examinations were obtained from eight hospitals. The RDLs in terms of CTDI(w) and DLP were estimated from measurements of CTDI in standard phantoms using typical exposure parameters. Mean values of CTDI(w) for head and lumbar spine had a range of 25-77 and 18-47 mGy, respectively, while those for chest, abdomen and pelvis had a range of about 11-25 mGy, respectively. Mean values of DLP for head, chest and abdomen had a range of 610-1684, 496-992 and 717-1428 mGy cm, respectively, while those for lumbar spine and pelvis had a range of 200-382 and 526-1302 mGy cm, respectively. Wide variations of mean CTDI(w) and DLP values among hospitals observed for similar CT examinations were mainly attributed to the variations of CT scanning protocols and scanner types. The mean CTDI(w) values per examination for almost all hospitals were below proposed RDLs, while the mean DLP values per examination were almost all above the proposed RDLs for all except one hospital. These were mainly influenced by the large scan length used in Tanzanian hospitals. In order to achieve the required level of dose for establishment of the national RDLs, it was concluded that further investigation of optimization of scanning protocols is needed.
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Without knowledge of diagnostic reference levels (DRLs) from CT examinations, the optimal dose for patients undergoing CT examinations cannot be realised.
“Without the knowledge of diagnostic reference levels (DRLs) from CT examinations, the optimal dose for patients undergoing CT examinations cannot be realised [2].”
From Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels (2022) · cites this paper as [2]
The Introduction says that without CT reference dose levels it would be difficult to assess how well patient doses are optimised in Tanzania, and describes reference levels as a first step in optimisation. The claim goes further by saying optimal doses cannot be realised without them, rather than that optimisation is difficult to assess. (LLM, conf=0.86)
Experimental — accuracy not yet measuredWide variations of the mean weighted CTDI (CTDIw) and DLP values for similar CT scan examinations amongst Tanzanian hospitals were mainly attributed to the variations in CT scanning protocols and scanner types.
“Wide variations of the mean weighted CTDI (CTDIw) and DLP values for similar CT scan examinations amongst Tanzanian hospitals were mainly attributed to the variations in CT scanning protocols and scanner types.”
From Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels (2022) · cites this paper as [2]
The Tanzanian DLP values were mainly influenced by the large scan length used.
“These were mainly influenced by the large scan length used in these studies.”
From Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels (2022) · cites this paper as [2]
In Tanzania, the mean CTDI(w) values per examination for almost all hospitals were below the proposed DRLs, while the mean DLP values per examination were almost all above the proposed DRLs for all except one hospital.
“The mean CTDI(w) values per examination for almost all hospitals were below the proposed DRLs, while the mean DLP values per examination were almost all above the proposed DRLs for all except one hospital.”
From Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels (2022) · cites this paper as [2]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Cites
Recommendations of the International Commission on Radiological Protection
(1961) · Postgraduate Medical Journal · doi:10.1136/pgmj.37.425.168-b · Cited by 5,868 · see citing works
Estimated Risks of Radiation-Induced Fatal Cancer from Pediatric CT
