Cited by 294Bone fractures and treatmentsFoot and Ankle SurgeryFacial Trauma and Fracture Management

Osteolytic changes accompanying degradation of absorbable fracture fixation implants

Bostman, OM·1991·The Journal of Bone and Joint Surgery. British volume

Abstract

We analysed the radiographs of 67 patients with displaced malleolar fractures treated by open reduction and internal fixation using absorbable polyglycolide rods. Seventeen patients developed a discharging inflammatory foreign-body reaction, a complication unique to these fixation devices. In 34 patients ovoid osteolytic foci, usually 5 to 10 mm in diameter, appeared within the implant channels six to 12 weeks after the operation. The same lesion occurred in 14 of the 17 patients who developed a foreign-body reaction, whereas only 20 out of the 50 patients with an uneventful course showed osteolytic areas (p less than 0.01). In patients with a foreign-body reaction the osteolytic foci tended to occur in the deepest parts of the implant channels. However, after one year the normal structure of the bone was restored.

Integrity signals

Registry

Crossref · 10.1302/0301-620x.73b4.1649195

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • In clinical studies where PGA was used as fracture fixation, foreign-body responses or osteolytic reactions have been reported.

    “In clinical studies where PGA was used as fracture fixation, foreign-body responses or osteolytic reactions have been reported”

    From Biodegradable synthetic polymers for tissue engineering (2003) · cites this paper as Böstman, 1991

Cited by

Sorted by citations

Authors
Bostman, O.
Affiliations
Helsinki University Central Hospital, Finland.
Venue
The Journal of Bone and Joint Surgery. British volume
Published
1991-07
Volume
73-B
Issue
4
Pages
679-682
ISSN
  • 0301-620X (ISSN-L)
  • 2044-5377
OpenAlex
W2153688535
Cited by
294
References
0
Citations by year
2026: 2 · 2024: 1 · 2023: 1 · 2022: 2 · 2021: 3 · 2020: 8 · 2019: 12 · 2018: 3 · 2017: 4 · 2016: 8 · 2015: 6 · 2014: 10 · 2013: 6 · 2012: 8
FWCI
5.71
Type
journal article
Language
en
Open access
closed
Locations
  • Journal of Bone and Joint Surgery - British Volume (publishedVersion)
  • PubMed (publishedVersion)
Topics
  • Health Sciences › Medicine › Epidemiology › Bone fractures and treatments
  • Health Sciences › Medicine › Orthopedics and Sports Medicine › Foot and Ankle Surgery
  • Health Sciences › Medicine › Surgery › Facial Trauma and Fracture Management
Keywords
osteolysis, absorbable implants, fracture fixation, foreign body reaction, ankle fractures, implant degradation, bone regeneration
MeSH terms
Adult, Biodegradation, Environmental, Fibula, Follow-Up Studies, Foreign-Body Reaction, Fracture Fixation, Internal, Humans, Osteolysis, Polyglycolic Acid, Polymers, Radiography, Tibial Fractures, Ankle Injuries, Prostheses and Implants, Fractures, Bone

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review