Concepts of Nanoparticle Dose Metric and Response Metric
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
In an attempt to identify the proper dose metric for particle toxicity, Wittmaack (2007) reanalyzed our dose–response data (Stoeger et al. 2006) and that of Oberdorster et al. (2005) on acute lung inflammation in rodents after instillation of various particle types. Out of particle BET surface area (SBET), particle number, joint length, and “geometric” surface area, Wittmaack concluded that particle number tends “to work best” as dose metric. We disagree with his conclusion. First, we wonder why Wittmaack (2007) used our data but ignored the data of Oberdorster et al. (2005) for the identification of the best dose metric. Figure 1 shows our dose–response data (in mice) for six different types of ultrafine carbonaceous particles (10–50 nm) and the data of Oberdorster et al. (2005) for fine (~ 250 nm) and ultrafine (~ 20 nm) TiO2 particles; we present the data for rats, which was reanalyzed by Wittmaack, and also the mouse data from Oberdorster et al. (2005). In Figure 1 the inflammatory response after 24 hr is expressed as the ratio of the polymorphonuclear leukocytes (PMNs) to lavaged cells, and the instilled dose is normalized to lung weight, because this facilitates interspecies comparison (Oberdorster et al. 2005). As suggested by Wittmaack (2007), we limit our discussion to the linear response regime [analogous to his Figure 3 (Wittmaack 2007)]. For this data set, the linear correlation coefficient R2 is 0.46, 0.51, 0.67, and 0.72 for particle number, joint length, “geometric” surface area, and SBET, respectively. Particularly, the response to the fine particles, as represented by the red fit line (almost identical to the y-axis in Figure 1A), is not adequately described by particle number (Figure 1A), whereas SBET works well for all particle sizes (Figure 1B). Although we do not suggest SBET as a “universal” dose metric (chemistry, charge, etc., are also relevant), we conclude that for the dose metric examined here, SBET is the most relevant dose parameter. Wittmaack’s preference for particle number appears to be the result of an unsubstantiated restriction of his analysis to our data, which is dominated by particles in a relatively narrow size regime between about 10 and 25 nm. Figure 1 Acute pulmonary inflammatory response (PMNs) to TiO2 [Oberdorster et al. 2005; Figure 4 and Figure S-2 (Supplemental Material available online at http://ehp.niehs.nih.gov/members/2005/7339/supplemental.pdf)] and carbonaceous particles (Stoeger ... Second, all investigated dose parameters (except SBET) depend on accurate determination of the mean particle diameter, , requiring tedious and potentially uncertain single particle analysis. Wittmaack (2007) acknowledged potentially large errors in for particles below about 20 nm [i.e., for four out of our six (carbonaceous) particle types]. Being aware of these limitations, we intentionally reported only a range of observed particle diameters (not ) in our article (Stoeger et al. 2006). Unfortunately, Wittmaack did not discuss his conclusions in light of these methodologic limitations. Especially for the smallest particle type (here spark-generated carbon particles with = 9.8 nm), preferential particle selection is likely to result in an overestimation of . Assuming a 25% sizing error, this yields a systematic error of + 100% in particle number (~ −3), which shifts these data points far away from the linear fit line (see error bars in Figure 1A). In contrast, SBET requires only a single measurement on an aliquot of the administered particles; that is, it is not adversely affected by problems associated with single particle analysis, and it adequately accounts for potentially important particle characteristics such as particle morphology and surface porosity. In summary, we do not agree with the dose–response interpretation of our data by Wittmaack (2007). We conclude that SBET (and not particle number) is the best dose parameter, accounting for 72% (R2 = 0.72) of the observed inflammatory response for both data sets spanning a size range of 10–250 nm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Toxic potential of materials at the nanolevel
Nel, A., Xia, T., Mädler, L., & Li, N. (2006) · Science · doi:10.1126/science.1114397 · Cited by 9,324
Nanotoxicology: An Emerging Discipline Evolving from Studies of Ultrafine Particles
Oberdörster, G., Oberdörster, E., & Oberdörster, J. (2005) · Environmental Health Perspectives · doi:10.1289/ehp.7339 · Cited by 7,891 · cited 4×
“Wittmaack (2007) did not agree with our suggestion (Oberdörster et al. 2005) that particle surface area is a more appropriate dose metric than particle mass or particle number when evaluating dose–response relationships of nanoparticle-induced pulmonary inflammation.”