Brenner, D. J., Elliston, C. D., Hall, E. J., & Berdon, W. E. (2001) · American Journal of Roentgenology · doi:10.2214/ajr.176.2.1760289 · Cited by 3,222 · see citing works
AAPM/RSNA Physics Tutorial for Residents: Topics in CT
McNitt‐Gray, M. F. (2002) · Radiographics · doi:10.1148/rg.226025128 · Cited by 612 · see citing works
Performance evaluation of a multi-slice CT system
McCollough, C. H., & Zink, F. E. (1999) · Medical Physics · doi:10.1118/1.598777 · Cited by 388 · see citing works
Managing patient dose in computed tomography
(2000) · Annals of the ICRP · doi:10.1016/s0146-6453(01)00049-5 · Cited by 376 · see citing works
Rothenberg, L. N., & Pentlow, K. S. (1992) · Radiographics · doi:10.1148/radiographics.12.6.1439023 · Cited by 192 · see citing works
Dosimetry for optimisation of patient protection in computed tomography
Jessen, K. A., Shrimpton, P. C., Geleijns, J., Panzer, W., & Tosi, G. (1999) · Applied Radiation and Isotopes · doi:10.1016/s0969-8043(98)00024-4 · Cited by 188 · see citing works
Reference Doses in Computed Tomography
Shrimpton, P. C., Jessen, K. A., Geleijns, J., Panzer, W., & Tosi, G. (1998) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a032542 · Cited by 36 · see citing works
Analysis of Factors Influencing Patient Doses from CT in Norway
Olerud, H. M. (1997) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a032039 · Cited by 34 · see citing works
Papadimitriou, D., Perris, A., Manetou, A., Molfetas, M., Panagiotakis, N., Lyra-Georgosopoulou, M., Hourdakis, K., Κόττου, Σ., Tosi, G., Origgi, D., et al. (2003) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a006162 · Cited by 32 · see citing works
Analyses and applications of single scan dose profiles in computed tomography
Tsai, H., Tung, C. J., Huang, M., & Wan, Y. (2003) · Medical Physics · doi:10.1118/1.1590315 · Cited by 29 · see citing works
Image quality and dose evaluation in spiral chest CT examinations of patients with lung carcinoma
Morán, L. M., Rodriguez, R. J., Calzado, A., Turrero, A., Arenas, A. P., Cuevas, A., García-Castaño, B., Gómez, N., & Moran, P. R. (2004) · British Journal of Radiology · doi:10.1259/bjr/71539623 · Cited by 9 · see citing works
Flagged first, then by citations
Research works printed but not linked: 3
- [2]2. Gray J E 2001 Radiological protection issues in mammography and computed tomography Proc. Int. Conf. (Malaga, Spain, March, 2001) (Vienna: IAEA) pp 183-200
- [10]10. NRPB (National Radiological Protection Board) 2005 Doses from computed tomography (CT) examinations in the UK-2003 Review NRPB-W67 (Chilton: NRPB)
- [13]13. Rosenstein M 2001 Diagnostic reference levels in medical imaging Proc. Int. Conf. (Malaga, Spain, March) (Vienna: IAEA) pp 241-63
Cited by
Sorted by citations
Radiation Exposure from Musculoskeletal Computerized Tomographic Scans
Biswas, D., Bible, J. E., Bohan, M., Simpson, A. K., Whang, P. G., & Grauer, J. N. (2009) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.h.01199 · Cited by 441 · see citing works
Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They?
Huda, W., & Mettler, F. A. (2010) · Radiology · doi:10.1148/radiol.10100297 · Cited by 209 · see citing works
Establishment of CT diagnostic reference levels in Ireland
Foley, S. J., McEntee, M. F., & Rainford, L. A. (2012) · The British Journal of Radiology · doi:10.1259/bjr/15839549 · Cited by 186 · see citing works
Establishing national diagnostic reference levels (DRLs) for computed tomography in Egypt
Salama, D. H., Vassileva, J., Mahdaly, G., Shawki, M., Salama, A., Gilley, D., & Rehani, M. M. (2017) · Physica Medica · doi:10.1016/j.ejmp.2017.05.050 · Cited by 98 · see citing works
Adult patient radiation doses from non-cardiac CT examinations: a review of published results
