Geometric accuracy of the NewTom 9000 Cone Beam CT
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
OBJECTIVES: To determine the geometric accuracy of digital volume tomograms to assess their usability for implant planning. METHODS: A measuring object with 216 measuring points, whose geometry is exactly known, is X-rayed with a NewTom 9000 cone beam scanner; thereafter the geometry of the volume tomogram of the object is compared with the original body. RESULTS: Considering all three coordinate axes, geometric mean deviations of 0.13 +/- 0.09 mm with a maximum deviation of 0.3 mm were determined. These geometric deviations are below the resolution power of the volume tomograph. CONCLUSION: The digital volume tomographies of NewTom 9000 present images which are geometrically correct and, from a geometrical point of view, suitable for three-dimensional implant planning.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Accuracy of implant placement with a stereolithographic surgical guide.
Sarment, D. P., Sukovic, P., & Clinthorne, N. H. (2003) · PubMed · Cited by 584
Ludlow, J., Davies-Ludlow, L., & Brooks, S. (2003) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/26310390 · Cited by 463 · cited 1×
“The successful use of cone beam scan technique in dentomaxillofacial radiology has been reported for 5 years(1) – 3 and dosimetric examinations have proved the radiation dose of the cone beam computed tomography (CT) NewTom 9000 (NewTom AG, Marburg, Germany) to be significantly lower than that of other CT imaging meth…”
BackgroundRadiation absorbed in maxillofacial imaging with a new dental computed tomography device
Mah, J. K., Danforth, R. A., Bumann, A., & Hatcher, D. (2003) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/s1079-2104(03)00350-0 · Cited by 345
Clinical indications for digital volume tomography in oral and maxillofacial surgery
Ziegler, C. M., Wörtche, R., Brief, J., & Haßfeld, S. (2002) · Dentomaxillofacial Radiology · doi:10.1038/sj/dmfr/4600680 · Cited by 328
Self-citationClinical indications for digital volume tomography in oral and maxillofacial surgery
Ziegler, C. M., Woertche, R., Brief, J., & Hassfeld, S. (2002) · Dentomaxillofacial Radiology · doi:10.1038/sj.dmfr.4600680 · Cited by 224
Self-citationCone Beam CT for Pre-Surgical Assessment of Implant Sites
Hatcher, D. C., Dial, C., & Mayorga, C. (2003) · Journal of the California Dental Association · doi:10.1080/19424396.2003.12224265 · Cited by 216
Cited by
Internal Root Resorption: A Review
Patel, S., Ricucci, D., Durak, C., & Tay, F. (2010) · Journal of Endodontics · doi:10.1016/j.joen.2010.03.014 · Cited by 347
Honey, O. B., Scarfe, W. C., Hilgers, M. J., Klueber, K., Silveira, A. M., Haskell, B. S., & Farman, A. G. (2007) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2005.10.032 · Cited by 320
Clinical indications for digital imaging in dento‐alveolar trauma. Part 1: traumatic injuries
Cohenca, N., Simon, J. H., Roges, R., Morag, Y., & Malfaz, J. M. (2007) · Dental Traumatology · doi:10.1111/j.1600-9657.2006.00509.x · Cited by 209
“Studies have suggested that CBCT provides accurate and reliable linear measurements for reconstruction and imaging of dental and maxillofacial structures (8, 38, 39).”
BackgroundLoubele, M., Van Assche, N., Carpentier, K., Maes, F., Jacobs, R., van Steenberghe, D., & Suetens, P. (2008) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2007.05.004 · Cited by 208
Patcas, R., Müller, L., Ullrich, O., & Peltomäki, T. (2012) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2011.06.034 · Cited by 206
Damstra, J., Fourie, Z., Huddleston Slater, J. J. R., & Ren, Y. (2010) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2009.06.016 · Cited by 206
Working with DICOM craniofacial images
Grauer, D., Cevidanes, L. S. H., & Proffit, W. R. (2009) · American Journal of Orthodontics and Dentofacial Orthopedics · doi:10.1016/j.ajodo.2009.04.016 · Cited by 189
Clinical indications for digital imaging in dento‐alveolar trauma. Part 2: root resorption
Cohenca, N., Simon, J. H., Mathur, A., & Malfaz, J. M. (2007) · Dental Traumatology · doi:10.1111/j.1600-9657.2006.00546.x · Cited by 169
Assessment of bone segmentation quality of cone-beam CT versus multislice spiral CT: a pilot study
Loubele, M., Maes, F., Schutyser, F., Marchal, G., Jacobs, R., & Suetens, P. (2006) · Oral Surgery, Oral Medicine, Oral Pathology, Oral Radiology, and Endodontology · doi:10.1016/j.tripleo.2005.10.039 · Cited by 168
Contemporary imaging for the diagnosis and treatment of traumatic dental injuries: A review
Cohenca, N., & Silberman, A. (2017) · Dental Traumatology · doi:10.1111/edt.12339 · Cited by 75
Metadata
- Authors
- Marmulla, R., Wörtche, R., Mühling, J., & Hassfeld, S.
- Venue
- Dentomaxillofacial Radiology
- Publisher
- Oxford University Press (OUP)
- Published
- 2005-01
- Volume
- 34
- Issue
- 1
- Pages
- 28-31
- ISSN
- 0250-832X (ISSN-L)
- 1476-542X
- OpenAlex
- W2154324001
- Cited by
- 230
- References
- 6
- FWCI
- 16.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.