The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Whole-body adipose tissue analysis: comparison of MRI, CT and dual energy X-ray absorptiometry
Abstract
The aim of this study was to validate a recently proposed MRI-based T(1)-mapping method for analysis of whole-body adipose tissue (AT) using an established CT protocol as reference and to include results from dual energy X-ray absorptiometry (DEXA). 10 subjects, drawn from the Swedish Obese Subjects Sibling-pairs study, were examined using CT, MRI and DEXA. The CT analysis was based on 28 imaged slices. T(1) maps were calculated using contiguous MRI data from two different gradient echo sequences acquired using different flip angles. CT and MRI comparison was performed slice-wise and for the whole-body region. Fat weights were compared between all three modalities. Strong correlations (r > or = 0.977, p<0.0001) were found between MRI and CT whole-body and AT volumes. MRI visceral AT volume was underestimated by 0.79 +/- 0.75 l (p = 0.005), but total AT was not significantly different from that estimated by CT (MRI - CT = -0.61+/-1.17 l; p = 0.114). DEXA underestimated fat weights by 5.23 +/- 1.71 kg (p = 0.005) compared with CT. MRI underestimated whole-body volume by 2.03 +/- 1.61 l (p = 0.005) compared with CT. Weights estimated either by CT or by DEXA were not significantly different from weights measured using scales. In conclusion, strong correlations were found between whole-body AT results from CT, MRI-based T(1) mapping and DEXA. If the differences between the results from T(1)-mapping and CT-based analysis are accepted, the T(1)-mapping method allows fully automated post-processing of whole-body MRI data, allowing longitudinal whole-body studies that are also applicable for children and adolescents.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Lifestyle, diabetes, and cardiovascular risk factors 10 years after bariatric surgery
Sjöström, L., Lindroos, A.-K., Peltonen, M., Torgerson, J., Bouchard, C., Carlsson, B., Dahlgren, S., Larsson, B., Narbro, K., Sjöström, C. D., et al. (2004) · New England Journal of Medicine · doi:10.1056/nejmoa035622 · Cited by 4,457
Mechanisms linking obesity with cardiovascular disease
Van Gaal, L. F., Mertens, I. L., & De Block, C. E. (2006) · Nature · doi:10.1038/nature05487 · Cited by 2,814
Kistorp, C., & Svendsen, O. (1997) · European Journal of Clinical Nutrition · doi:10.1038/sj.ejcn.1600424 · Cited by 38
Cited by
Shepherd, J. A., Ng, B. K., Sommer, M. J., & Heymsfield, S. B. (2017) · Bone · doi:10.1016/j.bone.2017.06.010 · Cited by 460
Imaging of sarcopenia: old evidence and new insights
Albano, D., Messina, C., Vitale, J., & Sconfienza, L. M. (2020) · European Radiology · doi:10.1007/s00330-019-06573-2 · Cited by 400
Segmentation and quantification of adipose tissue by magnetic resonance imaging
Hu, H. H., Chen, J., & Shen, W. (2016) · Magnetic Resonance Materials in Physics, Biology and Medicine · doi:10.1007/s10334-015-0498-z · Cited by 90
Smartphone camera based assessment of adiposity: a validation study
Majmudar, M. D., Chandra, S., Yakkala, K., Kennedy, S., Agrawal, A., Sippel, M., Ramu, P., Chaudhri, A., Smith, B., Criminisi, A., et al. (2022) · npj Digital Medicine · doi:10.1038/s41746-022-00628-3 · Cited by 75
Grove, J., & Hung, Y.-J. (2017) · Journal of Physical Therapy and Sports Medicine · doi:10.35841/physical-therapy.1.1.5-11 · Cited by 6
Metadata
- Authors
- KULLBERG, J., BRANDBERG, J., ANGELHED, J.-E., FRIMMEL, H., BERGELIN, E., STRID, L., AHLSTRÖM, H., JOHANSSON, L., & LÖNN, L.
- Venue
- The British Journal of Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2009-02
- Volume
- 82
- Issue
- 974
- Pages
- 123-130
- ISSN
- 0007-1285 (ISSN-L)
- 1748-880X
- OpenAlex
- W2118126796
- Cited by
- 164
- References
- 3
- FWCI
- 5.12
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.