Comparative studies of speech processing strategies for cochlear implants
The DOI matches its Crossref record.
Abstract
A wide variety of speech processing strategies for multichannel auditory prostheses were compared in studies of two patients implanted with the UCSF electrode array. Each strategy was evaluated using tests of vowel and consonant confusions, with and without lipreading. Included among the strategies were the compressed analog processor of the present UCSF/Storz prosthesis and a group of interleaved pulses processors in which the amplitudes of nonsimultaneous pulses code the spectral variations of speech. For these patients, each with indications of poor nerve survival, test scores were significantly higher with the interleaved pulses processors. We believe this superior performance was a result of 1. the substantial release from channel interactions provided by nonsimultaneous stimuli and 2. a fast enough rotation among the channels to support adequate temporal and spectral resolution of perceived speech sounds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cochlear Implants: System Design, Integration, and Evaluation
Zeng, F.-G., Rebscher, S., Harrison, W., Sun, X., & Feng, H. (2008) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2008.2008250 · Cited by 878
“7(B) shows a functional block diagram of the “ -of- ” strategy, which was first described by Wilson and colleagues [68] and had been refined in subsequential development as the SPEAK and ACE strategies in the Nucleus devices [46], [65].”
MethodCochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Self-citationRole of Electrode Placement as a Contributor to Variability in Cochlear Implant Outcomes
Finley, C. C., Holden, T. A., Holden, L. K., Whiting, B. R., Chole, R. A., Neely, G. J., Hullar, T. E., & Skinner, M. W. (2008) · Otology & Neurotology · doi:10.1097/mao.0b013e318184f492 · Cited by 549
Self-citationCochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Self-citationThe cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
“The development of the n-of-m (Wilson et al., 1988), the continuous interleaved sampling (CIS) (Wilson et al., 1991), and spectral peak (SPEAK) (Skinner et al., 1994) strategies allowed improvements in CI performance.”
Speech Processing in Vocoder-Centric Cochlear Implants
Loizou, P. C. (2006) · Advances in Oto-Rhino-Laryngology · doi:10.1159/000094648 · Cited by 216
“Spectral-maxima strategy The spectral-maxima strategy implemented as the ACE (previously SPEAK) strategy on Cochlear Corporation devices [53]) and as the “n-of-m” strategy in other devices [54,55], has antecedents in the channel-picking vocoders of the 1950s [56] as well as Haskins Laboratories’ Pattern Playback speec…”
BackgroundMethodTemporal considerations for stimulating spiral ganglion neurons with cochlear implants.
Boulet, J., White, M., & Bruce, I. C. (2016) · Journal of the Association for Research in Otolaryngology · doi:10.1007/s10162-015-0545-5 · Cited by 114
“…processed by a peak-based strategy such as the Advanced Combined Encoder or Spectral Peak schemes (ACE, SPeak; Cochlear Corp., Sydney, Australia), or alternatively by the Continuous Interleaved Sampling strategy (CIS; (Wilson et al. 1988; Wilson et al. 1993)) mapped to eight neighboring electrodes.”
BackgroundMethodSelf-citation
Metadata
- Authors
- Wilson, B. S., Finley, C. C., Weber, B. A., White, M. W., Farmer, J. C., Wolford, R. D., Merzenich, M. M., Lawson, D. T., Kenan, P. D., & Schindler, R. A.
- Venue
- The Laryngoscope
- Publisher
- Wiley
- Published
- 1988-10
- Volume
- 98
- Issue
- 10
- Pages
- 1069-1077
- ISSN
- 0023-852X (ISSN-L)
- 1531-4995
- OpenAlex
- W1975672952
- Cited by
- 74
- References
- 0
- FWCI
- 0.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.