The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Radiation dose metrics in multidetector computed tomography examinations: A multicentre retrospective study from seven tertiary care hospitals in Kerala, South India
Open accessAbstract
Abstract Background: Presently, computed tomography (CT) is the most important source of medical radiation exposure. CT radiation doses vary considerably across institutions depending on the protocol and make of equipment. India does not yet have national or region-specific CT diagnostic reference levels. Aim: To evaluate radiation doses of consecutive multidetector CT (MDCT) examinations based on anatomic region, performed in 1 month, collected simultaneously from seven tertiary care hospitals in Kerala. Settings and Design: Descriptive study. Materials and Methods: We collected the CT radiation dose data of examinations from the seven collaborating tertiary care hospitals in Kerala, performed with MDCT scanners of five different makes. The data included anatomic region, number of phases, CT dose index (CTDIvol), dose-length product (DLP), and effective dose (ED) of each examinations and patient demographic data. Statistical Analysis: We calculated the 25th, 50th, and 75th percentiles of the CTDIvol, DLP, and ED according to anatomic region. We made descriptive comparisons of these results with corresponding data from other countries. Results: Of 3553 patients, head was the most frequently performed examination (60%), followed by abdomen (19%). For single-phase head examinations, 75th percentile of CTDIvolwas 68.1 mGy, DLP 1120 mGy-cm, and ED 2.1 mSv. The 75th percentiles of CTDIvol, DLP, and ED for single-phase abdomen examinations were 10.6, 509.3, and 7.7, and multiphase examinations were 14.6, 2666.9, and 40.8; single-phase chest examinations were 23.4, 916.7, and 13.38, and multiphase examinations were 19.9, 1737.6, and 25.36; single-phase neck were 24.9, 733.6, and 3.814, and multiphase neck were 24.9, 2076, and 10.79, respectively. Conclusion: This summary CT radiation dose data of most frequently performed anatomical regions could provide a starting point for institutional analysis of CT radiation doses, which in turn leads to meaningful optimization of CT.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The DRLs established in this study are lower than national and international benchmarks.
“demonstrating lower radiation doses than national and international benchmarks.”
From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [9]
The Results (page unavailable) say the study’s head DRL was comparable to the University of California study, while its chest, abdomen, and multiphase-neck DRLs were considerably higher—not lower. The Conclusion says a national CT-dose benchmark for India was anticipated in the future, rather than reporting that these DRLs fell below one. (LLM, conf=0.88)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredThe present study demonstrated the lowest radiation exposure for both dose descriptors compared with modern studies.
“The present study demonstrated the lowest radiation exposure for both dose descriptors.”
From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [9]
The Results report that this paper's diagnostic reference levels for chest, abdomen, and multiphase neck CT were considerably higher than those in the University of California study, while head CT levels were comparable. That contradicts attributing the lowest radiation exposure across both dose descriptors to this paper. (LLM, conf=0.86)
Checked by a reasoning model — may be wrong.
Experimental — accuracy not yet measuredStudies in Portugal reported CTDIvol 18 mGy and DLP 800 mGy·cm.
