The learning curve associated with robotic-arm assisted unicompartmental knee arthroplasty: a prospective cohort study
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Aims: The primary aim of this study was to determine the surgical team’s learning curve for introducing robotic-arm assisted unicompartmental knee arthroplasty (UKA) into routine surgical practice. The secondary objective was to compare accuracy of implant positioning in conventional jig-based UKA versus robotic-arm assisted UKA. Patients and Methods: This prospective single-surgeon cohort study included 60 consecutive conventional jig-based UKAs compared with 60 consecutive robotic-arm assisted UKAs for medial compartment knee osteoarthritis. Patients undergoing conventional UKA and robotic-arm assisted UKA were well-matched for baseline characteristics including a mean age of 65.5 years (sd 6.8) vs 64.1 years (sd 8.7), (p = 0.31); a mean body mass index of 27.2 kg.m2 (sd 2.7) vs 28.1 kg.m2 (sd 4.5), (p = 0.25); and gender (27 males: 33 females vs 26 males: 34 females, p = 0.85). Surrogate measures of the learning curve were prospectively collected. These included operative times, the Spielberger State-Trait Anxiety Inventory (STAI) questionnaire to assess preoperative stress levels amongst the surgical team, accuracy of implant positioning, limb alignment, and postoperative complications. Results: Robotic-arm assisted UKA was associated with a learning curve of six cases for operating time (p < 0.001) and surgical team confidence levels (p < 0.001). Cumulative robotic experience did not affect accuracy of implant positioning (p = 0.52), posterior condylar offset ratio (p = 0.71), posterior tibial slope (p = 0.68), native joint line preservation (p = 0.55), and postoperative limb alignment (p = 0.65). Robotic-arm assisted UKA improved accuracy of femoral (p < 0.001) and tibial (p < 0.001) implant positioning with no additional risk of postoperative complications compared to conventional jig-based UKA. Conclusion: Robotic-arm assisted UKA was associated with a learning curve of six cases for operating time and surgical team confidence levels but no learning curve for accuracy of implant positioning. Cite this article: Bone Joint J 2018;100-B:1033–42.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marteau, T. M., & Bekker, H. (1992) · British Journal of Clinical Psychology · doi:10.1111/j.2044-8260.1992.tb00997.x · Cited by 3,238
GRADING OF PATIENTS FOR SURGICAL PROCEDURES
Saklad, M. (1941) · Anesthesiology · doi:10.1097/00000542-194105000-00004 · Cited by 1,956
Rapid recovery after Oxford unicompartmental arthroplasty through a short incision
Price, A. J., Webb, J., Topf, H., Dodd, C. A. F., Goodfellow, J. W., & Murray, D. W. (2001) · The Journal of Arthroplasty · doi:10.1054/arth.2001.25552 · Cited by 399
Cobb, J., Henckel, J., Gomes, P., Harris, S., Jakopec, M., Rodriguez, F., Barrett, A., & Davies, B. (2006) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.88b2.17220 · Cited by 333
Collier, M. B., Eickmann, T. H., Sukezaki, F., McAuley, J. P., & Engh, G. A. (2006) · The Journal of Arthroplasty · doi:10.1016/j.arth.2006.04.012 · Cited by 223
Robotic Arm-assisted UKA Improves Tibial Component Alignment: A Pilot Study
Lonner, J. H., John, T. K., & Conditt, M. A. (2010) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-009-0977-5 · Cited by 215
Blyth, M., Anthony, I., Rowe, P. J., Banger, M. S., MacLean, A., & Jones, B. G. (2017) · Bone and Joint Research · doi:10.1302/2046-3758.611.bjr-2017-0060.r1 · Cited by 159
CUMULATIVE SUM TECHNIQUES FOR SURGEONS: A BRIEF REVIEW
Yap, C., Colson, M. E., & Watters, D. A. (2007) · ANZ Journal of Surgery · doi:10.1111/j.1445-2197.2007.04155.x · Cited by 154
Seon, J. K., & Song, E. K. (2006) · The Journal of Arthroplasty · doi:10.1016/j.arth.2005.08.024 · Cited by 89
Cited by
Kayani, B., Konan, S., Huq, S. S., Tahmassebi, J., & Haddad, F. S. (2019) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-018-5138-5 · Cited by 338
Self-citationAlignment in total knee arthroplasty: what’s in a name?
Oussedik, S., Abdel, M. P., Victor, J., Pagnano, M. W., & Haddad, F. S. (2020) · The Bone & Joint Journal · doi:10.1302/0301-620x.102b3.bjj-2019-1729 · Cited by 289
Self-citationPersonalized alignment in total knee arthroplasty: current concepts
Lustig, S., Sappey-Marinier, E., Fary, C., Servien, E., Parratte, S., & Batailler, C. (2021) · SICOT-J · doi:10.1051/sicotj/2021021 · Cited by 226
“The precision offered by robotic assistance may make achieving non-neutral alignment targets more reproducible [41], reducing the risk of missing the target and producing significant outliers of the limb alignment.”
Background
Metadata
- Authors
- Kayani, B., Konan, S., Pietrzak, J. R. T., Huq, S. S., Tahmassebi, J., & Haddad, F. S.
- Venue
- The Bone & Joint Journal
- Published
- 2018-08
- Volume
- 100-B
- Issue
- 8
- Pages
- 1033-1042
- ISSN
- 2049-4394 (ISSN-L)
- 2049-4408
- OpenAlex
- W2886693097
- Cited by
- 159
- References
- 9
- FWCI
- 17.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.