Cited by 37Radiation Dose and ImagingAdvanced Radiotherapy TechniquesDigital Radiography and Breast Imaging

Towards establishment of the national reference dose levels from computed tomography examinations in Tanzania

Open access
Ngaile, J E, Msaki, P, Kazema, R·2006·Journal of Radiological Protection

Abstract

Without the knowledge of reference dose levels (RDLs) from computed tomography (CT) examinations, the optimal dose to patients undergoing CT examinations cannot be realised. The aim of this study was therefore to assess the radiation dose levels from CT examinations according to reference dose quantities proposed by the European Commission (EC) guidelines. The dosimetric quantities proposed in the EC for CT are weighted CT dose index (CTDI(w)) for a single slice and dose-length product (DLP) for a complete examination. The RDLs from five common CT examinations were obtained from eight hospitals. The RDLs in terms of CTDI(w) and DLP were estimated from measurements of CTDI in standard phantoms using typical exposure parameters. Mean values of CTDI(w) for head and lumbar spine had a range of 25-77 and 18-47 mGy, respectively, while those for chest, abdomen and pelvis had a range of about 11-25 mGy, respectively. Mean values of DLP for head, chest and abdomen had a range of 610-1684, 496-992 and 717-1428 mGy cm, respectively, while those for lumbar spine and pelvis had a range of 200-382 and 526-1302 mGy cm, respectively. Wide variations of mean CTDI(w) and DLP values among hospitals observed for similar CT examinations were mainly attributed to the variations of CT scanning protocols and scanner types. The mean CTDI(w) values per examination for almost all hospitals were below proposed RDLs, while the mean DLP values per examination were almost all above the proposed RDLs for all except one hospital. These were mainly influenced by the large scan length used in Tanzanian hospitals. In order to achieve the required level of dose for establishment of the national RDLs, it was concluded that further investigation of optimization of scanning protocols is needed.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0952-4746/26/2/006

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Without knowledge of diagnostic reference levels (DRLs) from CT examinations, the optimal dose for patients undergoing CT examinations cannot be realised.

    “Without the knowledge of diagnostic reference levels (DRLs) from CT examinations, the optimal dose for patients undergoing CT examinations cannot be realised [2].”

    From Adult Computed Tomography examinations in Uganda: Towards determining the National Diagnostic Reference Levels (2022) · cites this paper as [2]

    The Introduction says that without CT reference dose levels it would be difficult to assess how well patient doses are optimised in Tanzania, and describes reference levels as a first step in optimisation. The claim goes further by saying optimal doses cannot be realised without them, rather than that optimisation is difficult to assess. (LLM, conf=0.86)

    Experimental — accuracy not yet measured
  • Wide variations of the mean weighted CTDI (CTDIw) and DLP values for similar CT scan examinations amongst Tanzanian hospitals were mainly attributed to the variations in CT scanning protocols and scanner types.

    “Wide variations of the mean weighted CTDI (CTDIw) and DLP values for similar CT scan examinations amongst Tanzanian hospitals were mainly attributed to the variations in CT scanning protocols and scanner types.”
  • The Tanzanian DLP values were mainly influenced by the large scan length used.

    “These were mainly influenced by the large scan length used in these studies.”
  • In Tanzania, the mean CTDI(w) values per examination for almost all hospitals were below the proposed DRLs, while the mean DLP values per examination were almost all above the proposed DRLs for all except one hospital.

    “The mean CTDI(w) values per examination for almost all hospitals were below the proposed DRLs, while the mean DLP values per examination were almost all above the proposed DRLs for all except one hospital.”

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Research works printed but not linked: 3

  1. [2]2. Gray J E 2001 Radiological protection issues in mammography and computed tomography Proc. Int. Conf. (Malaga, Spain, March, 2001) (Vienna: IAEA) pp 183-200
  2. [10]10. NRPB (National Radiological Protection Board) 2005 Doses from computed tomography (CT) examinations in the UK-2003 Review NRPB-W67 (Chilton: NRPB)
  3. [13]13. Rosenstein M 2001 Diagnostic reference levels in medical imaging Proc. Int. Conf. (Malaga, Spain, March) (Vienna: IAEA) pp 241-63

Cited by

Sorted by citations

Authors
Ngaile, J. E., Msaki, P., & Kazema, R.
Affiliations
  • University of Dar es Salaam (TZ)
  • Muhimbili University of Health and Allied Sciences (TZ)
Corresponding author
Kazema, R
Venue
Journal of Radiological Protection
Published
2006-05-26
Volume
26
Issue
2
Pages
213-225
ISSN
  • 0952-4746 (ISSN-L)
  • 1361-6498
OpenAlex
W2086233086
Cited by
37
References
12
Citations by year
2025: 2 · 2023: 4 · 2022: 3 · 2021: 1 · 2020: 2 · 2017: 2 · 2016: 2 · 2015: 2 · 2014: 1 · 2013: 3 · 2012: 3
FWCI
1.07
Type
journal article
Language
en
Open access
Locations
  • Journal of Radiological Protection (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
  • Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
  • Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Digital Radiography and Breast Imaging
Keywords
computed tomography, radiation dose, dose-length product, CT scanning protocols, head CT, lumbar spine CT, Tanzania
MeSH terms
Body Burden, European Union, Humans, Radiation Dosage, Radiometry, Reference Values, Relative Biological Effectiveness, Risk Factors, Tanzania, Tomography, X-Ray Computed, Risk Assessment

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review