“studies conducted in Portugal (CTDIvol: 18 mGy, DLP: 800 mGy·cm) and Japan (CTDIvol: 18.2 mGy, DLP: 870.9 mGy·cm) reflect significantly higher dose levels. 9 14”
From Establishing Diagnostic Reference Level for Adult Abdomen and Pelvis CT Scans: A Benchmarking Study across BMI Groups (2026) · cites this paper as [9]
The Results section says the authors compared their Kerala dose data with data from other countries, but the passages in our copy do not identify Portugal or report the attributed CTDIvol of 18 mGy and DLP of 800 mGy·cm. Searches for Portugal and the specific values found no passage establishing them; the table contents are not present in the retrieved text. (LLM, conf=0.76)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Computed Tomography — An Increasing Source of Radiation Exposure
Brenner, D. J., & Hall, E. J. (2007) · New England Journal of Medicine · doi:10.1056/nejmra072149 · Cited by 8,738
The 2007 recommendations of the International Commission on Radiological Protection
Valentin, J. (2007) · Elsevier eBooks · Cited by 4,105
Preface, Executive Summary and Glossary
(2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.10.003 · Cited by 2,116
Benefits and costs, an eternal balance
Dixon, A. K. (2007) · Annals of the ICRP · doi:10.1016/j.icrp.2007.09.001 · Cited by 1,355
American College of Radiology White Paper on Radiation Dose in Medicine
Amis, E. S., Butler, P. F., Applegate, K. E., Birnbaum, S. B., Brateman, L. F., Hevezi, J. M., Mettler, F. A., Morin, R. L., Pentecost, M. J., Smith, G. G., et al. (2007) · Journal of the American College of Radiology · doi:10.1016/j.jacr.2007.03.002 · Cited by 902
Strategies for Reducing Radiation Dose in CT
McCollough, C. H., Primak, A. N., Braun, N., Kofler, J., Yu, L., & Christner, J. (2009) · Radiologic Clinics of North America · doi:10.1016/j.rcl.2008.10.006 · Cited by 842
Recommendations of the International Commission on Radiological Protection Publication 60
Icrp (1991) · Annals of the ICRP · Cited by 835
1990 Recommendations of the International Commission on Radiological Protection.
(1991) · PubMed · Cited by 602
MEDICAL RADIATION EXPOSURE IN THE U.S. IN 2006: PRELIMINARY RESULTS
Mettler, F. A., Thomadsen, B., Bhargavan, M., Gilley, D. B., Gray, J. E., Lipoti, J. A., McCrohan, J. L., Yoshizumi, T. T., & Mahesh, M. (2008) · Health Physics · doi:10.1097/01.hp.0000326333.42287.a2 · Cited by 507
Boone, J. M. (2007) · Medical Physics · doi:10.1118/1.2713240 · Cited by 418
U.S. Diagnostic Reference Levels and Achievable Doses for 10 Adult CT Examinations
Kanal, K. M., Butler, P. F., Sengupta, D., Bhargavan, M., Coombs, L. P., & Morin, R. L. (2017) · Radiology · doi:10.1148/radiol.2017161911 · Cited by 397
Volume CT Dose Index and Dose-Length Product Displayed during CT: What Good Are They?
Huda, W., & Mettler, F. A. (2010) · Radiology · doi:10.1148/radiol.10100297 · Cited by 209
Hart, D. B., HILLIER, M. C., & Wall, B. F. (2008) · British Journal of Radiology · doi:10.1259/bjr/12568539 · Cited by 208
CT scanning: A major source of radiation exposure
Wiest, P. W., Locken, J. A., Heintz, P. H., & Mettler, F. A. (2002) · Seminars in Ultrasound CT and MRI · doi:10.1016/s0887-2171(02)90011-9 · Cited by 173
Radiation Doses in Consecutive CT Examinations from Five University of California Medical Centers
Smith‐Bindman, R., Moghadassi, M., Wilson, N., et al. (2015) · Radiology · doi:10.1148/radiol.2015142728 · Cited by 127
(1996) · PubMed · Cited by 127
Vassileva, J., & Rehani, M. M. (2014) · American Journal of Roentgenology · doi:10.2214/ajr.14.12794 · Cited by 126
Diagnostic Reference Ranges for Pediatric Abdominal CT
Goske, M. J., Strauss, K. J., Coombs, L. P., et al. (2013) · Radiology · doi:10.1148/radiol.13120730 · Cited by 113