Pantos, I., Θαλασσινού, Σ., Argentos, S., Kelekis, N., Panayiotakis, G., & EFSTATHOPOULOS, E. P. (2011) · British Journal of Radiology · doi:10.1259/bjr/69070614 · Cited by 85 · see citing works
NATIONAL DIAGNOSTIC REFERENCE LEVEL INITIATIVE FOR COMPUTED TOMOGRAPHY EXAMINATIONS IN KENYA
Korir, G. K., Wambani, J. S., Korir, I. K., Tries, M. A., & Boen, P. K. (2015) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncv020 · Cited by 52 · see citing works
Tsai, H., Tung, C. J., Yu, C., & Tyan, Y.-S. (2007) · Medical Physics · doi:10.1118/1.2712412 · Cited by 46 · see citing works
Hwang, J., Do, K., Yang, D. H., Cho, Y. A., Yoon, H.-K., Lee, J. S., & Koo, H. J. (2015) · Medicine · doi:10.1097/md.0000000000002146 · Cited by 39 · see citing works
Qurashi, A. A., Rainford, L. A., & Foley, S. J. (2014) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncu343 · Cited by 37 · see citing works
Garba, I., Zarb, F. L., McEntee, M. F., & Fabri, S. G. (2020) · Radiography · doi:10.1016/j.radi.2020.08.011 · Cited by 27 · see citing works
Survey of computed tomography technique and radiation dose in Sudanese hospitals
Suliman, I. I., Abdalla, S. E., Ahmed, N. A., Galal, M., & Salih, I. (2011) · European Journal of Radiology · doi:10.1016/j.ejrad.2010.12.050 · Cited by 27 · see citing works
Erem, G., Ameda, F., Otike, C., Olwit, W., Mubuuke, A. G., Schandorf, C., Kisolo, A., & Kawooya, M. G. (2022) · BMC Medical Imaging · doi:10.1186/s12880-022-00838-x · Cited by 22 · see citing works
“Without the knowledge of diagnostic reference levels (DRLs) from CT examinations, the optimal dose for patients undergoing CT examinations cannot be realised [2].”
Background(2010) · PubMed · Cited by 17 · see citing works
Gervaise, A., Louis, M., Batch, T., Lœuille, D., Noël, A., Guillemin, F., & Blum, A. (2010) · Journal de Radiologie · doi:10.1016/s0221-0363(10)70115-3 · Cited by 16 · see citing works
Zarb, F. L., McEntee, M. F., & Rainford, L. A. (2011) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr393 · Cited by 15 · see citing works
Radiation dosimetry assessment of routine CT scanning protocols used in Western Australia
Moorin, R. E., Forsyth, R. K., Gibson, D. A. J., & Fox, R. A. (2013) · Journal of Radiological Protection · doi:10.1088/0952-4746/33/2/295 · Cited by 13 · see citing works
Local Diagnostic Reference Levels for Common Adult Computed Tomography Procedures in Addis Ababa
Dellie, S. T., Tesfaw, A. F., Kumsa, M. J., & Tolawak, B. T. (2023) · Dose-Response · doi:10.1177/15593258231171492 · Cited by 11 · see citing works
Sun, H., Gao, F., Li, N., & Liu, C. (2013) · Acta Radiologica · doi:10.1177/0284185113490151 · Cited by 11 · see citing works
Humadi, A., Dawood, S., Halldin, K., & Freeman, B. J. C. (2017) · Global Spine Journal · doi:10.1177/2192568217701722 · Cited by 9 · see citing works
Patient doses using multidetector computed tomography scanners in Kenya
Korir, G. K., Wambani, J. S., & Korir, I. K. (2012) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncr484 · Cited by 8 · see citing works
Informed consent for computed tomography
Merck, L. H., Hauck, M., Houry, D. E., Lowery-North, D. W., Hemphill, R. R., & Applegate, K. E. (2010) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2010.09.006 · Cited by 7 · see citing works
Establishment of diagnostic reference levels in low-dose renal computed tomography
Rawashdeh, M. A., & Saade, C. (2022) · Acta Radiologica · doi:10.1177/02841851221095238 · Cited by 7 · see citing works
Frequency and Collective Dose of Medical Procedures in Kenya
Korir, G. K., Wambani, J. S., Korir, I. K., Tries, M. A., & Kidali, M. M. (2013) · Health Physics · doi:10.1097/hp.0b013e31829c35f4 · Cited by 6 · see citing works
