The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning
Open accessAbstract
PURPOSE: The primary objective of this study was to determine the surgical team's learning curve for robotic-arm assisted TKA through assessments of operative times, surgical team comfort levels, accuracy of implant positioning, limb alignment, and postoperative complications. Secondary objectives were to compare accuracy of implant positioning and limb alignment in conventional jig-based TKA versus robotic-arm assisted TKA. METHODS: This prospective cohort study included 60 consecutive conventional jig-based TKAs followed by 60 consecutive robotic-arm assisted TKAs performed by a single surgeon. Independent observers recorded surrogate markers of the learning curve including operative times, stress levels amongst the surgical team using the state-trait anxiety inventory (STAI) questionnaire, accuracy of implant positioning, limb alignment, and complications within 30 days of surgery. Cumulative summation (CUSUM) analyses were used to assess learning curves for operative time and STAI scores in robotic TKA. RESULTS: Robotic-arm assisted TKA was associated with a learning curve of seven cases for operative times (p = 0.01) and surgical team anxiety levels (p = 0.02). Cumulative robotic experience did not affect accuracy of implant positioning (n.s.) limb alignment (n.s.) posterior condylar offset ratio (n.s.) posterior tibial slope (n.s.) and joint line restoration (n.s.). Robotic TKA improved accuracy of implant positioning (p < 0.001) and limb alignment (p < 0.001) with no additional risk of postoperative complications compared to conventional manual TKA. CONCLUSION: Implementation of robotic-arm assisted TKA led to increased operative times and heightened levels of anxiety amongst the surgical team for the initial seven cases but there was no learning curve for achieving the planned implant positioning. Robotic-arm assisted TKA improved accuracy of implant positioning and limb alignment compared to conventional jig-based TKA. The findings of this study will enable clinicians and healthcare professionals to better understand the impact of implementing robotic TKA on the surgical workflow, assist the safe integration of this procedure into surgical practice, and facilitate theatre planning and scheduling of operative cases during the learning phase. LEVEL OF EVIDENCE: II.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Marteau, T. M., & Bekker, H. (1992) · British Journal of Clinical Psychology · doi:10.1111/j.2044-8260.1992.tb00997.x · Cited by 3,238
The John Insall Award: Patient Expectations Affect Satisfaction with Total Knee Arthroplasty
Noble, P. C., Conditt, M. A., Cook, K. F., & Mathis, K. B. (2006) · Clinical Orthopaedics and Related Research · doi:10.1097/01.blo.0000238825.63648.1e · Cited by 1,127
Coronal alignment after total knee replacement
Jeffery, R., Morris, R., & Denham, R. (1991) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.73b5.1894655 · Cited by 1,100
Postoperative Alignment of Total Knee Replacement Its Effect on Survival
RITTER, M. A., FARIS, P. M., KEATING, E. M., & MEDING, J. B. (1994) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-199402000-00021 · Cited by 1,008
Baker, P. N., van der Meulen, J. H., Lewsey, J., & Gregg, P. J. (2007) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.89b7.19091 · Cited by 975
Parratte, S., Pagnano, M. W., Trousdale, R. T., & Berry, D. J. (2010) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/jbjs.i.01398 · Cited by 808
Song, E.-K., Seon, J.-K., Yim, J.-H., Netravali, N. A., & Bargar, W. L. (2013) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-012-2407-3 · Cited by 447
Song, E., Seon, J., Park, S., Jung, W. B., Park, H., & Lee, G. W. (2011) · Knee Surgery, Sports Traumatology, Arthroscopy · doi:10.1007/s00167-011-1400-9 · Cited by 268
The Learning Curve Associated with Robotic Total Knee Arthroplasty
Sodhi, N., Khlopas, A., Piuzzi, N., Sultan, A., Marchand, R., Malkani, A., & Mont, M. (2018) · The Journal of Knee Surgery · doi:10.1055/s-0037-1608809 · Cited by 197
Robot-assisted Total Knee Arthroplasty
Bellemans, J., Vandenneucker, H., & Vanlauwe, J. (2007) · Clinical Orthopaedics & Related Research · doi:10.1097/blo.0b013e318126c0c0 · Cited by 178
Metadata
- Authors
- Kayani, B., Konan, S., Huq, S. S., Tahmassebi, J., & Haddad, F. S.
- Venue
- Knee Surgery, Sports Traumatology, Arthroscopy
- Publisher
- Wiley
- Published
- 2018-09-17
- Volume
- 27
- Issue
- 4
- Pages
- 1132-1141
- ISSN
- 0942-2056 (ISSN-L)
- 1433-7347
- OpenAlex
- W2891088257
- Cited by
- 338
- References
- 13
- FWCI
- 19.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning. https://app.cochat.ai/papers/10.1007/s00167-018-5138-5
- The paper
- Kayani, B., Konan, S., Huq, S. S., Tahmassebi, J., & Haddad, F. S. (2019). Robotic-arm assisted total knee arthroplasty has a learning curve of seven cases for integration into the surgical workflow but no learning curve effect for accuracy of implant positioning. Knee Surgery, Sports Traumatology, Arthroscopy. https://doi.org/10.1007/s00167-018-5138-5
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.