Adult patient radiation doses from non-cardiac CT examinations: a review of published results
Pantos, I., Θαλασσινού, Σ., Argentos, S., Kelekis, N., Panayiotakis, G., & EFSTATHOPOULOS, E. P. (2011) · British Journal of Radiology · doi:10.1259/bjr/69070614 · Cited by 85
Govindarajan, K., Saravanakumar, A., Vaideki, K., et al. (2014) · Journal of Medical Physics · doi:10.4103/0971-6203.125509 · Cited by 32
Paolicchi, F., Faggioni, L., Bastiani, L., et al. (2013) · Insights into Imaging · doi:10.1007/s13244-013-0241-0 · Cited by 26
Rosenstein, M. (2008) · Health Physics · doi:10.1097/01.hp.0000326331.35187.63 · Cited by 26
Establishment of CT diagnostic reference levels in select procedures in South India
Saravanakumar, A., Vaideki, K., Govindarajan, K., et al. (2016) · Internatuinal Journal of Radiation Research · doi:10.18869/acadpub.ijrr.14.4.341 · Cited by 20
Livingstone, R. S., & Dinakaran, P. M. (2011) · Journal of Medical Physics · doi:10.4103/0971-6203.75471 · Cited by 11
Estimation of dose reference levels in computed tomography for select procedures in Kerala, India
Govindarajan, K., Saravanakumar, A., Vaideki, K., et al. (2015) · Journal of Medical Physics · doi:10.4103/0971-6203.158701 · Cited by 7
Flagged first, then by citations
Research works printed but not linked: 2
- International Electrotechnical Commission, 2002, Medical Electrical Equipment. Part 2–44: Particular requirements for the safety of X-ray equipment for computed tomography. 2.1
- Radiological Protection and Safety in Medicine, 1996, ICRP publication 73, Ann ICRP, 26, 1
Cited by
Sorted by citations
M., J. M., U., R., U., S. K., Shetty, L., Dabholkar, A., & Ramachandraiah, C. (2026) · Indian Journal of Radiology and Imaging · doi:10.1055/s-0045-1806868 · Cited by 2
Metadata
- Authors
- Varghese, B., Kandanga, I., Puthussery, P., Vijayan, D., Babu, S. P. H., Aneesh, M. K., Noufal, M., Binu, E. V., Babu, A. C., James, S. M., & Kumar, S.
- Affiliations
- Amala Institute of Medical Sciences (IN)
- Department of Radiodiagnosis, Govt Medical College, Thrissur, Kerala, India
- Travancore medicity medical College hospital (IN)
- Baby Memorial Hospital (IN)
- Jubilee Mission Medical College and Research Institute (IN)
- Star Care Hospital, Kozhikode, Kerala, India
- Department of Radiodiagnosis, Daya Hospital, Thrissur, Kerala, India
- Department of Radiodiagnosis, Amala Institute of Medical Sciences, Kerala, India
- Corresponding author
- Varghese, Binoj
- ORCID
- Varghese, Binoj
- Venue
- Indian Journal of Radiology and Imaging
- Publisher
- Georg Thieme Verlag KG
- Published
- 2018-04
- Volume
- 28
- Issue
- 02
- Pages
- 250-257
- ISSN
- 0970-2016 (ISSN-L)
- 0971-3026
- 1998-3808
- PMC
- PMC6038221
- OpenAlex
- W2811053745
- Cited by
- 12
- References
- 25
- Citations by year
- 2026: 2 · 2025: 3 · 2024: 1 · 2023: 1 · 2021: 3 · 2020: 1 · 2019: 1
- FWCI
- 0.86
- Type
- journal article
- Language
- en
- Open access
- diamond
- doi.org
- Licence
- Locations
- Indian journal of radiology and imaging - new series/Indian journal of radiology and imaging/Indian Journal of Radiology & Imaging (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-sa)
- PubMed Central (publishedVersion, cc-by-nc-sa)
- PubMed (publishedVersion)
- DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiation Dose and Imaging
- Physical Sciences › Physics and Astronomy › Radiation › Advanced Radiotherapy Techniques
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Radiology practices and education
- Keywords
- multidetector computed tomography, CT radiation dose, diagnostic reference levels, volume CT dose index, dose-length product, effective dose, head CT, abdominal CT, chest CT, neck CT, dose optimization, Kerala, tertiary care hospital, patient demographics
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review