Cited by 268Hip disorders and treatmentsOrthopaedic implants and arthroplastyOsteoarthritis Treatment and Mechanisms

Contact pressures in the human hip joint

Afoke, NY, Byers, PD, Hutton, WC·1987·The Journal of Bone and Joint Surgery. British volume

Abstract

The pressure distribution between the cartilaginous surfaces in the human hip joint was measured using pressure-sensitive film. Five cadaveric hip joints (aged between 58 and 87 years) were measured at three positions and loads, representing three instants in the stance phase of the walking cycle. The pressure distribution was not uniform, indicating that the cartilage did not, to any great extent, distribute the applied load. The maximum pressures recorded were about 10 MN/m2. The anterosuperior surface of the cartilage was identified as an area of high pressure.

Integrity signals

Registry

Crossref · 10.1302/0301-620x.69b4.3611154

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Local pressures up to ca. 20 MPa have been measured in hip joints, and mean pressure during peak of normal walking cycle is ca. 5 MPa.

    “Through the use of implants with pressure sensors, local pressures up to ca. 20 MPa (ca. 200 atm) have been measured in hip joints [102, 103], while the mean pressure during the peak of a normal walking cycle is ca. 5 MPa.”

    From Hydration lubrication (2013) · cites this paper as [102]

Cited by

Sorted by citations

Authors
Afoke, N., Byers, P., & Hutton, W.
Venue
The Journal of Bone and Joint Surgery. British volume
Published
1987-08
Volume
69-B
Issue
4
Pages
536-541
ISSN
  • 0301-620X (ISSN-L)
  • 2044-5377
OpenAlex
W2242048740
Cited by
268
References
0
Citations by year
2026: 4 · 2025: 5 · 2024: 8 · 2023: 7 · 2022: 6 · 2021: 9 · 2020: 12 · 2019: 3 · 2018: 9 · 2017: 9 · 2016: 9 · 2015: 7 · 2014: 9 · 2013: 23 · 2012: 8
FWCI
1.62
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Bone and Joint Surgery - British Volume (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Surgery › Hip disorders and treatments
  • Health Sciences › Medicine › Surgery › Orthopaedic implants and arthroplasty
  • Health Sciences › Medicine › Rheumatology › Osteoarthritis Treatment and Mechanisms
Keywords
hip joint, contact pressure, articular cartilage, pressure distribution, load distribution, cadaveric hip, pressure-sensitive film, cartilage loading
MeSH terms
Aged, Cartilage, Articular, Female, Hip Joint, Humans, Locomotion, Male, Middle Aged, Posture, Pressure, Stress, Mechanical

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review