InfluentialSelf-citationLong, T. C., Saleh, N., Tilton, R. D., Lowry, G. V., & Veronesi, B. (2006) · Environmental Science & Technology · doi:10.1021/es060589n · Cited by 870 · cited 1×
“…specific density of TiO2 (anatase) and a spherical primary particle size of 20 nm. BET surface area for this TiO2 (Degussa P25) has been measured independently by a number of investigators, including our group (Jwo et al. 2005; Long et al. 2006; Wahl et al. 2005), and ranges between 48 and 55 m2/g.”
Nanoparticles: Health Effects—Pros and Cons
Gwinn, M. R., & Vallyathan, V. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.8871 · Cited by 571
Stoeger, T., Reinhard, C., Takenaka, S., Schroeppel, A., Karg, E., Ritter, B., Heyder, J., & Schulz, H. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.8266 · Cited by 486
Cardiovascular Effects of Nickel in Ambient Air
Lippmann, M., Ito, K., Hwang, J.-S., Maciejczyk, P., & Chen, L.-C. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9150 · Cited by 343 · cited 14×
“Furthermore, Inco’s stack emissions are characteristic and distinct from the CAPs composition reported by Lippmann et al. (2006).”
InfluentialHealth implications of nanoparticles
Kreyling, W. G., Semmler-Behnke, M., & Möller, W. (2006) · Journal of Nanoparticle Research · doi:10.1007/s11051-005-9068-z · Cited by 300
Wittmaack, K. (2007) · Environmental Health Perspectives · doi:10.1289/ehp.9254 · Cited by 280
Photodegradation of Congo Red catalyzed by nanosized TiO2
Wahi, R. K., Yu, W. W., Liu, Y., Mejia, M. L., Falkner, J. C., Nolte, W., & Colvin, V. L. (2005) · Journal of Molecular Catalysis A: Chemical · doi:10.1016/j.molcata.2005.07.034 · Cited by 191
Genetic susceptibility to nickel-induced acute lung injury
Prows, D. R., McDowell, S. A., Aronow, B. J., & Leikauf, G. D. (2003) · Chemosphere · doi:10.1016/s0045-6535(02)00710-5 · Cited by 28 · cited 1×
“It should be noted that healthy B6C3F1 mice were exposed in this study, and that healthy B6 mice had much greater survival times than seven other inbred mice strains when exposed to nickel sulfate by Prows et al. (2003).”
Photodecomposition of gaseous toluene using TiO 2 prepared by SANSS
Jwo, C. S., Tien, D., Chen, L.-C., et al. (2005) · Journal of Physics Conference Series · doi:10.1088/1742-6596/13/1/101 · Cited by 1 · cited 1×
“…specific density of TiO2 (anatase) and a spherical primary particle size of 20 nm. BET surface area for this TiO2 (Degussa P25) has been measured independently by a number of investigators, including our group (Jwo et al. 2005; Long et al. 2006; Wahl et al. 2005), and ranges between 48 and 55 m2/g.”
Cited by
Nanomaterials in the environment: Behavior, fate, bioavailability, and effects
Klaine, S. J., Alvarez, P. J. J., Batley, G. E., Fernandes, T. F., Handy, R. D., Lyon, D. Y., Mahendra, S., McLaughlin, M. J., & Lead, J. R. (2008) · Environmental Toxicology and Chemistry · doi:10.1897/08-090.1 · Cited by 2,764
Nanomedicine—Challenge and Perspectives
Riehemann, K., Schneider, S. W., Luger, T. A., Godin, B., Ferrari, M., & Fuchs, H. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200802585 · Cited by 1,305
The ecotoxicology and chemistry of manufactured nanoparticles
Handy, R. D., von der Kammer, F., Lead, J. R., Hassellöv, M., Owen, R., & Crane, M. (2008) · Ecotoxicology · doi:10.1007/s10646-008-0199-8 · Cited by 916
Handy, R. D., Owen, R., & Valsami-Jones, E. (2008) · Ecotoxicology · doi:10.1007/s10646-008-0206-0 · Cited by 888
Review of health safety aspects of nanotechnologies in food production
Bouwmeester, H., Dekkers, S., Noordam, M. Y., Hagens, W. I., Bulder, A. S., de Heer, C., ten Voorde, S. E. C. G., Wijnhoven, S. W. P., Marvin, H. J. P., & Sips, A. J. A. M. (2009) · Regulatory Toxicology and Pharmacology · doi:10.1016/j.yrtph.2008.10.008 · Cited by 812
Metadata
- Authors
- Oberdörster, G., Oberdörster, E., & Oberdörster, J.
- Venue
- Environmental Health Perspectives
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-06
- Volume
- 115
- Issue
- 6
- Pages
- A290-A290
- ISSN
- 0091-6765 (ISSN-L)
- 1552-9924
- OpenAlex
- W4255480785
- Cited by
- 210
- References
- 11
- FWCI
- 8.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.