CoChat
Cited by 247

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Relationship between Radial and Central Arterial Pulse Wave and Evaluation of Central Aortic Pressure Using the Radial Arterial Pulse Wave

Open access
TAKAZAWA, Kenji, KOBAYASHI, Hideyuki, SHINDO, Naohisa, TANAKA, Nobuhiro, YAMASHINA, Akira · 2007 · Hypertension Research

Abstract

Since a decrease of central aortic pressure contributes to the prevention of cardiovascular events, simple measurement of not only brachial blood pressure but also central aortic pressure may be useful in the prevention and treatment of cardiovascular diseases. In this study, we simultaneously measured radial artery pulse waves non-invasively and ascending aortic pressure invasively, before and after the administration of nicorandil. We then compared changes in central aortic pressure and radial arterial blood pressure calibrated with brachial blood pressure in addition to calculating the augmentation index (AI) at the aorta and radial artery. After nicorandil administration, the reduction in maximal systolic blood pressure in the aorta (Deltaa-SBP) was -14+/-15 mmHg, significantly larger than that in early systolic pressure in the radial artery (Deltar-SBP) (-9+/-12 mmHg). The reduction in late systolic blood pressure in the radial artery (Deltar-SBP2) was -15+/-14 mmHg, significantly larger than Deltar-SBP, but not significantly different from Deltaa-SBP. There were significant relationships between Deltaa-SBP and Deltar-SBP (r=0.81, p<0.001), and between Deltaa-SBP and Deltar-SBP2 (r=0.91, p<0.001). The slope of the correlation regression line with Deltar-SBP2 (0.83) was larger and closer to 1 than that with Deltar-SBP (0.63), showing that the relationship was close to 1:1. Significant correlations were obtained between aortic AI (a-AI) and radial AI (r-AI) (before nicorandil administration: r=0.91, p<0.001; after administration: r=0.70, p<0.001). These data suggest that the measurement of radial artery pulse wave and observation of changes in the late systolic blood pressure in the radial artery (r-SBP2) in addition to the ordinary measurement of brachial blood pressure may enable a more accurate evaluation of changes in maximal systolic blood pressure in the aorta (a-SBP).

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1291/hypres.30.219

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 247

Metadata

Authors
TAKAZAWA, K., KOBAYASHI, H., SHINDO, N., TANAKA, N., & YAMASHINA, A.
Venue
Hypertension Research
Published
2007
Volume
30
Issue
3
Pages
219-228
ISSN
  • 0916-9636 (ISSN-L)
  • 1348-4214
OpenAlex
W1985730517
Cited by
247
References
3
FWCI
10.80
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.