Rationale for National and Local Dose Reference Levels and Collective Effective Dose in CT
Zarb, F. L., Rainford, L. A., Foley, S. J., & McEntee, M. F. (2009) · Journal of medical imaging and radiation sciences · doi:10.1016/j.jmir.2009.06.001 · Cited by 5 · see citing works
Cho, P.-K. (2012) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncs264 · Cited by 4 · see citing works
Radiation doses during computed tomography scan imaging in Hassan II Hospital, Agadir, Morocco
Semghouli, S., Amaoui, B., & Wakrim, S. (2022) · Pan African Medical Journal · doi:10.11604/pamj.2022.41.290.25090 · Cited by 4 · see citing works
Saeed, M. K., Abdallah, Y. M. Y., Hakeem, I. Y., & Alqahtani, F. F. (2023) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2023.110990 · Cited by 3 · see citing works
Curran, T.-I., Maher, M. M., McLaughlin, P. D., Coffey, F., & O’Neill, S. B. (2020) · medRxiv · doi:10.1101/2020.04.08.20057059 · Cited by 3 · see citing works
Ciraj‐Bjelac, O., Arandjic, D., Košutić, D., & Kovačević, M. S. (2010) · Cited by 1 · see citing works
Ngaile, J. E., Msaki, P., Suleiman, S. A., Chuma, F. M., Muhogora, W. E., & Jusabani, A. (2021) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncab159 · Cited by 1 · see citing works
Self-citationAbdallah, Y. M. Y., & Alamoudi, A. (2025) · Radiation Physics and Chemistry · doi:10.1016/j.radphyschem.2025.113085 · Cited by 1 · see citing works
Measurement of radiation dose in multi-slice computed tomography
Maharjan, S., Prajapati, S., & Panta, O. B. (2016) · Bangabandhu Sheikh Mujib Medical University Journal · doi:10.3329/bsmmuj.v9i4.30143 · Cited by 1 · see citing works
Radiation Exposure from Musculoskeletal Computerized
Biswas, D., Bible, J. E., Bohan, M., Simpson, A. K., Whang, P. G., & Grauer, J. N. (2009)
Saeed, M. K., Abdallah, Y. M. Y., Suilman, A., Omer, M., & Ahmed, A. S. (2023) · Current Medical Imaging Formerly Current Medical Imaging Reviews · doi:10.2174/1573405619666230322102011
Radiation exposure during CT procedures in Tanzania
Ngoye, W. M., Ndukeki, M., Muhogora, W. E., Jusabani, A., Ngaile, J. E., Ngoya, P. S., Sungura, R., Ngatunga, C., Hashmi, N., Makungu, H., et al. (2023) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncad274
Self-citationÉvaluation dosimétrique des examens de tomodensitométrie (TDM) adulte au Bénin
Fachinan, O. H., Houndetoungan, G. D., Alfonce, A., Zohizalan, T. A., Bathily, E. H. A. L., Kofi-Mensa, S. D. T., & Marcellin, A.-G. K. (2025) · Radioprotection · doi:10.1051/radiopro/2025042
- Authors
- Ngaile, J. E., Msaki, P., & Kazema, R.
- Affiliations
- University of Dar es Salaam (TZ)
- Muhimbili University of Health and Allied Sciences (TZ)
- Corresponding author
- Kazema, R
- ORCID
- Ngaile, J E
- Venue
- Journal of Radiological Protection
- Publisher
- IOP Publishing
- Published
- 2006-05-26
- Volume
- 26
- Issue
- 2
- Pages
- 213-225
- ISSN
- 0952-4746 (ISSN-L)
- 1361-6498
- OpenAlex
- W2086233086
- Cited by
- 37
- References
- 12
- Citations by year
- 2025: 2 · 2023: 4 · 2022: 3 · 2021: 1 · 2020: 2 · 2017: 2 · 2016: 2 · 2015: 2 · 2014: 1 · 2013: 3 · 2012: 3
- FWCI
- 1.07
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Locations
- Journal of Radiological Protection (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Digital Radiography and Breast Imaging
- Keywords
- computed tomography, radiation dose, dose-length product, CT scanning protocols, head CT, lumbar spine CT, Tanzania
- MeSH terms
- Body Burden, European Union, Humans, Radiation Dosage, Radiometry, Reference Values, Relative Biological Effectiveness, Risk Factors, Tanzania, Tomography, X-Ray Computed, Risk Assessment
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review