Osteolytic changes accompanying degradation of absorbable fracture fixation implants
Abstract
We analysed the radiographs of 67 patients with displaced malleolar fractures treated by open reduction and internal fixation using absorbable polyglycolide rods. Seventeen patients developed a discharging inflammatory foreign-body reaction, a complication unique to these fixation devices. In 34 patients ovoid osteolytic foci, usually 5 to 10 mm in diameter, appeared within the implant channels six to 12 weeks after the operation. The same lesion occurred in 14 of the 17 patients who developed a foreign-body reaction, whereas only 20 out of the 50 patients with an uneventful course showed osteolytic areas (p less than 0.01). In patients with a foreign-body reaction the osteolytic foci tended to occur in the deepest parts of the implant channels. However, after one year the normal structure of the bone was restored.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In clinical studies where PGA was used as fracture fixation, foreign-body responses or osteolytic reactions have been reported.
“In clinical studies where PGA was used as fracture fixation, foreign-body responses or osteolytic reactions have been reported”
From Biodegradable synthetic polymers for tissue engineering (2003) · cites this paper as Böstman, 1991
Cited by
Sorted by citations
Biodegradable synthetic polymers for tissue engineering
CSIRO Molecular Science, B. 1., & Gunatillake, P. (2003) · European Cells and Materials · doi:10.22203/ecm.v005a01 · Cited by 1,765 · see citing works
Recent Developments in Ring Opening Polymerization of Lactones for Biomedical Applications
Albertsson, A.-C., & Varma, I. K. (2003) · Biomacromolecules · doi:10.1021/bm034247a · Cited by 1,582 · see citing works
Preliminary results of an absorbable interference screw
Barber, F. A., Elrod, B. F., McGuire, D. A., & Paulos, L. E. (1995) · Arthroscopy · doi:10.1016/0749-8063(95)90129-9 · Cited by 178 · see citing works
Elevated temperature degradation of a 50:50 copolymer of PLA-PGA
Agrawal, C. M., Huang, D., Schmitz, J. P., & Athanasiou, K. A. (1997) · Tissue Engineering · doi:10.1089/ten.1997.3.345 · Cited by 120 · see citing works
Athanasiou, K. A., Schmitz, J. P., & Agrawal, C. M. (1998) · Tissue Engineering · doi:10.1089/ten.1998.4.53 · Cited by 110 · see citing works
Yildirimer, L., & Seifalian, A. M. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2014.04.014 · Cited by 98 · see citing works
In vivo comparison of a metal versus a biodegradable suture anchor <sup>1</sup>
DeJong, L. E. S., DeBerardino, L. T. M., Brooks, D. E., & Judson, K. (2004) · Arthroscopy · doi:10.1016/j.arthro.2004.03.008 · Cited by 53 · see citing works
- Authors
- Bostman, O.
- Affiliations
- Helsinki University Central Hospital, Finland.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1991-07
- Volume
- 73-B
- Issue
- 4
- Pages
- 679-682
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2153688535
- Cited by
- 294
- References
- 0
- Citations by year
- 2026: 2 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 3 · 2020: 8 · 2019: 12 · 2018: 3 · 2017: 4 · 2016: 8 · 2015: 6 · 2014: 10 · 2013: 6 · 2012: 8
- FWCI
- 5.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Bone and Joint Surgery - British Volume (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Epidemiology › Bone fractures and treatments
- Health Sciences › Medicine › Orthopedics and Sports Medicine › Foot and Ankle Surgery
- Health Sciences › Medicine › Surgery › Facial Trauma and Fracture Management
- Keywords
- osteolysis, absorbable implants, fracture fixation, foreign body reaction, ankle fractures, implant degradation, bone regeneration
- MeSH terms
- Adult, Biodegradation, Environmental, Fibula, Follow-Up Studies, Foreign-Body Reaction, Fracture Fixation, Internal, Humans, Osteolysis, Polyglycolic Acid, Polymers, Radiography, Tibial Fractures, Ankle Injuries, Prostheses and Implants, Fractures, Bone
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review