Axial movement and tibial fractures. A controlled randomised trial of treatment
The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Diaphyseal fractures of the tibia in 80 patients were treated by external skeletal fixation using a unilateral frame, either in a fixed mode or in a mode which allowed the application of a small amount of predominantly axial micromovement. Patients were allocated to each regime by random selection. Fracture healing was assessed clinically, radiologically and by measurement of the mechanical stiffness of the fracture. Both clinical and mechanical healing were enhanced in the group subjected to micromovement, compared to those treated with frames in a fixed mode possessing an overall stiffness similar to that of others in common clinical use. The differences in healing time were statistically significant and independently related to the treatment method. There was no difference in complication rates between treatment groups.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
GUSTILO, R. B., & ANDERSON, J. T. (2002) · The Journal of Bone and Joint Surgery-American Volume · doi:10.2106/00004623-200204000-00029 · Cited by 2,789
The influence of induced micromovement upon the healing of experimental tibial fractures
Goodship, A., & Kenwright, J. (1985) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.67b4.4030869 · Cited by 903
Self-citationControlled mechanical stimulation in the treatment of tibial fractures
KENWRIGHT, J., & GOODSHIP, A. E. (1989) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198904000-00006 · Cited by 373
Self-citationThe treatment of fractures with a dynamic axial fixator
De Bastiani, G., Aldegheri, R., & Renzi Brivio, L. (1984) · The Journal of Bone and Joint Surgery. British volume · doi:10.1302/0301-620x.66b4.6746689 · Cited by 306
Classification of Tibial Shaft Fractures and Correlation with Results after Rigid Internal Fixation
JOHNER, R., & WRUHS, O. (1983) · Clinical Orthopaedics and Related Research · doi:10.1097/00003086-198309000-00003 · Cited by 288
Fracture healing in rat femora as affected by functional weight-bearing
Sarmiento, A., Schaeffer, J., Beckerman, L., Latta, L., & Enis, J. (1977) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-197759030-00014 · Cited by 226
EFFECT OF CONTROLLED AXIAL MICROMOVEMENT ON HEALING OF TIBIAL FRACTURES
KENWRIGHT, J., Goodship, A. E., Kelly, D. J., Newman, J. H., Harris, J. D., Richardson, J. B., Evans, M., Spriggins, A. J., Burrough, S., & ROWLEY, D. I. (1986) · The Lancet · doi:10.1016/s0140-6736(86)92196-3 · Cited by 144
Self-citationDesign and performance of a fracture monitoring transducer
Evans, M., KENWRIGHT, J., & Cunningham, J. L. (1988) · Journal of Biomedical Engineering · doi:10.1016/0141-5425(88)90028-3 · Cited by 63
Self-citationThe early healing of tibial osteotomies stabilized by one-plane or two-plane external fixation
Williams, E. A., Rand, J. A., An, K., Chao, E. Y. S., & Kelly, P. J. (1987) · Journal of Bone and Joint Surgery · doi:10.2106/00004623-198769030-00006 · Cited by 60
Cited by
Szmukler-Moncler, S., Salama, H., Reingewirtz, Y., & Dubruille, J. H. (1998) · Journal of Biomedical Materials Research · doi:10.1002/(sici)1097-4636(199822)43:2<192::aid-jbm14>3.0.co;2-k · Cited by 794
Enhancement of fracture-healing.
Einhorn, T. A. (1995) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199506000-00016 · Cited by 772
Biomechanical testing of the LCP – how can stability in locked internal fixators be controlled?
Stoffel, K., Dieter, U., Stachowiak, G., Gächter, A., & Kuster, M. S. (2003) · Injury · doi:10.1016/j.injury.2003.09.021 · Cited by 657
Shear movement at the fracture site delays healing in a diaphyseal fracture model
Augat, P., Burger, J., Schorlemmer, S., Henke, T., Peraus, M., & Claes, L. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(03)00098-6 · Cited by 369
Risk factors contributing to fracture non-unions
Calori, G. M., Albisetti, W., Agus, A., Iori, S., & Tagliabue, L. (2007) · Injury · doi:10.1016/s0020-1383(07)80004-0 · Cited by 290
Metadata
- Authors
- Kenwright, J., Richardson, J., Cunningham, J., White, S., Goodship, A., Adams, M., Magnussen, P., & Newman, J.
- Venue
- The Journal of Bone and Joint Surgery. British volume
- Published
- 1991-07
- Volume
- 73-B
- Issue
- 4
- Pages
- 654-659
- ISSN
- 0301-620X (ISSN-L)
- 2044-5377
- OpenAlex
- W2182108454
- Cited by
- 295
- References
- 9
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.